WaterVerge

Is Dickinson, TX Tap Water Safe to Drink?

Graded F — but Copper and Chlorate were detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

30K residents served 2 water systems PWSID: TX0840001
Overall Score
44.9 / 100
Violations
32 active
Last Updated
May 2026
Source
Purchased surface water
#900 of 1067 in Texas Top 91% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
FGRADE
Water Quality Grade
44.9/100
waterverge.com
F 44.9/100

Dickinson, TX — Water Quality Report

Dickinson's drinking water received a grade of F (44.9 out of 100), indicating failing water quality. The city's 2 water systems serve approximately 30,477 residents using purchased surface water.

Lead levels were measured at 0.6 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 5 PFAS compounds in the water supply.

The system has 45 violations on record, including 8 health-based violations. 32 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Dickinson's water

Dickinson ranks #900 out of 1067 cities in Texas for water quality, placing it among the lowest-rated in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 0.08 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

The system has seen 18 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
44.9 out of 100 Grade F
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
10.6/45
F
Historical violation record including health-based and monitoring violations.
Lead & Copper
16/20
B
Lead at 0.6 ppb (90th percentile).
Contaminants
14.3/20
C
5 PFAS compounds detected.
Compliance
0/10
F
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Purchased surface water.
Water Safety

Is Dickinson, TX water safe to drink?

Concerns Identified

Dickinson's drinking water has significant quality concerns based on EPA testing data. With a grade of F (44.9/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 2 water systems serve approximately 30,477 residents using surface water (rivers, lakes, or reservoirs).

32
Active Violations
0.6 ppb
Lead (90th %ile)
5 compounds
PFAS Detected
9 events
Disaster History

Recent water quality updates for Dickinson

A timeline of significant water quality events, violations, and data updates.

PFAS
5 PFAS "forever chemical" compounds detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Dickinson's water quality assessment. Grade: F (44.9/100).

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Public Notice.

Violation
1 drinking water violation recorded

1 health-based. Contaminants: Revised Total Coliform Rule.

Disaster
HURRICANE BERYL

Federal disaster declaration (FEMA DR-4798). Hurricane event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Dickinson's water supply.

Lead Within Limits
Detected: 0.6 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Copper Exceeds Limit
Detected: 2.35 mg/L Limit: 1.3 mg/L (EPA Action Level)

Exceeds EPA action level. Copper can leach from household plumbing — flush taps for 30 seconds before drinking.

PFAS (5 compounds) Elevated
Detected: Highest: lithium at 17.4000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

PFAS "forever chemicals" detected

UCMR 5 testing found 5 PFAS compounds in Dickinson's water supply. PFAS are synthetic chemicals that persist indefinitely in the environment and the human body.

Compound Level EPA MCL Status
lithium 17.4000 µg/L 0.004 µg/L Within Limit
PFPeA 0.1570 µg/L 0.004 µg/L Within Limit
PFBA 0.0121 µg/L 0.004 µg/L Within Limit
PFHxA 0.0054 µg/L 0.004 µg/L Within Limit

Violation history

Dickinson's water system has 45 total violations on record, including 8 health-based violations. 32 remain unresolved. 18 violations were issued in the last 5 years.

OtherTTMONMRRPTMCL
Most recent violations:
Jul 2025 Consumer Confidence Rule Open
May 2025 Public Notice Open
Feb 2025 Revised Total Coliform Rule Open
Jan 2025 Revised Total Coliform Rule Resolved
Dec 2024 Lead and Copper Rule Open

Flood & environmental risk

Galveston County has experienced 9 federally declared disasters since 2007. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Clear Ck Nr Friendswood, Dickinson Bayou At Fm 517 Nr Alvin, Highland Bayou At Fm 646 Nr Santa Fe.

HURRICANE BERYL
Hurricane FEMA DR-4798
HURRICANE LAURA
Hurricane FEMA DR-4572
TROPICAL STORMS MARCO AND LAURA
Hurricane FEMA DR-3540

Where does Dickinson's water come from?

Dickinson's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 2 water systems serving approximately 30,477 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Clear Ck Nr Friendswood (river), Dickinson Bayou At Fm 517 Nr Alvin (river), Highland Bayou At Fm 646 Nr Santa Fe (river).

