Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is San Sebastian, PR Tap Water Safe to Drink?

Graded F — but Copper and Chlorate were detected above EPA limits. Here's what's in the water and how to remove it. What to do ↓

2 contaminants over a legal limit
14.0 ppb lead, 90th percentile
35 unresolved violations
25K people served by 5 water systems

PWSID PR0003303 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
F 32.5 / 100

#99 of 101Puerto Rico cities
How we grade →

01The verdict: is San Sebastian water safe?

San Sebastian's drinking water has significant quality concerns based on EPA testing data. With a grade of F (32.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 5 water systems serve approximately 24,870 residents using surface water (rivers, lakes, or reservoirs).

The concern

Copper is over its legal limit

Measured at 1.79 mg/L against the EPA Action Level of 1.3 mg/L. The ledger below shows how far over — and which filter removes it.

See the measurement ↓
The good news

No forever chemicals detected

UCMR 5 laboratory testing found no PFAS compounds above detection thresholds in this system.

See PFAS results ↓
Keep watching

Lead is approaching its limit

Measured at 14.0 ppb — 93% of the 15 ppb limit. Within the rules, but with less headroom than you'd want.

See the ledger ↓

San Sebastian's drinking water received a grade of F (32.5 out of 100), indicating failing water quality. The city's 5 water systems serve approximately 24,870 residents using surface water.

Lead levels were measured at 14.0 ppb (90th percentile), which is within EPA limits but above recommended levels. PFAS testing under UCMR 5 found no detectable forever chemicals. The system has 671 violations on record, including 200 health-based violations. 35 remain unresolved.

San Sebastian ranks #99 out of 101 cities in Puerto Rico for water quality, placing it among the lowest-rated in the state. The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection. Haloacetic acid (HAA5) levels were elevated at 44.0 µg/L in UCMR 4 testing, though below the 60 µg/L EPA limit. Activated carbon filtration can help reduce these disinfection byproducts. Hexavalent chromium (chromium-6) was detected at 0.23 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration. While lead levels are within EPA limits, they are above the recommended 5 ppb threshold that health organizations consider ideal. A point-of-use filter adds an extra layer of protection. The system has seen 57 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

How the 32.5/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
0 / 45F
Lead & CopperLead at 14.0 ppb (90th percentile).
6 / 20F
ContaminantsNo PFAS compounds detected.
14.6 / 20C
ComplianceMonitoring and reporting compliance with EPA regulations.
8 / 10B
Source RiskWater source: Surface water.
4 / 5B

02What's in San Sebastian's water

Every contaminant flagged in San Sebastian, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

8 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%

Over Limit — EPA Action Level: 1.3 mg/L

Exceeds the EPA action level. Copper leaches from household plumbing — flush taps for 30 seconds before drinking, and consider a certified filter.
Exceeds Limit What to do →
Chlorate Disinfection Byproduct
310.0 µg/L 120% of limit
Manganese Inorganic
34.2 µg/L 68% of limit
Strontium Inorganic
434.8 µg/L 29% of limit
Vanadium Inorganic
2.28 µg/L 11% of limit
38 contaminants tested under EPA SDWIS, LCR and UCMR programs · 8 detected Contaminants without a federal MCL are shown against the strictest state or advisory level named in each row.

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 14.0 15 ppb Inorganic Near Limit
Copper (90th percentile) 1.79 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03San Sebastian's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 671 violations on record, including 200 health-based violations. 35 remain unresolved.

1 of the last ten years was clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

21 health-based in 10 yrs 126 monitoring & paperwork 12 still unresolved
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into San Sebastian's water quality assessment. Grade: F (32.5/100).
Violation1 drinking water violation recordedContaminants: Revised Total Coliform Rule.Resolved
Violation1 drinking water violation recordedContaminants: Revised Total Coliform Rule.Resolved
Violation1 drinking water violation recordedContaminants: Revised Total Coliform Rule.Resolved
Lead, 90th percentileppb · lower is better
0204060EPA action level · 15 ppb1992 — 5 ppb1993 — 3 ppb2000 — 7 ppb2001 — 2.9 ppb2002 — 3.5 ppb2003 — 2.4 ppb2004 — 2.3 ppb2005 — 2 ppb2006 — 0.80 ppb2009 — 6 ppb2010 — 6 ppb2011 — 6 ppb2012 — 6 ppb2013 — 6 ppb2014 — 6 ppb2015 — 6 ppb2016 — 6 ppb2019 — 44 ppb2023 — 14 ppb514199220022006201220162023

Up 9 ppb since 1992. Latest reading: 14 ppb (2023) — 93% of the action level. Sampled at higher-risk homes (90th percentile).

