Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is Monaca, PA Tap Water Safe to Drink?

Graded B-, with 5 unresolved violations on record. See what was cited — and what it means for your tap. What to do ↓

0 contaminants over a legal limit
3.4 ppb lead, 90th percentile · low
5 unresolved violations
7K people served by 1 water system

PWSID PA5040039 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
B 73.8 / 100

#154 of 559Pennsylvania cities
How we grade →

01The verdict: is Monaca water safe?

Monaca's drinking water has significant quality concerns based on EPA testing data. With a grade of B- (73.8/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 6,500 residents using groundwater (wells).

The concern

5 unresolved violations on record

EPA records show open compliance items for this system. Most are administrative, but unresolved items are worth watching.

See what was cited ↓
The good news

Lead is well under the limit

90th-percentile lead is 3.4 ppb — beneath the 15 ppb federal action level and under the 5 ppb watch threshold.

See the trend ↓
Keep watching

PFHxS is approaching its limit

Measured at 0.0111 µg/L — 120% of the 0.004 µg/L limit. Within the rules, but with less headroom than you'd want.

See the ledger ↓

Monaca's drinking water received a grade of B- (73.8 out of 100), indicating fair water quality. The city's 1 water system serves approximately 6,500 residents using groundwater.

Lead levels were measured at 3.4 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 2 PFAS compounds in the water supply. The system has 136 violations on record, including 4 health-based violations. 5 remain unresolved.

Monaca ranks #154 out of 559 cities in Pennsylvania for water quality, placing it mid-range in the state. Monaca relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff. PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

How the 73.8/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
25.8 / 45D
Lead & CopperLead at 3.4 ppb (90th percentile).
18 / 20A
Contaminants2 PFAS compounds detected.
15 / 20B
ComplianceMonitoring and reporting compliance with EPA regulations.
10 / 10A
Source RiskWater source: Groundwater.
5 / 5A

02What's in Monaca's water

Every contaminant flagged in Monaca, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

3 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%

Near MCL — EPA MCL: 0.004 µg/L

Detected within current EPA limits. PFAS persist indefinitely in the environment and accumulate in the body over time — an activated carbon or reverse osmosis filter reduces exposure for those who want extra precaution.
Detected What to do →
31 contaminants tested under EPA SDWIS, LCR and UCMR programs · 3 detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 3.4 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS 0.007 HI µg/L PFAS Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS 0.011 HI µg/L PFAS Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Monaca's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 136 violations on record, including 4 health-based violations. 5 remain unresolved.

3 of the last ten years were clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

4 health-based in 10 yrs 38 monitoring & paperwork 3 still unresolved
PFAS2 PFAS "forever chemical" compounds detectedDetected at levels within current EPA limits. PFAS persist indefinitely in the environment.
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Monaca's water quality assessment. Grade: B- (73.8/100).
Violation1 drinking water violation recordedContaminants: Lead and Copper Rule.Open
Violation1 drinking water violation recorded1 health-based. Contaminants: Revised Total Coliform Rule.Open
Violation1 drinking water violation recordedContaminants: Groundwater Rule.Resolved
DisasterHURRICANE SANDYFederal disaster declaration (FEMA DR-3356). Hurricane event — may have impacted local water infrastructure.
Lead, 90th percentileppb · lower is better
05101520EPA action level · 15 ppb1992 — 5 ppb1994 — 7 ppb1995 — 5 ppb1998 — 2 ppb2001 — 8 ppb2004 — 1 ppb2007 — 7.9 ppb2010 — 12 ppb2013 — 0 ppb2016 — 5.9 ppb2019 — 6.1 ppb2022 — 3.6 ppb2025 — 3.4 ppb53.419921998200720162025

Down 1.6 ppb since 1992. Latest reading: 3.4 ppb (2025) — 22% of the action level. Sampled at higher-risk homes (90th percentile).