What Dickinson residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Dickinson's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Dickinson's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.6 ppb
EPA Action Level: 15 ppb · 4% of limit
Safe Level
Copper (90th percentile)
Inorganic
Over Limit
2.35 mg/L
EPA Action Level: 1.3 mg/L · +20% over limit
Exceeds Limit
lithium
PFAS / Forever Chemical
Near MCL
17.4000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
12.7 µg/L
EPA MCL: 60 µg/L · 21% of limit
Within LimitUCMR 4 DataHAA6Br: 24.2 µg/LHAA9: 30.7 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.08 µg/L
CA MCL (no federal MCL): 10 µg/L · 1% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
436.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 29% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
0.9 µg/L
EPA Secondary MCL: 50 µg/L · 2% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Detected
1.98 µg/L
EPA Short-term HA: 21 µg/L · 9% of limit
DetectedUCMR 3 Data
Chlorate
Disinfection Byproduct
Over HA
219.0 µg/L
EPA Lifetime HA: 210 µg/L · +4% over limit
Over Health AdvisoryUCMR 3 Data
Molybdenum
Inorganic
Detected
2.19 µg/L
EPA Lifetime HA: 40 µg/L · 5% of limit
DetectedUCMR 3 Data
Lithium
Inorganic
Detected
17.4 µg/L
State screening level: 60 µg/L · 29% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
5
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

45
Total violations
8
Health-based
32
Active / unresolved
Jul 2025
Most recent violation
Compliance Record

Violations & advisories

45 Total
32 Active
8 Health-based
13 Resolved
Violations by category
Lead and Copper Rule
10
Public Notice Rule and Revised PN Rule
9
Consumer Confidence Rule
6
Revised Total Coliform Rule
4
Ground Water Rule
4
Jul 2025 Active
Consumer Confidence Rule
Other Violation 0
May 2025 Active
Public Notice
Other Violation 0
Feb 2025 Active
Revised Total Coliform Rule
Treatment Technique
Health-Based Health 0
Dec 2024 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Nov 2024 Active
E. COLI
Monitoring & Reporting
Monitoring & Reporting 0
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Treatment Technique
Health-Based Health 0
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2024 Active
Consumer Confidence Rule
Other Violation 0
Jul 2023 Active
Consumer Confidence Rule
Other Violation 0
Jan 2023 Active
Public Notice
Other Violation 0
Oct 2021 Active
Public Notice
Other Violation 0
Jul 2021 Active
Consumer Confidence Rule
Other Violation 0
Jun 2021 Active
Public Notice
Other Violation 0
Apr 2021 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Mar 2021 Active
Public Notice
Other Violation 0
Sep 2020 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jul 2020 Active
Consumer Confidence Rule
Other Violation 0
Jun 2020 Active
Public Notice
Other Violation 0
Jun 2020 Active
Public Notice
Other Violation 0
Apr 2020 Active
Lead and Copper Rule
Treatment Technique
Health-Based Health 0
Showing 20 of 45 violations
Industrial pollution

Top industrial polluters within 10 miles of Dickinson

Industrial polluters nearby

Reported releases to surface water by facilities near Dickinson, ranked by pounds discharged annually.

Total reported releases to surface water: 267,371 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
BLANCHARD REFINING CO LLC
Petroleum · MARATHON PETROLEUM CORP
TEXAS CITY, TX77590
Nitrate compounds (water dissociable; reportable only when in aqueous solution)267,3719.2 mi
CUSTOM CHEMICAL SERVICES
Chemical Wholesalers · NA
HITCHCOCK, TX77563
Xylene (mixed isomers)18.5 mi
CLEAN HARBORS SAN LEON INC
Hazardous Waste · CLEAN HARBORS INC
SAN LEON, TX77539
5.6 mi
AIR PRODUCTS INDUSTRIAL GASES LLC
Chemicals · AIR PRODUCTS & CHEMICALS INC
TEXAS CITY, TX77590
10.0 mi
BP AMOCO CHEMICAL COMPANY
Chemicals · BP PRODUCTS NORTH AMERICA INC
TEXAS CITY, TX77590
10.0 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Site context

Superfund sites within 10 miles of Dickinson

Superfund sites nearby

Federally tracked hazardous-waste sites on the EPA National Priorities List. Proximity does not necessarily indicate tap-water contamination — the connection depends on hydrology and treatment.

