WaterVerge

Is Medina, OH Tap Water Safe to Drink?

Graded C+ — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

73K residents served 6 water systems PWSID: OH5201903
Overall Score
68.7 / 100
Violations
25 active
Last Updated
May 2026
Source
Purchased surface water
#424 of 511 in Ohio Top 70% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
C+GRADE
Water Quality Grade
68.7/100
waterverge.com
C+ 68.7/100

Medina, OH — Water Quality Report

Medina's drinking water received a grade of C+ (68.7 out of 100), indicating fair water quality. The city's 6 water systems serve approximately 73,148 residents using purchased surface water.

Lead levels were measured at 1.3 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 138 violations on record, including 15 health-based violations. 25 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Medina's water

Medina ranks #424 out of 511 cities in Ohio for water quality, placing it among the lowest-rated in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 0.35 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

The system has seen 8 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
68.7 out of 100 Grade C+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
26.4/45
D
Historical violation record including health-based and monitoring violations.
Lead & Copper
16/20
B
Lead at 1.3 ppb (90th percentile).
Contaminants
14.3/20
C
1 PFAS compound detected.
Compliance
8/10
B
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Purchased surface water.
Water Safety

Is Medina, OH water safe to drink?

Concerns Identified

Medina's drinking water has significant quality concerns based on EPA testing data. With a grade of C+ (68.7/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 6 water systems serve approximately 73,148 residents using surface water (rivers, lakes, or reservoirs).

25
Active Violations
1.3 ppb
Lead (90th %ile)
1 compound
PFAS Detected
1 event
Disaster History

Recent water quality updates for Medina

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Medina's water quality assessment. Grade: C+ (68.7/100).

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Violation
2 drinking water violations recorded

Contaminants: Consumer Confidence Rule.

Disaster
HURRICANE KATRINA EVACUATION

Federal disaster declaration (FEMA DR-3250). Hurricane event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Medina's water supply.

Lead Within Limits
Detected: 1.3 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Copper Exceeds Limit
Detected: 110.00 mg/L Limit: 1.3 mg/L (EPA Action Level)

Exceeds EPA action level. Copper can leach from household plumbing — flush taps for 30 seconds before drinking.

PFAS (1 compound) Elevated
Detected: Highest: PFBA at 0.0155 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Medina's water system has 138 total violations on record, including 15 health-based violations. 25 remain unresolved. 8 violations were issued in the last 5 years.

OtherMRMCLTT
Most recent violations:
Jan 2024 Consumer Confidence Rule Open
Oct 2023 Consumer Confidence Rule Open
Dec 2022 Consumer Confidence Rule Open
Dec 2022 Consumer Confidence Rule Open
Sep 2022 Consumer Confidence Rule Open

Flood & environmental risk

Medina County has experienced 1 federally declared disaster since 2005. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Little Killbuck Creek Near Lodi.

HURRICANE KATRINA EVACUATION
Hurricane FEMA DR-3250

Where does Medina's water come from?

Medina's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 6 water systems serving approximately 73,148 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Little Killbuck Creek Near Lodi (river).

What Medina residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Medina's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
1.3 ppb
EPA Action Level: 15 ppb · 9% of limit
Safe Level
Copper (90th percentile)
Inorganic
Over Limit
110.00 mg/L
EPA Action Level: 1.3 mg/L · +20% over limit
Exceeds Limit
PFBA
PFAS / Forever Chemical
Near MCL
0.0155 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
25.4 µg/L
EPA MCL: 60 µg/L · 42% of limit
Within LimitUCMR 4 DataHAA6Br: 11.4 µg/LHAA9: 36.0 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.35 µg/L
CA MCL (no federal MCL): 10 µg/L · 3% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
240.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 16% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
11.7 µg/L
EPA Secondary MCL: 50 µg/L · 23% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Detected
0.34 µg/L
EPA Short-term HA: 21 µg/L · 2% of limit
DetectedUCMR 3 Data
Chlorate
Disinfection Byproduct
Detected
58.8 µg/L
EPA Lifetime HA: 210 µg/L · 28% of limit
DetectedUCMR 3 Data
Molybdenum
Inorganic
Detected
1.90 µg/L
EPA Lifetime HA: 40 µg/L · 5% of limit
DetectedUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

