WaterVerge

Is Wayne Twp.-1614, NJ Tap Water Safe to Drink?

Graded B+ — but PFOA was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

55K residents served 1 water system PWSID: NJ1614001
Overall Score
84.8 / 100
Violations
8 active
Last Updated
May 2026
Source
Purchased surface water
#54 of 435 in New Jersey Top 36% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
B+GRADE
Water Quality Grade
84.8/100
waterverge.com
B+ 84.8/100

Wayne Twp.-1614, NJ — Water Quality Report

Wayne Twp.-1614's drinking water received a grade of B+ (84.8 out of 100), indicating good water quality. The city's 1 water system serves approximately 55,000 residents using purchased surface water.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound, with levels exceeding EPA maximum contaminant levels in the water supply.

The system has 22 violations on record, including 1 health-based violation. 8 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Wayne Twp.-1614's water

Wayne Twp.-1614 ranks #54 out of 435 cities in New Jersey for water quality, placing it above average in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

Of particular concern: PFAS "forever chemical" levels exceed the 2024 EPA maximum contaminant levels. These synthetic compounds don't break down naturally and require specialized filtration such as reverse osmosis or granular activated carbon.

Hexavalent chromium (chromium-6) was detected at 0.04 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

Quality Breakdown

Water quality score

See methodology →
84.8 out of 100 Grade B+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
41.1/45
A
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.0 ppb (90th percentile).
Contaminants
14.7/20
C
1 PFAS compound detected.
Compliance
5/10
D
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Purchased surface water.
Water Safety

Is Wayne Twp.-1614, NJ water safe to drink?

Concerns Identified

Wayne Twp.-1614's drinking water has significant quality concerns based on EPA testing data. With a grade of B+ (84.8/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 55,000 residents using surface water (rivers, lakes, or reservoirs).

8
Active Violations
0.0 ppb
Lead (90th %ile)
1 compound
PFAS Detected
10 events
Disaster History

Recent water quality updates for Wayne Twp.-1614

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

PFAS levels exceed EPA maximum contaminant levels. Reverse osmosis or activated carbon filtration recommended.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Wayne Twp.-1614's water quality assessment. Grade: B+ (84.8/100).

Disaster
REMNANTS OF HURRICANE IDA

Federal disaster declaration (FEMA DR-4614). Hurricane event — may have impacted local water infrastructure.

Disaster
REMNANTS OF HURRICANE IDA

Federal disaster declaration (FEMA DR-3573). Hurricane event — may have impacted local water infrastructure.

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Wayne Twp.-1614's water supply.

Lead Within Limits
Detected: 0.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (1 compound) Exceeds Limit
Detected: Highest: PFOA at 0.0049 µg/L Limit: 0.004 µg/L (EPA MCL)

PFAS "forever chemicals" exceed EPA maximum contaminant levels. Reverse osmosis or granular activated carbon filtration strongly recommended.

Violation history

Wayne Twp.-1614's water system has 22 total violations on record, including 1 health-based violation. 8 remain unresolved. 1 violation was issued in the last 5 years.

OtherMRRPTTT
Most recent violations:
Jul 2021 Consumer Confidence Rule Open
Jul 2020 Consumer Confidence Rule Open
Oct 2019 Lead and Copper Rule Open
Dec 2018 Lead and Copper Rule Open
Apr 2018 Lead and Copper Rule Open

Flood & environmental risk

Passaic County has experienced 10 federally declared disasters since 1984. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Whippany River Near Pine Brook, Passaic River At Pine Brook, Passaic R At Horse Neck Bridge Near Pine Bk, Pequannock River At Riverdale, West Brook Near Wanaque.

REMNANTS OF HURRICANE IDA
Hurricane FEMA DR-4614
REMNANTS OF HURRICANE IDA
Hurricane FEMA DR-3573
HURRICANE SANDY
Hurricane FEMA DR-4086

Where does Wayne Twp.-1614's water come from?

Wayne Twp.-1614's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 1 water system serving approximately 55,000 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Whippany River Near Pine Brook (river), Passaic River At Pine Brook (river), Passaic R At Horse Neck Bridge Near Pine Bk (river), Pequannock River At Riverdale (river), West Brook Near Wanaque (river).

What Wayne Twp.-1614 residents can do

Install a water filter

Recommended: Reverse osmosis system. This addresses the specific contaminants found in Wayne Twp.-1614's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Wayne Twp.-1614's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.0 ppb
EPA Action Level: 15 ppb · 0% of limit
Safe Level
PFOA
PFAS / Forever Chemical
Over MCL
0.0049 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Exceeds MCL
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
25.5 µg/L
EPA MCL: 60 µg/L · 43% of limit
Within LimitUCMR 4 DataHAA6Br: 4.2 µg/LHAA9: 29.7 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.04 µg/L
CA MCL (no federal MCL): 10 µg/L · 0% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
64.7 µg/L
EPA Health Ref Level: 1,500 µg/L · 4% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
1.0 µg/L
EPA Secondary MCL: 50 µg/L · 2% of limit
DetectedUCMR 4 Data
Chlorate
Disinfection Byproduct
Elevated
128.0 µg/L
EPA Lifetime HA: 210 µg/L · 61% of limit
DetectedUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
1
Exceed EPA MCL
1.23
Hazard Index
PFOA max: 0.0049 µg/L
Compliance Record

