WaterVerge

Is Tye, TX Tap Water Safe to Drink?

Graded C+, with 16 unresolved violations on record. See what was cited — and what it means for your tap. What to do next ↓

1K residents served 1 water system PWSID: TX2210011
Overall Score
67.2 / 100
Violations
16 active
Last Updated
May 2026
Source
Purchased surface water
#620 of 1067 in Texas Top 72% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
C+GRADE
Water Quality Grade
67.2/100
waterverge.com
C+ 67.2/100

Tye, TX — Water Quality Report

Tye's drinking water received a grade of C+ (67.2 out of 100), indicating fair water quality. The city's 1 water system serves approximately 1,176 residents using purchased surface water.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 10 PFAS compounds, with levels exceeding EPA maximum contaminant levels in the water supply.

The system has 30 violations on record, including 2 health-based violations. 16 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Tye's water

Tye ranks #620 out of 1067 cities in Texas for water quality, placing it below average in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

Of particular concern: PFAS "forever chemical" levels exceed the 2024 EPA maximum contaminant levels. These synthetic compounds don't break down naturally and require specialized filtration such as reverse osmosis or granular activated carbon.

As a small community water system, Tye may have fewer resources for advanced treatment technologies and infrastructure upgrades compared to larger utilities.

The system has seen 11 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
67.2 out of 100 Grade C+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
27/45
C
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.0 ppb (90th percentile).
Contaminants
13.2/20
C
10 PFAS compounds detected.
Compliance
3/10
F
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Purchased surface water.
Water Safety

Is Tye, TX water safe to drink?

Concerns Identified

Tye's drinking water has significant quality concerns based on EPA testing data. With a grade of C+ (67.2/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 1,176 residents using surface water (rivers, lakes, or reservoirs).

16
Active Violations
0.0 ppb
Lead (90th %ile)
10 compounds
PFAS Detected
1 event
Disaster History

Recent water quality updates for Tye

A timeline of significant water quality events, violations, and data updates.

PFAS
10 PFAS "forever chemical" compounds detected

PFAS levels exceed EPA maximum contaminant levels. Reverse osmosis or activated carbon filtration recommended.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Tye's water quality assessment. Grade: C+ (67.2/100).

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Public Notice.

Violation
1 drinking water violation recorded

Contaminants: Chlorine.

Disaster
HURRICANE RITA

Federal disaster declaration (FEMA DR-1606). Hurricane event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Tye's water supply.

Lead Within Limits
Detected: 0.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (10 compounds) Elevated
Detected: Highest: lithium at 13.5000 µg/L Limit: 0.004 µg/L (EPA MCL)

PFAS "forever chemicals" exceed EPA maximum contaminant levels. Reverse osmosis or granular activated carbon filtration strongly recommended.

PFAS "forever chemicals" detected

UCMR 5 testing found 10 PFAS compounds in Tye's water supply. PFAS are synthetic chemicals that persist indefinitely in the environment and the human body.

Compound Level EPA MCL Status
lithium 13.5000 µg/L 0.004 µg/L Within Limit
PFOS 0.0204 µg/L 0.004 µg/L Over MCL
PFHxS 0.0190 µg/L 0.004 µg/L Within Limit
PFHxA 0.0132 µg/L 0.004 µg/L Within Limit

Violation history

Tye's water system has 30 total violations on record, including 2 health-based violations. 16 remain unresolved. 11 violations were issued in the last 5 years.

OtherMRRPTTTMONMCL
Most recent violations:
Jul 2025 Consumer Confidence Rule Open
May 2025 Public Notice Open
Apr 2025 Chlorine Resolved
Dec 2024 Lead and Copper Rule Open
Oct 2024 LEAD AND COPPER RULE REVISIONS Open

Flood & environmental risk

Taylor County has experienced 1 federally declared disaster since 2005. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Clear Fk Brazos Rv At Hwy 83 Nr Hawley, Cat Claw Ck At Abilene, Elm Ck At Abilene, Kirby Lk At Abilene.

HURRICANE RITA
Hurricane FEMA DR-1606

Where does Tye's water come from?

Tye's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 1 water system serving approximately 1,176 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Clear Fk Brazos Rv At Hwy 83 Nr Hawley (river), Cat Claw Ck At Abilene (river), Elm Ck At Abilene (river), Kirby Lk At Abilene (lake).

What Tye residents can do

Install a water filter

Recommended: Reverse osmosis system. This addresses the specific contaminants found in Tye's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.0 ppb
EPA Action Level: 15 ppb · 0% of limit
Safe Level
lithium
PFAS / Forever Chemical
Near MCL
13.5000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
Lithium
Inorganic
Detected
13.5 µg/L
State screening level: 60 µg/L · 23% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
10
Detected
2
Exceed EPA MCL
6.28
Hazard Index
PFOS max: 0.0204 µg/L PFOA max: 0.0047 µg/L
Compliance Record

Violation summary

30
Total violations
2
Health-based
16
Active / unresolved
Jul 2025
Most recent violation
Compliance Record

Violations & advisories

30 Total
16 Active
2 Health-based
14 Resolved
Violations by category
Public Notice Rule and Revised PN Rule
7
Revised Total Coliform Rule
5
Total Coliform Rule
5
Stage 1 Disinfectants and Disinfection Byproducts Rule
4
Lead and Copper Rule
4
Jul 2025 Active
Consumer Confidence Rule
Other Violation 0
May 2025 Active
Public Notice
Other Violation 0
Dec 2024 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Treatment Technique
Health-Based Health 0
Dec 2021 Active
Public Notice
Other Violation 0
Jul 2021 Active
Consumer Confidence Rule
Other Violation 0
Oct 2020 Active
Public Notice
Other Violation 0
Oct 2020 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Dec 2019 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Oct 2015 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Feb 2014 Active
Public Notice
Other Violation 0
Feb 2014 Active
Public Notice
Other Violation 0
Jul 2008 Active
Public Notice
Other Violation 0
Dec 2005 Active
Public Notice
Other Violation 0
Active
Compliance Violation
Monitoring 0
Apr 2025 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2025
Jun 2023 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Jun 2023
May 2023 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved May 2023
Nov 2022 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Nov 2022
Showing 20 of 30 violations
Industrial pollution

Top industrial polluters within 10 miles of Tye

Industrial polluters nearby

Reported releases to surface water by facilities near Tye, ranked by pounds discharged annually.

