WaterVerge

Is Cordova, AK Tap Water Safe to Drink?

Graded B, with 4 unresolved violations on record. See what was cited — and what it means for your tap. What to do next ↓

3K residents served 1 water system PWSID: AK2293205
Overall Score
75.3 / 100
Violations
4 active
Last Updated
May 2026
Source
Surface water
#10 of 79 in Alaska Top 61% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
BGRADE
Water Quality Grade
75.3/100
waterverge.com
B 75.3/100

Cordova, AK — Water Quality Report

Cordova's drinking water received a grade of B (75.3 out of 100), indicating good water quality. The city's 1 water system serves approximately 2,700 residents using surface water.

Lead levels were measured at 6.0 ppb (90th percentile), which is within EPA limits but above recommended levels. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 268 violations on record, including 3 health-based violations. 4 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Cordova's water

Cordova ranks #10 out of 79 cities in Alaska for water quality, placing it above average in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

While lead levels are within EPA limits, they are above the recommended 5 ppb threshold that health organizations consider ideal. A point-of-use filter adds an extra layer of protection.

As a small community water system, Cordova may have fewer resources for advanced treatment technologies and infrastructure upgrades compared to larger utilities.

The system has seen 6 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
75.3 out of 100 Grade B
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
28.8/45
C
Historical violation record including health-based and monitoring violations.
Lead & Copper
18/20
A
Lead at 6.0 ppb (90th percentile).
Contaminants
14.5/20
C
1 PFAS compound detected.
Compliance
10/10
A
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Surface water.
Water Safety

Is Cordova, AK water safe to drink?

Concerns Identified

Cordova's drinking water has significant quality concerns based on EPA testing data. With a grade of B (75.3/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 2,700 residents using surface water (rivers, lakes, or reservoirs).

4
Active Violations
6.0 ppb
Lead (90th %ile)
1 compound
PFAS Detected

Recent water quality updates for Cordova

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Cordova's water quality assessment. Grade: B (75.3/100).

Violation
2 drinking water violations recorded

Contaminants: Interim Enhanced Surface Water Treatment Rule, Surface Water Treatment Rule.

Violation
3 drinking water violations recorded

Contaminants: Surface Water Treatment Rule, Chlorine, Revised Total Coliform Rule.

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Cordova's water supply.

Lead Elevated
Detected: 6.0 ppb Limit: 15 ppb (EPA Action Level)

Within EPA limits but above the American Academy of Pediatrics recommended level of 1 ppb. An NSF 53-certified filter provides additional protection.

PFAS (1 compound) Elevated
Detected: Highest: PFBA at 0.0371 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Cordova's water system has 268 total violations on record, including 3 health-based violations. 4 remain unresolved. 6 violations were issued in the last 5 years.

MRMONOtherTTMCL
Most recent violations:
Sep 2022 Interim Enhanced Surface Water Treatment Rule Resolved
Sep 2022 Surface Water Treatment Rule Resolved
Jul 2022 Surface Water Treatment Rule Resolved
Jul 2022 Chlorine Resolved
Jul 2022 Revised Total Coliform Rule Resolved

Where does Cordova's water come from?

Cordova's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 1 water system serving approximately 2,700 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment.

What Cordova residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Cordova's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Flush your taps

Run cold water for 30 seconds before drinking, especially in the morning. Lead and copper leach from household plumbing when water sits in pipes.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
6.0 ppb
EPA Action Level: 15 ppb · 40% of limit
Safe Level
PFBA
PFAS / Forever Chemical
Near MCL
0.0371 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

