Is Gloucester City-0414, NJ Tap Water Safe to Drink?

Graded A- — but 1,4-Dioxane and Chlorate were detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

12K residents served 1 water system PWSID: NJ0414001
Overall Score
85.4 / 100
Violations
12 active
Last Updated
May 2026
Source
Groundwater
#50 of 435 in New Jersey Top 34% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
A-GRADE
Water Quality Grade
85.4/100
waterverge.com
A- 85.4/100

Gloucester City-0414, NJ — Water Quality Report

Gloucester City-0414's drinking water received a grade of A- (85.4 out of 100), indicating good water quality. The city's 1 water system serves approximately 12,460 residents using groundwater.

Lead levels were measured at 2.0 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 91 violations on record, including 2 health-based violations. 12 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Gloucester City-0414's water

Gloucester City-0414 ranks #50 out of 435 cities in New Jersey for water quality, placing it above average in the state.

Gloucester City-0414 relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 0.03 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

Quality Breakdown

Water quality score

See methodology →
85.4 out of 100 Grade A-
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
36.2/45
B
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 2.0 ppb (90th percentile).
Contaminants
16.2/20
B
1 PFAS compound detected.
Compliance
8/10
B
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Gloucester City-0414, NJ water safe to drink?

Concerns Identified

Gloucester City-0414's drinking water has significant quality concerns based on EPA testing data. With a grade of A- (85.4/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 12,460 residents using groundwater (wells).

12
Active Violations
2.0 ppb
Lead (90th %ile)
1 compound
PFAS Detected

Recent water quality updates for Gloucester City-0414

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Gloucester City-0414's water quality assessment. Grade: A- (85.4/100).

Violation
1 drinking water violation recorded

Contaminants: Chlorine.

Violation
1 drinking water violation recorded

Contaminants: Lead and Copper Rule.

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Gloucester City-0414's water supply.

Lead Within Limits
Detected: 2.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (1 compound) Elevated
Detected: Highest: lithium at 9.5000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Gloucester City-0414's water system has 91 total violations on record, including 2 health-based violations. 12 remain unresolved. 1 violation was issued in the last 5 years.

MROtherMCL
Most recent violations:
Oct 2021 Chlorine Resolved
Dec 2020 Lead and Copper Rule Open
Oct 2020 Consumer Confidence Rule Open
Jul 2020 Consumer Confidence Rule Open
Oct 2019 Consumer Confidence Rule Open

Where does Gloucester City-0414's water come from?

Gloucester City-0414's drinking water comes from groundwater (wells), supplied by 1 water system serving approximately 12,460 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate.

What Gloucester City-0414 residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Gloucester City-0414's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
2.0 ppb
EPA Action Level: 15 ppb · 13% of limit
Safe Level
lithium
PFAS / Forever Chemical
Near MCL
9.5000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
2.3 µg/L
EPA MCL: 60 µg/L · 4% of limit
Within LimitUCMR 4 DataHAA6Br: 1.1 µg/LHAA9: 3.1 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.03 µg/L
CA MCL (no federal MCL): 10 µg/L · 0% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Elevated
1500.0 µg/L
EPA Health Ref Level: 1,500 µg/L · +0% over limit
DetectedUCMR 3 Data
1,4-Dioxane
Organic
Over HA
1.10 µg/L
EPA Health Advisory: 0.35 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
Manganese
Inorganic
Elevated
36.0 µg/L
EPA Secondary MCL: 50 µg/L · 72% of limit
DetectedUCMR 4 Data
Chlorate
Disinfection Byproduct
Over HA
453.0 µg/L
EPA Lifetime HA: 210 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
Lithium
Inorganic
Detected
9.5 µg/L
State screening level: 60 µg/L · 16% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