Total reported releases to surface water: 42 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
BROADWIND TOWERS INC
Fabricated Metals · BROADWIND ENERGY INC
ABILENE, TX79603
Manganese423.4 mi
WESTERN MARKETING INC.
Petroleum Bulk Terminals · RELADYNE LLC
TYE, TX79563
1.1 mi
CARGILL FEED & NUTRITION ABILENE
Food · CARGILL INC
ABILENE, TX79602
8.2 mi
INGRAM CONCRETE - ABILENE 4
Nonmetallic Mineral Product · SMYRNA READY MIX LLC
ABILENE, TX79602
9.4 mi
14122 ABILENE 1
Nonmetallic Mineral Product · SMYRNA READY MIX LLC
ABILENE, TX79603
5.3 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Environmental Risk

Drought conditions

D1 — moderate drought

Taylor County is currently in D1 (moderate drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

14.2%
Months in D2+ (last 30y)
2
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

1
Declared disasters
Sep 2005
Most recent
Hurricane
Most common type

Taylor County has experienced 1 federally declared disaster since 2005. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Sep 2005
HURRICANE RITA
Hurricane FEMA #1606

Recommended water filters

Based on contaminants detected in Tye's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
PFAS compounds exceed EPA maximum contaminant levels

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS 0.007 HI µg/L PFAS Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 13.500 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.005 HI µg/L PFAS Detected
PFBS 0.005 HI µg/L PFAS Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA 0.007 HI µg/L PFAS Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA 0.013 HI µg/L PFAS Detected
PFHxS 0.019 HI µg/L PFAS Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA 0.005 0.004 µg/L PFAS Over MCL
PFOS 0.020 0.004 µg/L PFAS Over MCL
PFPeA 0.012 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 4.3 ppb from 1993 (4.3 ppb) to 2025 (0.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Purchased Surface Water
Operator
Local Government
Population Served
1,176
Water Systems
1
Water Source

Where Tye's water comes from

Purchased Surface Water

Tye's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 1,176 people through 1 water system.

Local Hydrology

Water bodies near Tye

Tye is located near 4 notable water bodies. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Clear Fk Brazos Rv At Hwy 83 Nr Hawley
river
Cat Claw Ck At Abilene
river
Elm Ck At Abilene
river
Kirby Lk At Abilene
lake
Infrastructure

Water systems serving Tye

System Name PWSID Population Source
CITY OF TYE TX2210011 1,176 SWP
Regional Comparison

How Tye compares

Full Texas rankings →

Tye's score of 67.2/100 is above the average of 46/100 among major Texas cities. It outscores 8 of 10 nearby cities.

Tye (this city)
67.2
Houston
27.8
Austin
31.2
Dallas
36.2
Fort Worth
34.5
Texas avg
46
City Profile

About Tye, TX

Wikipedia →

Tye is a city in Taylor County, Texas, United States. Its population was 1,176 at the 2020 census. It is part of the Abilene, Texas metropolitan statistical area.

Economic Profile
$50,139
Median Income
$60,375
Median Home Value
$971/mo
Median Rent
0%
Unemployment
Community
49.2
Median Age
88
People / sq mi
6.5%
College Educated
86.1%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Tye, TX tap water safe to drink?

Tye's water quality earned a grade of C+ (67.2/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #620 out of 1067 cities tested in Texas.

What contaminants are in Tye's water?

Lead was measured at 0.0 ppb (90th percentile). 10 PFAS compounds were detected. 30 violations are on record.

How is Tye's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Tye?

PFAS compounds exceed EPA limits — a reverse osmosis or activated carbon filter is recommended.

Where does Tye's water come from?

Tye's water is sourced from Purchased surface water. The city has 1 water system serving approximately 1,176 residents.

What health violations has Tye's water system had?

Tye has 2 health-based violations on record. The most recent violation was recorded in July 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 16 violations remain unresolved.

Why does Tye have so many PFAS compounds in its water?

10 different PFAS "forever chemical" compounds were detected in Tye's water supply during UCMR 5 testing. PFAS contamination often originates from proximity to military installations (AFFF firefighting foam), airports, industrial manufacturing sites, or wastewater treatment facilities. Some levels exceed the 2024 EPA maximum contaminant levels — a reverse osmosis or NSF-certified activated carbon filter is strongly recommended.

How does Tye's water compare to other cities?

Tye ranks #620 out of 1067 cities in Texas (better than 42% of state cities) and #11267 out of 15744 cities nationally (28th percentile). The grade of C+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Does Tye's small water system affect quality?

Tye's system serves approximately 1,176 residents. Small community water systems (under 3,300 people) may have fewer financial resources for infrastructure upgrades and advanced treatment technologies. However, they are held to the same EPA drinking water standards as larger systems. This system has 30 violations on record.