Source: EPA Superfund National Priorities List

Environmental Risk

Drought conditions

D2 — severe drought

Galveston County is currently in D2 (severe drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

14
Weeks at D2+ (current streak)
12.2%
Months in D2+ (last 30y)
14
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

9
Declared disasters
Jul 2024
Most recent
Hurricane
Most common type

Galveston County has experienced 9 federally declared disasters since 2007. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Jul 2024
HURRICANE BERYL
Hurricane FEMA #4798
Dec 2020
HURRICANE LAURA
Hurricane FEMA #4572
Aug 2020
TROPICAL STORMS MARCO AND LAURA
Hurricane FEMA #3540
Jul 2020
HURRICANE HANNA
Hurricane FEMA #3530
Aug 2017
HURRICANE HARVEY
Hurricane FEMA #4332
Sep 2008
HURRICANE IKE
Hurricane FEMA #1791

Recommended water filters

Based on contaminants detected in Dickinson's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
5 PFAS compounds detected
🔧
For Copper
Reverse Osmosis or KDF Filter
Copper exceeds the EPA action level of 1.3 mg/L

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.6 15 ppb Inorganic Safe
Copper (90th percentile) 2.35 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 17.400 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.012 HI µg/L PFAS Detected
PFBS 0.004 HI µg/L PFAS Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA 0.005 HI µg/L PFAS Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA 0.157 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 3.0 ppb from 1992 (3.6 ppb) to 2024 (0.6 ppb).

Copper level (90th percentile)

Latest reading: 2.350 mg/L (2019)

EPA action level: 1.3 mg/L

Infrastructure

Water source & infrastructure

Primary Source
Purchased Surface Water
Operator
Local Government
Population Served
30,477
Water Systems
2
Source breakdown
Purchased Surface Water
1
Groundwater
1
Water Source

Where Dickinson's water comes from

Purchased Surface Water

Dickinson's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 30,477 people through 2 water systems.

Local Hydrology

Water bodies near Dickinson

Dickinson is located near 3 notable water bodies. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Clear Ck Nr Friendswood
river
Dickinson Bayou At Fm 517 Nr Alvin
river
Highland Bayou At Fm 646 Nr Santa Fe
river
Infrastructure

Water systems serving Dickinson

System Name PWSID Population Source
GALVESTON COUNTY WCID 1 TX0840001 30,399 SWP
WINDSONG PARK TX0840046 78 GW
Regional Comparison

How Dickinson compares

Full Texas rankings →

Dickinson's score of 44.9/100 is on par with the average of 46/100 among major Texas cities. It outscores 7 of 10 nearby cities.

Dickinson (this city)
44.9
Houston
27.8
Austin
31.2
Dallas
36.2
Fort Worth
34.5
Texas avg
46
City Profile

About Dickinson, TX

Wikipedia →

Dickinson is a city in Galveston County, Texas, United States, within Houston–The Woodlands–Sugar Land metropolitan area. Its population was 20,847 at the 2020 census.

Economic Profile
$81,739
Median Income
$213,905
Median Home Value
$1,163/mo
Median Rent
4.4%
Unemployment
Community
35.8
Median Age
832
People / sq mi
25.3%
College Educated
79%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Dickinson, TX tap water safe to drink?

Dickinson's water quality earned a grade of F (44.9/100). Significant issues have been found. A water filter is strongly recommended. The city ranks #900 out of 1067 cities tested in Texas.

What contaminants are in Dickinson's water?

Lead was measured at 0.6 ppb (90th percentile). 5 PFAS compounds were detected. 45 violations are on record.

How is Dickinson's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Dickinson?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Dickinson's water come from?

Dickinson's water is sourced from Purchased surface water. The city has 2 water systems serving approximately 30,477 residents.

What health violations has Dickinson's water system had?

Dickinson has 8 health-based violations on record. The most recent violation was recorded in July 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 32 violations remain unresolved.

Why does Dickinson have so many PFAS compounds in its water?

5 different PFAS "forever chemical" compounds were detected in Dickinson's water supply during UCMR 5 testing. PFAS contamination often originates from proximity to military installations (AFFF firefighting foam), airports, industrial manufacturing sites, or wastewater treatment facilities. While detected, current levels are within EPA limits. An activated carbon filter can further reduce exposure.

How does Dickinson's water compare to other cities?

Dickinson ranks #900 out of 1067 cities in Texas (better than 16% of state cities) and #14317 out of 15744 cities nationally (9th percentile). The grade of F reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.