WaterVerge

Head-to-head water quality

Pittsburgh, PA vs San Antonio, TX

Side-by-side water quality comparison: Pittsburgh (Grade F) vs San Antonio (Grade F). Lead, PFAS, violations, and source-water contamination

Score breakdown

Each factor is shown as raw points (out of the maximum). Higher = better.

Factor
Pittsburgh
San Antonio
Better
Violations subscore / 45
0.0
0.0
Tie
Lead/Copper subscore / 20
20.0
16.0
Pittsburgh
Contaminant subscore / 20
12.0
10.1
Pittsburgh
Compliance subscore / 10
8.0
3.0
Pittsburgh
Source subscore / 5
4.0
4.0
Tie

Lead & copper at the tap

Lead and Copper Rule (LCR) 90th-percentile readings — the value that 10% of sampled homes exceed.

Factor
Pittsburgh
San Antonio
Better
Lead 90th-percentile (latest) · EPA action level: 15 µg/L
0.0 µg/L
0.0 µg/L
San Antonio
Copper 90th-percentile (latest) · EPA action level: 1.3 mg/L
1.5 mg/L
San Antonio

PFAS — "forever chemicals"

UCMR 5 testing, 2023–2025. Federal MCLs: PFOA + PFOS = 4 ng/L; HFPO-DA = 10 ng/L.

Factor
Pittsburgh
San Antonio
Better
PFAS analytes detected
0 of 30
4 of 30
Pittsburgh
PFAS exceeds federal MCL
No
No
Tie
PFAS hazard index · Sum of (max/MCL) across detected analytes; > 1 indicates exceedance

Violation history

SDWA enforcement actions — fewer is better.

Factor
Pittsburgh
San Antonio
Better
Violations (last 5 years)
151
86
San Antonio
Health-based violations (total)
44
25
San Antonio
Unresolved violations
138
212
Pittsburgh

Other contaminants tested

UCMR rounds 1–4 + UCMR 5 lithium. Maxima where data exists; "—" means not tested.

Factor
Pittsburgh
San Antonio
Better
Chromium-6 (max)
0.72 µg/L
1.80 µg/L
Pittsburgh
HAA5 (avg)
22.13 µg/L
3.96 µg/L
San Antonio
Manganese (max)
29.40 µg/L
6.40 µg/L
San Antonio
Strontium (max)
200.00 µg/L
9800.00 µg/L
Pittsburgh
1,4-Dioxane (max)
1.60 µg/L
0.58 µg/L
San Antonio
NDMA (max)
11.00 ng/L
Pittsburgh
Vanadium (max)
1.20 µg/L
33.00 µg/L
Pittsburgh
Chlorate (max)
370.00 µg/L
64.00 µg/L
San Antonio
Molybdenum (max)
1.30 µg/L
9.20 µg/L
Pittsburgh

Industrial proximity

Superfund National Priorities List + Toxic Release Inventory facilities within 10 miles of the city centroid.

Factor
Pittsburgh
San Antonio
Better
Superfund sites within 10 mi
1
2
Pittsburgh
TRI lbs to surface water within 10 mi (2023)
12,487
251
San Antonio

System size & source

Factor
Pittsburgh
San Antonio
Population served
802K
2.2M
Water source
Surface water
Purchased surface water
Number of water systems
16
18

See the full reports

Frequently asked

Which has better water — Pittsburgh or San Antonio?
Pittsburgh, PA scores higher (44.0 vs 33.1) on WaterVerge's 100-point methodology, earning a Grade F compared to San Antonio's Grade F. The score combines violation history, lead and copper levels, contaminant testing, monitoring compliance, and source-water type.
How is the WaterVerge water quality score calculated?
The grade combines five subscores: violation history (45 pts, weighted by recency and health-based severity), lead/copper 90th-percentile vs EPA action levels (20 pts), contaminant testing including PFAS, chromium-6, HAA5, NDMA, perchlorate, and Superfund/TRI proximity (20 pts), monitoring compliance (10 pts), and water-source-type risk (5 pts). Full methodology at /about/methodology.
Where does this water quality data come from?
From the EPA's public records: the SDWIS bulk download (violations + system info), UCMR rounds 1–5 (unregulated contaminant testing including PFAS, chromium-6, HAA5, NDMA, perchlorate, vanadium, lithium), the EPA Toxic Release Inventory (industrial polluters), the Superfund National Priorities List, the USGS Powell Domestic-Well Database (private-well chemistry), and the CDC Community Water Fluoridation system. Data is refreshed quarterly.