Copper, 90th percentilemg/L

1.8mg/L(2009)

One sampling round on record — 138% of the 1.3mg/L EPA action level. Sampled at higher-risk homes (90th percentile).

04Where San Sebastian's water comes from

San Sebastian's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Source

Surface Water

Rivers, lakes, or reservoirs — more exposed to runoff, agriculture, and seasonal swings than groundwater.

Treatment

Local treatment

Multi-barrier treatment: coagulation, sedimentation, filtration, and disinfection to meet EPA standards.

Distribution

5 systems

5 water systems, operated under local government ownership.

Delivery

24,870 people

Residents served across San Sebastian's service area.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards. These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge. The system is operated by local government ownership and serves approximately 24,870 people through 5 water systems.

System namePWSIDPopulationSource
SAN SEBASTIAN PR0003303 24,449 Surface Water
LAGO GUAJATACA PR0003772 11,187 Surface Water
WILFREDO VALENTIN PR0003435 929 Groundwater
ACUED. RURAL GUACIO PR0367013 340 Groundwater
ACUEDUCTO RURAL GUADALUPE MARTI PR0367053 81 Groundwater

Water bodies near San Sebastian

Canal Principal Diversion · stream Lago Guerrero Nr Isabela · lake Canal Principal Diversion Abv. Lago Guerrero · stream Rio Guajataca · river Lago Guajataca · lake

As a surface-water system, these water bodies may directly influence San Sebastian's drinking water supply.

05How San Sebastian compares

Scores for nearby Puerto Rico cities on one line, with the average marked.

Mayaguez
42.1 · F
San Juan
38.5 · F
Toa Alta
38.5 · F
Aguadilla
38.3 · F
Ponce
34.9 · F
San Sebastian (this city)
32.5 · F

dashed line = Puerto Rico average (39/100)

San Sebastian scores 32.5/100below the Puerto Rico average of 39/100.

San Sebastian Municipio water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

06What to do at home

Steps matched to what testing actually found in San Sebastian's water — not generic advice.

Because of lead

Filter drinking & cooking water

NSF-certified water filter. Lead detected at 14.0 ppb

Compare tested filters →
Because lead was detected

Flush taps & check your service line

Lead leaches from pipes as water sits. Run cold water 30 seconds before drinking (especially mornings), and ask the utility whether your address still has a lead service line.

Lead risks explained →
Stay informed

Watch for San Sebastian alerts

We refresh EPA data monthly and surface new violations, advisories, and boil-water notices for your county on this page.

All water alerts →

Frequently asked questions

Is San Sebastian, PR tap water safe to drink?

San Sebastian's water quality earned a grade of F (32.5/100). Significant issues have been found. A water filter is strongly recommended. The city ranks #99 out of 101 cities tested in Puerto Rico.

What contaminants are in San Sebastian's water?

Lead was measured at 14.0 ppb (90th percentile). No PFAS compounds were detected. 671 violations are on record.

How is San Sebastian's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in San Sebastian?

While lead levels are within EPA limits, a filter adds extra protection. Based on current data, basic filtration should suffice for additional peace of mind.

Where does San Sebastian's water come from?

San Sebastian's water is sourced from Surface water. The city has 5 water systems serving approximately 24,870 residents.

What health violations has San Sebastian's water system had?

San Sebastian has 200 health-based violations on record. The most recent violation was recorded in December 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 35 violations remain unresolved.

How does San Sebastian's water compare to other cities?

San Sebastian ranks #99 out of 101 cities in Puerto Rico (better than 2% of state cities) and #15273 out of 15382 cities nationally (1th percentile). The grade of F reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About San Sebastian, PR: San Sebastián is a town and municipality of Puerto Rico located in the northwestern region of the island, south of Isabela, Quebradillas and Camuy; north of Las Marías; east of Moca and Añasco; and west of Lares. San Sebastián is spread over twenty-four barrios and San Sebastián Pueblo. It is a principal city of the Aguadilla-Isabela-San Sebastián Metropolitan Statistical Area. Median household income $18,806 · median home value $105,299 · median age 43.9 · 59.3% homeowners. Wikipedia → Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.