Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is Mount Vernon (C), NY Tap Water Safe to Drink?

Graded A- — but Manganese was detected above EPA limits. Here's what's in the water and how to remove it. What to do ↓

1 contaminant over a legal limit
7.1 ppb lead, 90th percentile
1 unresolved violation
74K people served by 1 water system

PWSID NY5903441 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
A 88 / 100

#324 of 810New York cities
How we grade →

01The verdict: is Mount Vernon (C) water safe?

Mount Vernon (C)'s tap water meets most EPA standards but has areas that warrant attention. With a grade of A- (88/100), some contaminant levels or compliance issues suggest that residents may benefit from additional filtration. The city's 1 water system serves approximately 73,893 residents using surface water (rivers, lakes, or reservoirs).

The concern

Manganese is over its legal limit

Measured at 57.8 µg/L against the EPA Secondary MCL of 50 µg/L. The ledger below shows how far over — and which filter removes it.

See the measurement ↓
The good news

No forever chemicals detected

UCMR 5 laboratory testing found no PFAS compounds above detection thresholds in this system.

See PFAS results ↓
Keep watching

HAA5 is approaching its limit

Measured at 40.5 µg/L — 68% of the 60 µg/L limit. Within the rules, but with less headroom than you'd want.

See the ledger ↓

Mount Vernon (C)'s drinking water received a grade of A- (88 out of 100), indicating good water quality. The city's 1 water system serves approximately 73,893 residents using purchased surface water.

Lead levels were measured at 7.1 ppb (90th percentile), which is within EPA limits but above recommended levels. PFAS testing under UCMR 5 found no detectable forever chemicals. The system has 3 violations on record, including 2 health-based violations. 1 remains unresolved.

Mount Vernon (C) ranks #324 out of 810 cities in New York for water quality, placing it mid-range in the state. The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection. Haloacetic acid (HAA5) levels were elevated at 40.5 µg/L in UCMR 4 testing, though below the 60 µg/L EPA limit. Activated carbon filtration can help reduce these disinfection byproducts. Hexavalent chromium (chromium-6) was detected at 0.05 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration. While lead levels are within EPA limits, they are above the recommended 5 ppb threshold that health organizations consider ideal. A point-of-use filter adds an extra layer of protection.

How the 88/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
44.4 / 45A
Lead & CopperLead at 7.1 ppb (90th percentile).
16 / 20B
ContaminantsNo PFAS compounds detected.
18.6 / 20A
ComplianceMonitoring and reporting compliance with EPA regulations.
5 / 10D
Source RiskWater source: Purchased surface water.
4 / 5B

02What's in Mount Vernon (C)'s water

Every contaminant flagged in Mount Vernon (C), on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

6 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%
Manganese Inorganic
57.8 µg/L 116% of limit
Chlorate Disinfection Byproduct
24.0 µg/L 11% of limit
Strontium Inorganic
24.0 µg/L 2% of limit
36 contaminants tested under EPA SDWIS, LCR and UCMR programs · 6 detected Contaminants without a federal MCL are shown against the strictest state or advisory level named in each row.

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 7.1 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Mount Vernon (C)'s ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 3 violations on record, including 2 health-based violations. 1 remains unresolved.

All ten of the last ten years were clean — no EPA violations recorded for Mount Vernon (C).

UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Mount Vernon (C)'s water quality assessment. Grade: A- (88/100).
DisasterSEVERE STORM AND FLOODINGFederal disaster declaration (FEMA DR-4755). Flood event — may have impacted local water infrastructure.
DisasterREMNANTS OF HURRICANE IDAFederal disaster declaration (FEMA DR-4615). Hurricane event — may have impacted local water infrastructure.
Violation1 drinking water violation recorded1 health-based. Contaminants: Coliform (TCR).Resolved
Violation1 drinking water violation recorded1 health-based. Contaminants: Lead and Copper Rule.Resolved
Lead, 90th percentileppb · lower is better
020406080EPA action level · 15 ppb1992 — 61 ppb1997 — 13 ppb1998 — 12 ppb1999 — 10 ppb2000 — 15 ppb2001 — 6.4 ppb2006 — 6.8 ppb2009 — 11 ppb2012 — 14 ppb2015 — 5.5 ppb2018 — 3.6 ppb2021 — 3.1 ppb2024 — 2.5 ppb2027 — 7.1 ppb617.1199219992006201520242027

Down 54 ppb since 1992. Latest reading: 7.1 ppb (2027) — 47% of the action level. Sampled at higher-risk homes (90th percentile).