04Where Monaca's water comes from

Monaca's drinking water is drawn from underground aquifers through wells.

Source

Groundwater

Underground aquifers reached by wells — naturally filtered, but can carry minerals like arsenic and nitrate.

Treatment

Local treatment

Groundwater generally needs less treatment — typically disinfection and, where needed, mineral removal.

Distribution

1 system

1 water system, operated under local government ownership.

Delivery

6,500 people

Residents served across Monaca's service area.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals. Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds. The system is operated by local government ownership and serves approximately 6,500 people through 1 water system.

System namePWSIDPopulationSource
MONACA BORO WATER DEPT PA5040039 6,500 Groundwater

Water bodies near Monaca

Ohio River At Sewickley · river Ohio River (Lower Pool) At Sewickley · river Connoquenessing Creek Near Zelienople · river Beaver River At Beaver Falls · river Raccoon Creek At Moffatts Mill · river

These water bodies shape the regional watershed and can indirectly affect groundwater quality.

05Pressure on Monaca's watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Industrial discharge

Present — monitored

5 facilities within 10 miles reported 3k lb released to surface water in the latest EPA Toxics Release Inventory. Proximity doesn't equal tap contamination — treatment and hydrology decide — but it's pressure on the watershed.

LIBERTAS COPPER LLC — copper and copper compounds 1k lb · 8.0 mi
BASF CORP — tert-butyl alcohol 873 lb · 4.1 mi
ALLEGHENY & TSINGSHAN STAINLESS LLC — manganese compounds 597 lb · 9.8 mi
+ 2 more facilities

Flood & storm history

Recurring — declared disasters

6 federal disaster declarations on record for Beaver County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

HURRICANE SANDY Oct 2012 · DR-3356
HURRICANE KATRINA Sep 2005 · DR-3235
TROPICAL DEPRESSION IVAN Sep 2004 · DR-1557

06How Monaca compares

Scores for nearby Pennsylvania cities on one line, with the average marked.

Mcmurray
86.8 · A-
Philadelphia
79.8 · B
Monaca (this city)
73.8 · B-
Greensburg
46.7 · D
Pittsburgh
44 · F
Bryn Mawr
34.2 · F

dashed line = Pennsylvania average (49/100)

Monaca scores 73.8/100above the Pennsylvania average of 49/100. It outscores 8 of 10 nearby cities. Full Pennsylvania rankings →

Beaver water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Monaca's water — not generic advice.

Because of pfas

Filter drinking & cooking water

Activated carbon or reverse osmosis filter. 2 PFAS compounds detected

Compare tested filters →
Because lead was detected

Flush taps & check your service line

Lead leaches from pipes as water sits. Run cold water 30 seconds before drinking (especially mornings), and ask the utility whether your address still has a lead service line.

Lead risks explained →
Stay informed

Watch for Monaca alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Monaca, PA tap water safe to drink?

Monaca's water quality earned a grade of B- (73.8/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #154 out of 559 cities tested in Pennsylvania.

What contaminants are in Monaca's water?

Lead was measured at 3.4 ppb (90th percentile). 2 PFAS compounds were detected. 136 violations are on record.

How is Monaca's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Monaca?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Monaca's water come from?

Monaca's water is sourced from Groundwater. The city has 1 water system serving approximately 6,500 residents.

What health violations has Monaca's water system had?

Monaca has 4 health-based violations on record. The most recent violation was recorded in September 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 5 violations remain unresolved.

Is Monaca's groundwater at risk of contamination?

Monaca uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 136 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Monaca's water compare to other cities?

Monaca ranks #154 out of 559 cities in Pennsylvania (better than 72% of state cities) and #9876 out of 15382 cities nationally (36th percentile). The grade of B- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Monaca, PA: Median household income $62,125 · median home value $148,691 · median age 39.3 · 60.9% homeowners · 24% college educated. Service area: 1 ZIP code across Beaver.
Show ZIP codes 15061
Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.