Violation summary

22
Total violations
1
Health-based
8
Active / unresolved
Jul 2021
Most recent violation
Compliance Record

Violations & advisories

22 Total
8 Active
1 Health-based
14 Resolved
Violations by category
Lead and Copper Rule
6
Inorganic Chemicals
6
Consumer Confidence Rule
3
Stage 2 Disinfectants and Disinfection Byproducts Rule
2
Revised Total Coliform Rule
1
Jul 2021 Active
Consumer Confidence Rule
Other Violation 0
Jul 2020 Active
Consumer Confidence Rule
Other Violation 0
Oct 2019 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Dec 2018 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Apr 2018 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
May 2016 Active
Revised Total Coliform Rule
Reporting
Reporting 0
Jul 2014 Active
Consumer Confidence Rule
Other Violation 0
Active
Compliance Violation
Monitoring 0
Jan 2018 Resolved
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2018
Dec 2016 Resolved
TTHM
Monitoring & Reporting
Monitoring & Reporting Resolved Feb 2017
Dec 2016 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
Monitoring & Reporting Resolved Feb 2017
Jul 2016 Resolved
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2016
May 2014 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved May 2014
Jan 2011 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Jan 2011
Jan 1995 Resolved
Lead and Copper Rule
Treatment Technique
Health-Based Health Resolved May 1998
Jun 1979 Resolved
Arsenic
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1982
Jun 1979 Resolved
Cadmium
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1982
Jun 1979 Resolved
Barium
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1982
Jun 1979 Resolved
Chromium
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1982
Jun 1979 Resolved
Selenium
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1982
Showing 20 of 22 violations
Environmental Risk

Drought conditions

D1 — moderate drought

Passaic County is currently in D1 (moderate drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

16.0%
Months in D2+ (last 30y)
7
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

10
Declared disasters
Sep 2021
Most recent
Hurricane
Most common type

Passaic County has experienced 10 federally declared disasters since 1984. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Sep 2021
REMNANTS OF HURRICANE IDA
Hurricane FEMA #4614
Sep 2021
REMNANTS OF HURRICANE IDA
Hurricane FEMA #3573
Oct 2012
HURRICANE SANDY
Hurricane FEMA #4086
Oct 2012
HURRICANE SANDY
Hurricane FEMA #3354
Aug 2011
HURRICANE IRENE
Hurricane FEMA #4021
Aug 2011
HURRICANE IRENE
Hurricane FEMA #3332

Recommended water filters

Based on contaminants detected in Wayne Twp.-1614's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
PFAS compounds exceed EPA maximum contaminant levels

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA 0.005 0.004 µg/L PFAS Over MCL
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 18.0 ppb from 1992 (18.0 ppb) to 2025 (0.0 ppb).
Contaminant Rankings

See how Wayne Twp.-1614 compares by contaminant

Explore where Wayne Twp.-1614 ranks among all New Jersey cities for specific contaminants.

Infrastructure

Water source & infrastructure

Primary Source
Purchased Surface Water
Operator
Local Government
Population Served
55,000
Water Systems
1
Water Source

Where Wayne Twp.-1614's water comes from

Purchased Surface Water

Wayne Twp.-1614's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 55,000 people through 1 water system.

Local Hydrology

Water bodies near Wayne Twp.-1614

Wayne Twp.-1614 is located near 5 notable water bodies. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Whippany River Near Pine Brook
river
Passaic River At Pine Brook
river
Passaic R At Horse Neck Bridge Near Pine Bk
river
Pequannock River At Riverdale
river
West Brook Near Wanaque
river
Infrastructure

Water systems serving Wayne Twp.-1614

System Name PWSID Population Source
TOWNSHIP OF WAYNE NJ1614001 55,000 SWP
Regional Comparison

How Wayne Twp.-1614 compares

Full New Jersey rankings →

Wayne Twp.-1614's score of 84.8/100 is above the average of 63/100 among major New Jersey cities. It outscores 10 of 10 nearby cities.

Wayne Twp.-1614 (this city)
84.8
New Jersey avg
63
City Profile

About Wayne Twp.-1614, NJ

Wikipedia →

Wayne is a township in Passaic County, in the U.S. state of New Jersey. Home to William Paterson University and located less than 20 miles (32 km) from Midtown Manhattan, the township is a bedroom suburb of New York City and regional commercial hub of North Jersey. As of the 2020 United States census, the township's population was 54,838, an increase of 121 (+0.2%) from the 2010 census count of 54,717, which in turn reflected an increase of 648 (+1.2%) from the 54,069 counted in the 2000 census.

Economic Profile
$147,740
Median Income
$565,007
Median Home Value
$2,038/mo
Median Rent
5.2%
Unemployment
Community
42.5
Median Age
881
People / sq mi
56.2%
College Educated
77.9%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Wayne Twp.-1614, NJ tap water safe to drink?

Wayne Twp.-1614's water quality earned a grade of B+ (84.8/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #54 out of 435 cities tested in New Jersey.

What contaminants are in Wayne Twp.-1614's water?

Lead was measured at 0.0 ppb (90th percentile). 1 PFAS compound was detected. 22 violations are on record.

How is Wayne Twp.-1614's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Wayne Twp.-1614?

PFAS compounds exceed EPA limits — a reverse osmosis or activated carbon filter is recommended.

Where does Wayne Twp.-1614's water come from?

Wayne Twp.-1614's water is sourced from Purchased surface water. The city has 1 water system serving approximately 55,000 residents.

What health violations has Wayne Twp.-1614's water system had?

Wayne Twp.-1614 has 1 health-based violation on record. The most recent violation was recorded in July 2021. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 8 violations remain unresolved.

How does Wayne Twp.-1614's water compare to other cities?

Wayne Twp.-1614 ranks #54 out of 435 cities in New Jersey (better than 88% of state cities) and #5636 out of 15744 cities nationally (64th percentile). The grade of B+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.