WaterVerge

Is Menard, TX Tap Water Safe to Drink?

Graded A-, with 3 unresolved violations on record. See what was cited — and what it means for your tap. What to do next ↓

1K residents served 1 water system PWSID: TX1640001
Overall Score
86.5 / 100
Violations
3 active
Last Updated
May 2026
Source
Ground water under influence
#152 of 1067 in Texas Top 30% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
A-GRADE
Water Quality Grade
86.5/100
waterverge.com
A- 86.5/100

Menard, TX — Water Quality Report

Menard's drinking water received a grade of A- (86.5 out of 100), indicating good water quality. The city's 1 water system serves approximately 1,471 residents using ground water under influence.

Lead levels were measured at 1.1 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 5 violations on record, including 1 health-based violation. 3 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Menard's water

Menard ranks #152 out of 1067 cities in Texas for water quality, placing it above average in the state.

Menard relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 0.05 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

As a small community water system, Menard may have fewer resources for advanced treatment technologies and infrastructure upgrades compared to larger utilities.

Quality Breakdown

Water quality score

See methodology →
86.5 out of 100 Grade A-
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
41.7/45
A
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 1.1 ppb (90th percentile).
Contaminants
18.2/20
A
1 PFAS compound detected.
Compliance
3/10
F
Monitoring and reporting compliance with EPA regulations.
Source Risk
3.5/5
C
Water source: Ground water under influence.
Water Safety

Is Menard, TX water safe to drink?

Concerns Identified

Menard's drinking water has significant quality concerns based on EPA testing data. With a grade of A- (86.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 1,471 residents using groundwater (wells).

3
Active Violations
1.1 ppb
Lead (90th %ile)
1 compound
PFAS Detected
3 events
Disaster History

Recent water quality updates for Menard

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Menard's water quality assessment. Grade: A- (86.5/100).

Disaster
SEVERE STORMS, STRAIGHT-LINE WINDS, AND FLOODING

Federal disaster declaration (FEMA DR-4879). Flood event — may have impacted local water infrastructure.

Violation
1 drinking water violation recorded

Contaminants: Lead and Copper Rule.

Violation
1 drinking water violation recorded

1 health-based. Contaminants: Revised Total Coliform Rule.

Disaster
SEVERE STORMS AND FLOODING

Federal disaster declaration (FEMA DR-4416). Flood event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Menard's water supply.

Lead Within Limits
Detected: 1.1 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (1 compound) Elevated
Detected: Highest: lithium at 15.1000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Menard's water system has 5 total violations on record, including 1 health-based violation. 3 remain unresolved. 2 violations were issued in the last 5 years.

MRMCL
Most recent violations:
Dec 2023 Lead and Copper Rule Open
Jun 2021 Revised Total Coliform Rule Resolved
Apr 2018 Interim Enhanced Surface Water Treatment Rule Resolved
Dec 2017 Lead and Copper Rule Open

Flood & environmental risk

Menard County has experienced 3 federally declared disasters since 2005. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Noyes Canal At Diversion Pt Nr. Menard, San Saba Rv At Menard.

SEVERE STORMS, STRAIGHT-LINE WINDS, AND FLOODING
Flood FEMA DR-4879
SEVERE STORMS AND FLOODING
Flood FEMA DR-4416
HURRICANE RITA
Hurricane FEMA DR-1606

Where does Menard's water come from?

Menard's drinking water comes from groundwater (wells), supplied by 1 water system serving approximately 1,471 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Noyes Canal At Diversion Pt Nr. Menard (stream), San Saba Rv At Menard (river).