91
Total violations
2
Health-based
12
Active / unresolved
Oct 2021
Most recent violation
Compliance Record

Violations & advisories

91 Total
12 Active
2 Health-based
79 Resolved
2 SNC
Violations by category
Volatile Organic Chemicals
63
Consumer Confidence Rule
7
Stage 2 Disinfectants and Disinfection Byproducts Rule
6
Total Coliform Rule
5
Stage 1 Disinfectants and Disinfection Byproducts Rule
4
Dec 2020 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Oct 2020 Active
Consumer Confidence Rule
Other Violation 0
Jul 2020 Active
Consumer Confidence Rule
Other Violation 0
Oct 2019 Active
Consumer Confidence Rule
Other Violation 0
Jul 2019 Active
Consumer Confidence Rule
Other Violation 0
Oct 2018 Active
Consumer Confidence Rule
Other Violation 0
Jul 2018 Active
Consumer Confidence Rule
Other Violation 0
Jan 2018 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Aug 2017 Active
Revised Total Coliform Rule
Other Violation 0
Jul 2016 Active
Consumer Confidence Rule
Other Violation 0
Oct 2014 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Oct 2021 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2021
Feb 2019 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
Monitoring & Reporting Resolved Apr 2019
Feb 2019 Resolved
TTHM
Monitoring & Reporting
Monitoring & Reporting Resolved Apr 2019
Oct 2018 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
SNC Monitoring & Reporting Resolved Dec 2018
Aug 2017 Resolved
TTHM
Monitoring & Reporting
Monitoring & Reporting Resolved Oct 2017
Aug 2017 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
Monitoring & Reporting Resolved Oct 2017
Feb 2016 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
SNC Monitoring & Reporting Resolved Apr 2016
Jul 2014 Resolved
cis-1,2-Dichloroethylene
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2014
Showing 20 of 91 violations
Environmental Risk

Drought conditions

D2 — severe drought

Camden County is currently in D2 (severe drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

2
Weeks at D2+ (current streak)
7.7%
Months in D2+ (last 30y)
2
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Recommended water filters

Based on contaminants detected in Gloucester City-0414's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 2.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 9.500 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 18.8 ppb from 1992 (20.8 ppb) to 2023 (2.0 ppb).
Contaminant Rankings

See how Gloucester City-0414 compares by contaminant

Explore where Gloucester City-0414 ranks among all New Jersey cities for specific contaminants.

Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Local Government
Population Served
12,460
Water Systems
1
Water Source

Where Gloucester City-0414's water comes from

Groundwater

Gloucester City-0414's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 12,460 people through 1 water system.

Infrastructure

Water systems serving Gloucester City-0414

System Name PWSID Population Source
GLOUCESTER CITY W DEPT NJ0414001 12,460 GW
Regional Comparison

How Gloucester City-0414 compares

Full New Jersey rankings →

Gloucester City-0414's score of 85.4/100 is above the average of 63/100 among major New Jersey cities. It outscores 10 of 10 nearby cities.

Gloucester City-0414 (this city)
85.4
New Jersey avg
63
City Profile

About Gloucester City-0414, NJ

Economic Profile
$95,084
Median Income
$236,707
Median Home Value
$1,422/mo
Median Rent
6.3%
Unemployment
Community
39.9
Median Age
1,107
People / sq mi
33%
College Educated
72.9%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Gloucester City-0414, NJ tap water safe to drink?

Gloucester City-0414's water quality earned a grade of A- (85.4/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #50 out of 435 cities tested in New Jersey.

What contaminants are in Gloucester City-0414's water?

Lead was measured at 2.0 ppb (90th percentile). 1 PFAS compound was detected. 91 violations are on record.

How is Gloucester City-0414's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Gloucester City-0414?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Gloucester City-0414's water come from?

Gloucester City-0414's water is sourced from Groundwater. The city has 1 water system serving approximately 12,460 residents.

What health violations has Gloucester City-0414's water system had?

Gloucester City-0414 has 2 health-based violations on record. The most recent violation was recorded in October 2021. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 12 violations remain unresolved.

Is Gloucester City-0414's groundwater at risk of contamination?

Gloucester City-0414 uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 91 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Gloucester City-0414's water compare to other cities?

Gloucester City-0414 ranks #50 out of 435 cities in New Jersey (better than 89% of state cities) and #5332 out of 15744 cities nationally (66th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.