WaterVerge

Is Niceville, FL Tap Water Safe to Drink?

Graded A-, with 5 unresolved violations on record. See what was cited — and what it means for your tap. What to do next ↓

42K residents served 3 water systems PWSID: FL1460147
Overall Score
85.5 / 100
Violations
5 active
Last Updated
May 2026
Source
Groundwater
#93 of 388 in Florida Top 33% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
A-GRADE
Water Quality Grade
85.5/100
waterverge.com
A- 85.5/100

Niceville, FL — Water Quality Report

Niceville's drinking water received a grade of A- (85.5 out of 100), indicating good water quality. The city's 3 water systems serve approximately 42,214 residents using groundwater.

Lead levels were measured at 4.6 ppb (90th percentile), well within EPA limits. PFAS testing under UCMR 5 found no detectable forever chemicals.

The system has 27 violations on record, including 5 health-based violations. 5 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Niceville's water

Niceville ranks #93 out of 388 cities in Florida for water quality, placing it above average in the state.

Niceville relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

Hexavalent chromium (chromium-6) was detected at 0.26 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

Quality Breakdown

Water quality score

See methodology →
85.5 out of 100 Grade A-
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
34.5/45
B
Historical violation record including health-based and monitoring violations.
Lead & Copper
18/20
A
Lead at 4.6 ppb (90th percentile).
Contaminants
20/20
A
No PFAS compounds detected.
Compliance
8/10
B
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Niceville, FL water safe to drink?

Concerns Identified

Niceville's drinking water has significant quality concerns based on EPA testing data. With a grade of A- (85.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 3 water systems serve approximately 42,214 residents using groundwater (wells).

5
Active Violations
4.6 ppb
Lead (90th %ile)
None
PFAS Detected
10 events
Disaster History

Recent water quality updates for Niceville

A timeline of significant water quality events, violations, and data updates.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Niceville's water quality assessment. Grade: A- (85.5/100).

Violation
2 drinking water violations recorded

1 health-based. Contaminants: LEAD AND COPPER RULE REVISIONS.

Disaster
HURRICANE HELENE

Federal disaster declaration (FEMA DR-4828). Hurricane event — may have impacted local water infrastructure.

Disaster
HURRICANE IAN

Federal disaster declaration (FEMA DR-4673). Hurricane event — may have impacted local water infrastructure.

Violation
2 drinking water violations recorded

Contaminants: TTHM, Total Haloacetic Acids (HAA5).

Violation
1 drinking water violation recorded

Contaminants: E. COLI.

Key contaminant findings

Based on the most recent EPA sampling data for Niceville's water supply.

Lead Within Limits
Detected: 4.6 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Violation history

Niceville's water system has 27 total violations on record, including 5 health-based violations. 5 remain unresolved. 2 violations were issued in the last 5 years.

TTRPTMRMCL
Most recent violations:
Feb 2025 LEAD AND COPPER RULE REVISIONS Open
Feb 2025 LEAD AND COPPER RULE REVISIONS Open
Jul 2015 TTHM Resolved
Jul 2015 Total Haloacetic Acids (HAA5) Resolved
Jun 2014 E. COLI Resolved

Flood & environmental risk

Okaloosa County has experienced 10 federally declared disasters since 2017. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Juniper Creek.

HURRICANE HELENE
Hurricane FEMA DR-4828
HURRICANE IAN
Hurricane FEMA DR-4673
TROPICAL STORM IAN
Hurricane FEMA DR-3584

Where does Niceville's water come from?

Niceville's drinking water comes from groundwater (wells), supplied by 3 water systems serving approximately 42,214 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Juniper Creek (river).

What Niceville residents can do

Install a water filter

Recommended: NSF-certified water filter. This addresses the specific contaminants found in Niceville's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Flush your taps

Run cold water for 30 seconds before drinking, especially in the morning. Lead and copper leach from household plumbing when water sits in pipes.

Monitor alerts during storms

Niceville's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
4.6 ppb
EPA Action Level: 15 ppb · 31% of limit
Safe Level
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
0.9 µg/L
EPA MCL: 60 µg/L · 2% of limit
Within LimitUCMR 4 DataHAA6Br: 1.1 µg/LHAA9: 1.9 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.26 µg/L
CA MCL (no federal MCL): 10 µg/L · 3% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
345.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 23% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
2.5 µg/L
EPA Secondary MCL: 50 µg/L · 5% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Detected
0.35 µg/L
EPA Short-term HA: 21 µg/L · 2% of limit
DetectedUCMR 3 Data
Molybdenum
Inorganic
Detected
4.60 µg/L
EPA Lifetime HA: 40 µg/L · 12% of limit
DetectedUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
0
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