What Menard residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Menard's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Menard's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
1.1 ppb
EPA Action Level: 15 ppb · 8% of limit
Safe Level
lithium
PFAS / Forever Chemical
Near MCL
15.1000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.05 µg/L
CA MCL (no federal MCL): 10 µg/L · 0% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
695.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 46% of limit
DetectedUCMR 3 Data
Vanadium
Inorganic
Detected
6.60 µg/L
EPA Short-term HA: 21 µg/L · 31% of limit
DetectedUCMR 3 Data
Chlorate
Disinfection Byproduct
Detected
43.0 µg/L
EPA Lifetime HA: 210 µg/L · 20% of limit
DetectedUCMR 3 Data
Molybdenum
Inorganic
Detected
2.20 µg/L
EPA Lifetime HA: 40 µg/L · 6% of limit
DetectedUCMR 3 Data
Lithium
Inorganic
Detected
15.1 µg/L
State screening level: 60 µg/L · 25% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

5
Total violations
1
Health-based
3
Active / unresolved
Dec 2023
Most recent violation
Compliance Record

Violations & advisories

5 Total
3 Active
1 Health-based
2 Resolved
Violations by category
Lead and Copper Rule
2
Revised Total Coliform Rule
1
Interim and Long Term 1 Enhanced Surface Water Treatment Rule
1
Dec 2023 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Dec 2017 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Jun 2021 Resolved
Revised Total Coliform Rule
Max Contaminant Level
Health-Based Health Resolved Jun 2021
Apr 2018 Resolved
Interim Enhanced Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Apr 2018
Environmental Risk

Flood & disaster history

3
Declared disasters
Jul 2025
Most recent
Flood
Most common type

Menard County has experienced 3 federally declared disasters since 2005. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Jul 2025
SEVERE STORMS, STRAIGHT-LINE WINDS, AND FLOODING
Flood FEMA #4879
Feb 2019
SEVERE STORMS AND FLOODING
Flood FEMA #4416
Sep 2005
HURRICANE RITA
Hurricane FEMA #1606

Recommended water filters

Based on contaminants detected in Menard's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.1 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 15.100 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 2.6 ppb from 1993 (3.8 ppb) to 2023 (1.1 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Ground Water Under Influence
Operator
Local Government
Population Served
1,471
Water Systems
1
Water Source

Where Menard's water comes from

Ground Water Under Influence

Menard's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 1,471 people through 1 water system.

Local Hydrology

Water bodies near Menard

Menard is located near 2 notable water bodies. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Noyes Canal At Diversion Pt Nr. Menard
stream
San Saba Rv At Menard
river
Infrastructure

Water systems serving Menard

System Name PWSID Population Source
CITY OF MENARD TX1640001 1,471 GU
Regional Comparison

How Menard compares

Full Texas rankings →

Menard's score of 86.5/100 is above the average of 46/100 among major Texas cities. It outscores 9 of 10 nearby cities.

Menard (this city)
86.5
Houston
27.8
Austin
31.2
Dallas
36.2
Fort Worth
34.5
Texas avg
46
City Profile

About Menard, TX

Economic Profile
$37,601
Median Income
$68,989
Median Home Value
$714/mo
Median Rent
8%
Unemployment
Community
59
Median Age
254
People / sq mi
18%
College Educated
72.5%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Menard, TX tap water safe to drink?

Menard's water quality earned a grade of A- (86.5/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #152 out of 1067 cities tested in Texas.

What contaminants are in Menard's water?

Lead was measured at 1.1 ppb (90th percentile). 1 PFAS compound was detected. 5 violations are on record.

How is Menard's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Menard?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Menard's water come from?

Menard's water is sourced from Ground water under influence. The city has 1 water system serving approximately 1,471 residents.

What health violations has Menard's water system had?

Menard has 1 health-based violation on record. The most recent violation was recorded in December 2023. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 3 violations remain unresolved.

Is Menard's groundwater at risk of contamination?

Menard uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 5 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Menard's water compare to other cities?

Menard ranks #152 out of 1067 cities in Texas (better than 86% of state cities) and #4677 out of 15744 cities nationally (70th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Does Menard's small water system affect quality?

Menard's system serves approximately 1,471 residents. Small community water systems (under 3,300 people) may have fewer financial resources for infrastructure upgrades and advanced treatment technologies. However, they are held to the same EPA drinking water standards as larger systems. This system has 5 violations on record.