04Where Mount Vernon (C)'s water comes from

Mount Vernon (C)'s drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Source

Purchased Surface Water

Rivers, lakes, or reservoirs — more exposed to runoff, agriculture, and seasonal swings than groundwater.

Treatment

Wholesale supplier

Multi-barrier treatment: coagulation, sedimentation, filtration, and disinfection to meet EPA standards.

Distribution

1 system

1 water system, operated under local government ownership.

Delivery

73,893 people

Residents served across Mount Vernon (C)'s service area.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards. These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge. The system is operated by local government ownership and serves approximately 73,893 people through 1 water system.

System namePWSIDPopulationSource
MOUNT VERNON WATER DEPARTMENT NY5903441 73,893 Purchased Surface Water

Water bodies near Mount Vernon (C)

Bronx River · river Hudson River · river

As a surface-water system, these water bodies may directly influence Mount Vernon (C)'s drinking water supply.

05Pressure on Mount Vernon (C)'s watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Flood & storm history

Recurring — declared disasters

10 federal disaster declarations on record for Westchester County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

SEVERE STORM AND FLOODING Jan 2024 · DR-4755
REMNANTS OF HURRICANE IDA Sep 2021 · DR-4615
REMNANTS OF HURRICANE IDA Sep 2021 · DR-3572

Drought

D2 — severe drought

Westchester County is in D2 (severe drought) per the U.S. Drought Monitor (week of Jul 2026). Drought can raise disinfection-byproduct levels and taste/odor issues as utilities draw from lower reservoirs.

Current streak at D2+ severity4 wks
Weeks at D2+ in the last 5 years4 wks
Months in D2+ over the last 30 years11.6%

06How Mount Vernon (C) compares

Scores for nearby New York cities on one line, with the average marked.

New York (C)
89 · A-
Mount Vernon (C) (this city)
88 · A-
Smithtown (T)
84.8 · B+
Islip (T)
71.8 · B-

dashed line = New York average (78/100)

Mount Vernon (C) scores 88/100above the New York average of 78/100. It outscores 8 of 10 nearby cities. Full New York rankings →

Westchester water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Mount Vernon (C)'s water — not generic advice.

Because of lead

Filter drinking & cooking water

Basic carbon filter for extra protection. Lead detected at 7.1 ppb

Compare tested filters →
Because lead was detected

Flush taps & check your service line

Lead leaches from pipes as water sits. Run cold water 30 seconds before drinking (especially mornings), and ask the utility whether your address still has a lead service line.

Lead risks explained →
Stay informed

Watch for Mount Vernon (C) alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Mount Vernon (C), NY tap water safe to drink?

Mount Vernon (C)'s water quality earned a grade of A- (88/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #324 out of 810 cities tested in New York.

What contaminants are in Mount Vernon (C)'s water?

Lead was measured at 7.1 ppb (90th percentile). No PFAS compounds were detected. 3 violations are on record.

How is Mount Vernon (C)'s water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Mount Vernon (C)?

While lead levels are within EPA limits, a filter adds extra protection. Based on current data, basic filtration should suffice for additional peace of mind.

Where does Mount Vernon (C)'s water come from?

Mount Vernon (C)'s water is sourced from Purchased surface water. The city has 1 water system serving approximately 73,893 residents.

What health violations has Mount Vernon (C)'s water system had?

Mount Vernon (C) has 2 health-based violations on record. The most recent violation was recorded in August 2015. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 1 violation remains unresolved.

How does Mount Vernon (C)'s water compare to other cities?

Mount Vernon (C) ranks #324 out of 810 cities in New York (better than 60% of state cities) and #3649 out of 15382 cities nationally (76th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Mount Vernon (C), NY: Median household income $75,511 · median home value $442,434 · median age 41.4 · 39.8% homeowners · 34.1% college educated. Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.