WaterVerge

Is Monticello, KY Tap Water Safe to Drink?

Graded A- — but Chlorate was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

21K residents served 1 water system PWSID: KY1160291
Overall Score
86.5 / 100
Violations
6 active
Last Updated
May 2026
Source
Surface water
#75 of 246 in Kentucky Top 30% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
A-GRADE
Water Quality Grade
86.5/100
waterverge.com
A- 86.5/100

Monticello, KY — Water Quality Report

Monticello's drinking water received a grade of A- (86.5 out of 100), indicating good water quality. The city's 1 water system serves approximately 21,000 residents using surface water.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. PFAS testing under UCMR 5 found no detectable forever chemicals.

The system has 22 violations on record, including 7 health-based violations. 6 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Monticello's water

Monticello ranks #75 out of 246 cities in Kentucky for water quality, placing it mid-range in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

Hexavalent chromium (chromium-6) was detected at 0.11 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

Quality Breakdown

Water quality score

See methodology →
86.5 out of 100 Grade A-
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
40.1/45
B
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.0 ppb (90th percentile).
Contaminants
17.4/20
B
No PFAS compounds detected.
Compliance
5/10
D
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Surface water.
Water Safety

Is Monticello, KY water safe to drink?

Concerns Identified

Monticello's drinking water has significant quality concerns based on EPA testing data. With a grade of A- (86.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 21,000 residents using surface water (rivers, lakes, or reservoirs).

6
Active Violations
0.0 ppb
Lead (90th %ile)
None
PFAS Detected
3 events
Disaster History

Recent water quality updates for Monticello

A timeline of significant water quality events, violations, and data updates.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Monticello's water quality assessment. Grade: A- (86.5/100).

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Violation
1 drinking water violation recorded

1 health-based. Contaminants: Revised Total Coliform Rule.

Disaster
HURRICANE KATRINA

Federal disaster declaration (FEMA DR-3231). Hurricane event — may have impacted local water infrastructure.

Disaster
SEVERE STORMS & FLOODING

Federal disaster declaration (FEMA DR-893). Flood event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Monticello's water supply.

Lead Within Limits
Detected: 0.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Violation history

Monticello's water system has 22 total violations on record, including 7 health-based violations. 6 remain unresolved. 2 violations were issued in the last 5 years.

OtherMONTTMCLMR
Most recent violations:
Jul 2024 Consumer Confidence Rule Open
Jun 2024 Revised Total Coliform Rule Resolved
Jul 2020 Revised Total Coliform Rule Open
Jan 2011 TTHM Resolved
Jul 2010 TTHM Resolved

Flood & environmental risk

Wayne County has experienced 3 federally declared disasters since 1972. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Beaver Creek.

HURRICANE KATRINA
Hurricane FEMA DR-3231
SEVERE STORMS & FLOODING
Flood FEMA DR-893
HEAVY RAINS & FLOODING
Flood FEMA DR-332

Where does Monticello's water come from?

Monticello's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 1 water system serving approximately 21,000 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Beaver Creek (river).

What Monticello residents can do

Install a water filter

Recommended: NSF-certified water filter. This addresses the specific contaminants found in Monticello's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Monticello's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.0 ppb
EPA Action Level: 15 ppb · 0% of limit
Safe Level
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
21.8 µg/L
EPA MCL: 60 µg/L · 36% of limit
Within LimitUCMR 4 DataHAA6Br: 4.6 µg/LHAA9: 26.4 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.11 µg/L
CA MCL (no federal MCL): 10 µg/L · 1% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
113.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 8% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
9.3 µg/L
EPA Secondary MCL: 50 µg/L · 19% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Detected
0.21 µg/L
EPA Short-term HA: 21 µg/L · 1% of limit
DetectedUCMR 3 Data
Chlorate
Disinfection Byproduct
Over HA
516.0 µg/L
EPA Lifetime HA: 210 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
0
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

