Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is Bishop, TX Tap Water Safe to Drink?

Graded A-, with 3 unresolved violations on record. See what was cited — and what it means for your tap. What to do ↓

0 contaminants over a legal limit
1.6 ppb lead, 90th percentile · low
3 unresolved violations
3K people served by 1 water system

PWSID TX1780002 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
A 89.8 / 100

#42 of 1067Texas cities
How we grade →

01The verdict: is Bishop water safe?

Bishop's drinking water has significant quality concerns based on EPA testing data. With a grade of A- (89.8/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 3,186 residents using surface water (rivers, lakes, or reservoirs).

The concern

3 unresolved violations on record

EPA records show open compliance items for this system. Most are administrative, but unresolved items are worth watching.

See what was cited ↓
The good news

Lead is well under the limit

90th-percentile lead is 1.6 ppb — beneath the 15 ppb federal action level and under the 5 ppb watch threshold.

See the trend ↓
Keep watching

lithium is approaching its limit

Measured at 81.0000 µg/L — 120% of the 0.004 µg/L limit. Within the rules, but with less headroom than you'd want.

See the ledger ↓

Bishop's drinking water received a grade of A- (89.8 out of 100), indicating good water quality. The city's 1 water system serves approximately 3,186 residents using purchased surface water.

Lead levels were measured at 1.6 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 2 PFAS compounds in the water supply. The system has 16 violations on record, including 10 health-based violations. 3 remain unresolved.

Bishop ranks #42 out of 1067 cities in Texas for water quality, placing it one of the best in the state. The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection. PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter. As a small community water system, Bishop may have fewer resources for advanced treatment technologies and infrastructure upgrades compared to larger utilities.

How the 89.8/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
40.8 / 45A
Lead & CopperLead at 1.6 ppb (90th percentile).
20 / 20A
Contaminants2 PFAS compounds detected.
17 / 20B
ComplianceMonitoring and reporting compliance with EPA regulations.
8 / 10B
Source RiskWater source: Purchased surface water.
4 / 5B

02What's in Bishop's water

Every contaminant flagged in Bishop, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

3 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%
lithium PFAS / Forever Chemical
81.0000 µg/L 120% of limit
Lithium Inorganic
81.0 µg/L 120% of limit
32 contaminants tested under EPA SDWIS, LCR and UCMR programs · 4 detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.6 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 81.000 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.007 HI µg/L PFAS Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Bishop's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 16 violations on record, including 10 health-based violations. 3 remain unresolved.

8 of the last ten years were clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

2 monitoring & paperwork 2 still unresolved
PFAS2 PFAS "forever chemical" compounds detectedDetected at levels within current EPA limits. PFAS persist indefinitely in the environment.
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Bishop's water quality assessment. Grade: A- (89.8/100).
Violation1 drinking water violation recordedContaminants: Consumer Confidence Rule.Open
DisasterHURRICANE BERYLFederal disaster declaration (FEMA DR-4798). Hurricane event — may have impacted local water infrastructure.
DisasterTROPICAL STORMS MARCO AND LAURAFederal disaster declaration (FEMA DR-3540). Hurricane event — may have impacted local water infrastructure.
Violation1 drinking water violation recordedContaminants: Lead and Copper Rule.Open
Lead, 90th percentileppb · lower is better
05101520EPA action level · 15 ppb1993 — 7.3 ppb1994 — 4.6 ppb1995 — 5.9 ppb1998 — 2.6 ppb2001 — 3.7 ppb2007 — 2.9 ppb2010 — 1.6 ppb2013 — 4.2 ppb2016 — 3.5 ppb2019 — 1.5 ppb2022 — 1.4 ppb2025 — 1.6 ppb7.31.619931998201020192025

Down 5.7 ppb since 1993. Latest reading: 1.6 ppb (2025) — 11% of the action level. Sampled at higher-risk homes (90th percentile).

04Where Bishop's water comes from

Bishop's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Source

Purchased Surface Water

Rivers, lakes, or reservoirs — more exposed to runoff, agriculture, and seasonal swings than groundwater.

Treatment

Wholesale supplier

Multi-barrier treatment: coagulation, sedimentation, filtration, and disinfection to meet EPA standards.

Distribution

1 system

1 water system, operated under local government ownership.

Delivery

3,186 people

Residents served across Bishop's service area.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards. These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge. The system is operated by local government ownership and serves approximately 3,186 people through 1 water system.

System namePWSIDPopulationSource
CITY OF BISHOP TX1780002 3,186 Purchased Surface Water

Water bodies near Bishop

Tranquitas Ck At Kingsville · river Petronila Ck At Fm 665 Nr Driscoll · river

As a surface-water system, these water bodies may directly influence Bishop's drinking water supply.

05Pressure on Bishop's watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Industrial discharge

Present — monitored

5 facilities within 10 miles reported 517 lb released to surface water in the latest EPA Toxics Release Inventory. Proximity doesn't equal tap contamination — treatment and hydrology decide — but it's pressure on the watershed.

TICONA POLYMERS INC — formaldehyde 517 lb · 2.5 mi
OXEA BISHOP LLC 0 lb · 2.5 mi
BASF CORP 0 lb · 2.5 mi
+ 2 more facilities

Flood & storm history

Recurring — declared disasters

10 federal disaster declarations on record for Nueces County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

HURRICANE BERYL Jul 2024 · DR-4798
TROPICAL STORMS MARCO AND LAURA Aug 2020 · DR-3540
HURRICANE HANNA Jul 2020 · DR-3530

06How Bishop compares

Scores for nearby Texas cities on one line, with the average marked.

Bishop (this city)
89.8 · A-
Dallas
36.2 · F
Fort Worth
34.5 · F
San Antonio
33.1 · F
Austin
31.2 · F
Houston
27.8 · F

dashed line = Texas average (46/100)

Bishop scores 89.8/100above the Texas average of 46/100. It outscores 10 of 10 nearby cities. Full Texas rankings →

Nueces water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Bishop's water — not generic advice.

Because of pfas

Filter drinking & cooking water

Activated carbon or reverse osmosis filter. 2 PFAS compounds detected

Compare tested filters →
Know your report

Read your utility's annual report

Every utility must publish a yearly Consumer Confidence Report with its own testing results. It pairs well with the independent data on this page.

How to read a CCR →
Stay informed

Watch for Bishop alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Bishop, TX tap water safe to drink?

Bishop's water quality earned a grade of A- (89.8/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #42 out of 1067 cities tested in Texas.

What contaminants are in Bishop's water?

Lead was measured at 1.6 ppb (90th percentile). 2 PFAS compounds were detected. 16 violations are on record.

How is Bishop's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Bishop?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Bishop's water come from?

Bishop's water is sourced from Purchased surface water. The city has 1 water system serving approximately 3,186 residents.

What health violations has Bishop's water system had?

Bishop has 10 health-based violations on record. The most recent violation was recorded in July 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 3 violations remain unresolved.

How does Bishop's water compare to other cities?

Bishop ranks #42 out of 1067 cities in Texas (better than 96% of state cities) and #2566 out of 15382 cities nationally (83th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Does Bishop's small water system affect quality?

Bishop's system serves approximately 3,186 residents. Small community water systems (under 3,300 people) may have fewer financial resources for infrastructure upgrades and advanced treatment technologies. However, they are held to the same EPA drinking water standards as larger systems. This system has 16 violations on record.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Bishop, TX: Median household income $45,750 · median home value $97,073 · median age 43.6 · 85.8% homeowners · 16.2% college educated. Service area: 1 ZIP code across Nueces.
Show ZIP codes 78343
Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.