27
Total violations
5
Health-based
5
Active / unresolved
Feb 2025
Most recent violation
Compliance Record

Violations & advisories

27 Total
5 Active
5 Health-based
22 Resolved
2 SNC
Violations by category
Total Coliform Rule
18
Lead and Copper Rule Revisions
2
Stage 2 Disinfectants and Disinfection Byproducts Rule
2
Ground Water Rule
1
Radionuclides and Revised Rad Rule
1
Feb 2025 Active
LEAD AND COPPER RULE REVISIONS
Treatment Technique
Health-Based Health 0
Feb 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Active
Compliance Violation
Monitoring 0
Active
Compliance Violation
Monitoring 0
Active
Compliance Violation
Monitoring 0
Jul 2015 Resolved
TTHM
Monitoring & Reporting
SNC Monitoring & Reporting Resolved Sep 2015
Jul 2015 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
SNC Monitoring & Reporting Resolved Sep 2015
Jun 2014 Resolved
E. COLI
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2014
Oct 2013 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Oct 2013
Feb 2013 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Feb 2013
Nov 2010 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Nov 2010
Apr 2010 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Apr 2010
Mar 2009 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2009
Oct 2007 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Oct 2007
Jun 2005 Resolved
Coliform (TCR)
Max Contaminant Level
Health-Based Health Resolved Jun 2005
Feb 2004 Resolved
Coliform (TCR)
Max Contaminant Level
Health-Based Health Resolved Feb 2004
Aug 2003 Resolved
Coliform (TCR)
Max Contaminant Level
Health-Based Health Resolved Aug 2003
Mar 2003 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2003
Jul 2001 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 2001
Feb 1996 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Feb 1996
Showing 20 of 27 violations
Industrial pollution

Top industrial polluters within 10 miles of Niceville

Industrial polluters nearby

Reported releases to surface water by facilities near Niceville, ranked by pounds discharged annually.

FacilityTop chemicalTo surface water (lbs/yr)Distance
U.S. DOD USAF EGLIN AFB FL
Other · US DEPARTMENT OF DEFENSE
EGLIN AFB, FL32542
4.0 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Environmental Risk

Drought conditions

D3 — extreme drought

Okaloosa County is currently in D3 (extreme drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

14
Weeks at D2+ (current streak)
23.1%
Months in D2+ (last 30y)
14
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

10
Declared disasters
Sep 2024
Most recent
Hurricane
Most common type

Okaloosa County has experienced 10 federally declared disasters since 2017. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Sep 2024
HURRICANE HELENE
Hurricane FEMA #4828
Sep 2022
HURRICANE IAN
Hurricane FEMA #4673
Sep 2022
TROPICAL STORM IAN
Hurricane FEMA #3584
Aug 2021
TROPICAL STORM FRED
Hurricane FEMA #3562
Sep 2020
HURRICANE SALLY
Hurricane FEMA #4564
Sep 2020
HURRICANE SALLY
Hurricane FEMA #3546

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 4.6 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 7.0 ppb from 1992 (9.0 ppb) to 2023 (2.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Local Government
Population Served
42,214
Water Systems
3
Water Source

Where Niceville's water comes from

Groundwater

Niceville's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 42,214 people through 3 water systems.

Local Hydrology

Water bodies near Niceville

Niceville is located near 1 notable water body. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Juniper Creek
river
Infrastructure

Water systems serving Niceville

System Name PWSID Population Source
NICEVILLE, CITY OF FL1460147 21,451 GW
OKALOOSA COUNTY BLUEWATER BAY-RAINTREE FL1460775 17,592 GW
NORTH BAY WATER SYSTEM FL1664019 3,171 GW
Regional Comparison

How Niceville compares

Full Florida rankings →

Niceville's score of 85.5/100 is above the average of 50/100 among major Florida cities. It outscores 10 of 10 nearby cities.

Niceville (this city)
85.5
Miami
35
Orlando
36.8
Tampa
34.4
Florida avg
50
City Profile

About Niceville, FL

Wikipedia →

Niceville is a city in Okaloosa County, Florida, United States, located near Eglin Air Force Base on Boggy Bayou that opens into Choctawhatchee Bay. It is part of the Crestview-Fort Walton Beach-Destin, Florida Metropolitan Statistical Area. The population was 15,772 at the 2020 census, up from 12,749 at the 2010 census.

Economic Profile
$92,345
Median Income
$351,220
Median Home Value
$1,511/mo
Median Rent
1.2%
Unemployment
Community
39.1
Median Age
424
People / sq mi
37.6%
College Educated
70.2%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Niceville, FL tap water safe to drink?

Niceville's water quality earned a grade of A- (85.5/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #93 out of 388 cities tested in Florida.

What contaminants are in Niceville's water?

Lead was measured at 4.6 ppb (90th percentile). No PFAS compounds were detected. 27 violations are on record.

How is Niceville's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Niceville?

Based on current data, basic filtration should suffice for additional peace of mind.

Where does Niceville's water come from?

Niceville's water is sourced from Groundwater. The city has 3 water systems serving approximately 42,214 residents.

What health violations has Niceville's water system had?

Niceville has 5 health-based violations on record. The most recent violation was recorded in February 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 5 violations remain unresolved.

Is Niceville's groundwater at risk of contamination?

Niceville uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 27 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Niceville's water compare to other cities?

Niceville ranks #93 out of 388 cities in Florida (better than 76% of state cities) and #5251 out of 15744 cities nationally (67th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.