22
Total violations
7
Health-based
6
Active / unresolved
Jul 2024
Most recent violation
Compliance Record

Violations & advisories

22 Total
6 Active
7 Health-based
16 Resolved
Violations by category
Stage 1 Disinfectants and Disinfection Byproducts Rule
6
Inorganic Chemicals
5
Consumer Confidence Rule
2
Revised Total Coliform Rule
2
Public Notice Rule and Revised PN Rule
1
Jul 2024 Active
Consumer Confidence Rule
Other Violation 0
Jul 2020 Active
Revised Total Coliform Rule
Treatment Technique
Health-Based Health 0
Jul 2008 Active
Public Notice
Other Violation 0
Jul 2006 Active
Consumer Confidence Rule
Other Violation 0
Mar 2002 Active
Interim Enhanced Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Jun 2024 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Jun 2024
Jan 2011 Resolved
TTHM
Max Contaminant Level
Health-Based Health Resolved Mar 2011
Jul 2010 Resolved
TTHM
Max Contaminant Level
Health-Based Health Resolved Sep 2010
Apr 2010 Resolved
Total Haloacetic Acids (HAA5)
Max Contaminant Level
Health-Based Health Resolved Jun 2010
Jul 2003 Resolved
CARBON, TOTAL
Treatment Technique
Health-Based Health Resolved Sep 2003
Apr 2003 Resolved
CARBON, TOTAL
Treatment Technique
Health-Based Health Resolved Jun 2003
Oct 2002 Resolved
CARBON, TOTAL
Treatment Technique
Health-Based Health Resolved Dec 2002
Jul 1995 Resolved
Gross Alpha, Excl. Radon and U
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1999
Jun 1995 Resolved
Surface Water Treatment Rule
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 1995
Jul 1986 Resolved
Cadmium
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 1987
Jul 1986 Resolved
Barium
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 1987
Jul 1986 Resolved
Arsenic
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 1987
Jul 1986 Resolved
Mercury
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 1987
Jul 1986 Resolved
Selenium
Monitoring & Reporting
Monitoring & Reporting Resolved Jul 1987
Showing 20 of 22 violations
Environmental Risk

Drought conditions

D2 — severe drought

Wayne County is currently in D2 (severe drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

4
Weeks at D2+ (current streak)
11.6%
Months in D2+ (last 30y)
4
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

3
Declared disasters
Sep 2005
Most recent
Flood
Most common type

Wayne County has experienced 3 federally declared disasters since 1972. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Sep 2005
HURRICANE KATRINA
Hurricane FEMA #3231
Jan 1991
SEVERE STORMS & FLOODING
Flood FEMA #893
May 1972
HEAVY RAINS & FLOODING
Flood FEMA #332

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 3.1 ppb from 1992 (3.1 ppb) to 2024 (0.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Surface Water
Operator
Local Government
Population Served
21,000
Water Systems
1
Water Source

Where Monticello's water comes from

Surface Water

Monticello's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 21,000 people through 1 water system.

Local Hydrology

Water bodies near Monticello

Monticello is located near 1 notable water body. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Beaver Creek
river
Infrastructure

Water systems serving Monticello

System Name PWSID Population Source
MONTICELLO WATER & SEWER COMMISSION KY1160291 21,000 SW
Regional Comparison

How Monticello compares

Full Kentucky rankings →

Monticello's score of 86.5/100 is above the average of 80/100 among major Kentucky cities. It outscores 9 of 10 nearby cities.

Monticello (this city)
86.5
Louisville
82.2
Ft. Thomas
86.8
Owensboro
85.1
Kentucky avg
80
City Profile

About Monticello, KY

Wikipedia →

Monticello is a city in Wayne County, Kentucky, United States. It is the seat of its county. Its population was 5,753 at the time of the 2020 United States census.

Economic Profile
$43,353
Median Income
$137,745
Median Home Value
$739/mo
Median Rent
4.2%
Unemployment
Community
40
Median Age
366
People / sq mi
12.7%
College Educated
60.7%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Monticello, KY tap water safe to drink?

Monticello's water quality earned a grade of A- (86.5/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #75 out of 246 cities tested in Kentucky.

What contaminants are in Monticello's water?

Lead was measured at 0.0 ppb (90th percentile). No PFAS compounds were detected. 22 violations are on record.

How is Monticello's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Monticello?

Based on current data, basic filtration should suffice for additional peace of mind.

Where does Monticello's water come from?

Monticello's water is sourced from Surface water. The city has 1 water system serving approximately 21,000 residents.

What health violations has Monticello's water system had?

Monticello has 7 health-based violations on record. The most recent violation was recorded in July 2024. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 6 violations remain unresolved.

How does Monticello's water compare to other cities?

Monticello ranks #75 out of 246 cities in Kentucky (better than 70% of state cities) and #4634 out of 15744 cities nationally (71th percentile). The grade of A- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.