268
Total violations
3
Health-based
4
Active / unresolved
Sep 2022
Most recent violation
Compliance Record

Violations & advisories

268 Total
4 Active
3 Health-based
264 Resolved
1 SNC
Violations by category
Volatile Organic Chemicals
155
Inorganic Chemicals
46
Synthetic Organic Chemicals
18
Nitrate Rule
16
Surface Water Treatment Rule
7
Jul 2015 Active
Consumer Confidence Rule
Other Violation 0
Jul 2011 Active
Consumer Confidence Rule
Other Violation 0
Oct 2004 Active
Consumer Confidence Rule
Other Violation 0
Active
Compliance Violation
Monitoring 0
Sep 2022 Resolved
Interim Enhanced Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2022
Sep 2022 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2022
Jul 2022 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 2022
Jul 2022 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2022
Jul 2022 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Jul 2022
Dec 2021 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Dec 2021
Nov 2015 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Nov 2015
Jun 2015 Resolved
Interim Enhanced Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2015
Jun 2015 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2015
Jun 2015 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2015
Apr 2015 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2015
Mar 2015 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2015
Feb 2015 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
SNC Monitoring & Reporting Resolved Apr 2015
Jan 2015 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2015
Jul 2014 Resolved
Surface Water Treatment Rule
Treatment Technique
Health-Based Health Resolved Jul 2014
Nov 2008 Resolved
Total Coliform Rule
Other Violation Resolved Dec 2011
Showing 20 of 268 violations
Industrial pollution

Top industrial polluters within 10 miles of Cordova

Industrial polluters nearby

Reported releases to surface water by facilities near Cordova, ranked by pounds discharged annually.

FacilityTop chemicalTo surface water (lbs/yr)Distance
TRIDENT SEAFOODS - CORDOVA NORTH PLANT
Food · TTM TECHNOLOGIES INC
CORDOVA, AK99574
4.3 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Recommended water filters

Based on contaminants detected in Cordova's water supply, we recommend the following filter types.

🚰
For Lead
Reverse Osmosis or NSF 53-Certified Pitcher
Lead detected at 6.0 ppb
Read our guide →
🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 6.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.037 HI µg/L PFAS Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 6.3 ppb from 1996 (12.3 ppb) to 2024 (6.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Surface Water
Operator
Local Government
Population Served
2,700
Water Systems
1
Water Source

Where Cordova's water comes from

Surface Water

Cordova's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 2,700 people through 1 water system.

Infrastructure

Water systems serving Cordova

System Name PWSID Population Source
CORDOVA CITY WATER AK2293205 2,700 SW
Regional Comparison

How Cordova compares

Full Alaska rankings →

Cordova's score of 75.3/100 is above the average of 61/100 among major Alaska cities. It outscores 7 of 10 nearby cities.

Cordova (this city)
75.3
Anchorage
38.5
Fairbanks
38.4
Juneau
65.4
Wasilla
42.5
Alaska avg
61
City Profile

About Cordova, AK

Wikipedia →

Cordova is a port city in Chugach Census Area, Alaska, United States. It lies near the mouth of the Copper River, at the head of Orca Inlet on the east side of Prince William Sound. The population was 2,609 at the 2020 census, up from 2,239 in 2010.

Economic Profile
$79,526
Median Income
$343,406
Median Home Value
$1,375/mo
Median Rent
12.1%
Unemployment
Community
36.9
Median Age
16
People / sq mi
28.6%
College Educated
66.8%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Cordova, AK tap water safe to drink?

Cordova's water quality earned a grade of B (75.3/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #10 out of 79 cities tested in Alaska.

What contaminants are in Cordova's water?

Lead was measured at 6.0 ppb (90th percentile). 1 PFAS compound was detected. 268 violations are on record.

How is Cordova's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Cordova?

While lead levels are within EPA limits, a filter adds extra protection. PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Cordova's water come from?

Cordova's water is sourced from Surface water. The city has 1 water system serving approximately 2,700 residents.

What health violations has Cordova's water system had?

Cordova has 3 health-based violations on record. The most recent violation was recorded in September 2022. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 4 violations remain unresolved.

How does Cordova's water compare to other cities?

Cordova ranks #10 out of 79 cities in Alaska (better than 87% of state cities) and #9628 out of 15744 cities nationally (39th percentile). The grade of B reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Does Cordova's small water system affect quality?

Cordova's system serves approximately 2,700 residents. Small community water systems (under 3,300 people) may have fewer financial resources for infrastructure upgrades and advanced treatment technologies. However, they are held to the same EPA drinking water standards as larger systems. This system has 268 violations on record.