138
Total violations
15
Health-based
25
Active / unresolved
Jan 2024
Most recent violation
Compliance Record

Violations & advisories

138 Total
25 Active
15 Health-based
113 Resolved
Violations by category
Volatile Organic Chemicals
42
Inorganic Chemicals
18
Total Coliform Rule
17
Consumer Confidence Rule
14
Synthetic Organic Chemicals
12
Jan 2024 Active
Consumer Confidence Rule
Other Violation 0
Oct 2023 Active
Consumer Confidence Rule
Other Violation 0
Dec 2022 Active
Consumer Confidence Rule
Other Violation 0
Dec 2022 Active
Consumer Confidence Rule
Other Violation 0
Sep 2022 Active
Consumer Confidence Rule
Other Violation 0
Jul 2022 Active
Consumer Confidence Rule
Other Violation 0
Jul 2021 Active
Consumer Confidence Rule
Other Violation 0
Jan 2021 Active
Consumer Confidence Rule
Other Violation 0
May 2020 Active
Public Notice
Other Violation 0
Jan 2020 Active
Consumer Confidence Rule
Other Violation 0
Nov 2018 Active
Consumer Confidence Rule
Other Violation 0
Nov 2018 Active
Consumer Confidence Rule
Other Violation 0
Jul 2012 Active
Consumer Confidence Rule
Other Violation 0
Dec 2010 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Dec 2009 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jul 2003 Active
Consumer Confidence Rule
Other Violation 0
Jul 2003 Active
Consumer Confidence Rule
Other Violation 0
Jan 1997 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jan 1995 Active
Lead and Copper Rule
Treatment Technique
Health-Based Health 0
Jan 1994 Active
Lead and Copper Rule
Treatment Technique
Health-Based Health 0
Showing 20 of 138 violations
Industrial pollution

Top industrial polluters within 10 miles of Medina

Industrial polluters nearby

Reported releases to surface water by facilities near Medina, ranked by pounds discharged annually.

Total reported releases to surface water: 6 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
ADVANCE BRONZE SEVILLE LLC
Primary Metals · NA
SEVILLE, OH44273
Copper58.7 mi
HUBBELL POWER SYSTEMS INC.
Computers and Electronic Products · HUBBELL INC
WADSWORTH, OH44281
Zinc compounds18.8 mi
COLUMBIA CHEMICAL CORP
Chemicals · NA
BRUNSWICK, OH44212
8.7 mi
SAFETY-KLEEN SYSTEMS BRUNSWICK (BRU)
Hazardous Waste · CLEAN HARBORS INC
BRUNSWICK, OH44212
8.4 mi
FBC CHEMICAL MEDINA
Chemical Wholesalers · FBC CHEMICAL CORP
MEDINA, OH44256
1.1 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Environmental Risk

Flood & disaster history

1
Declared disasters
Sep 2005
Most recent
Hurricane
Most common type

Medina County has experienced 1 federally declared disaster since 2005. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Sep 2005
HURRICANE KATRINA EVACUATION
Hurricane FEMA #3250

Recommended water filters

Based on contaminants detected in Medina's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected
🔧
For Copper
Reverse Osmosis or KDF Filter
Copper exceeds the EPA action level of 1.3 mg/L

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.3 15 ppb Inorganic Safe
Copper (90th percentile) 110.00 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.015 HI µg/L PFAS Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 5.5 ppb from 1992 (8.3 ppb) to 2025 (2.8 ppb).

Copper level trend (90th percentile)

EPA action level: 1.3 mg/L
Copper has increased by 66.500 mg/L from 2004 (128.000 mg/L) to 2005 (194.500 mg/L).
Infrastructure

Water source & infrastructure

Primary Source
Purchased Surface Water
Operator
Local Government
Population Served
73,148
Water Systems
6
Source breakdown
Groundwater
3
Purchased Surface Water
2
Purchased Groundwater
1
Water Source

Where Medina's water comes from

Purchased Surface Water

Medina's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 73,148 people through 6 water systems.

Local Hydrology

Water bodies near Medina

Medina is located near 1 notable water body. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Little Killbuck Creek Near Lodi
river
Infrastructure

Water systems serving Medina

System Name PWSID Population Source
MEDINA CO/NORTHWEST PWS OH5201903 46,324 SWP
MEDINA CITY PWS OH5200514 25,956 SWP
MEDINA CO/SHARON-WADSWORTH PWS OH5202003 566 GWP
GRANGER LAKE CONDO 1 PWS OH5202112 131 GW
GRANGER LAKE CONDO 4 PWS OH5202212 108 GW
GRANGER LAKE CONDOS 2 AND 3 OH5202312 63 GW
Regional Comparison

How Medina compares

Full Ohio rankings →

Medina's score of 68.7/100 is above the average of 58/100 among major Ohio cities. It outscores 6 of 10 nearby cities.

Medina (this city)
68.7
Columbus
35.5
Cleveland
85.5
Cincinnati
36.8
Toledo
78
Kent
38.2
Ohio avg
58
City Profile

About Medina, OH

Economic Profile
$74,820
Median Income
$210,598
Median Home Value
$966/mo
Median Rent
4.8%
Unemployment
Community
40.2
Median Age
870
People / sq mi
35.6%
College Educated
69.3%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Medina, OH tap water safe to drink?

Medina's water quality earned a grade of C+ (68.7/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #424 out of 511 cities tested in Ohio.

What contaminants are in Medina's water?

Lead was measured at 1.3 ppb (90th percentile). 1 PFAS compound was detected. 138 violations are on record.

How is Medina's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Medina?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Medina's water come from?

Medina's water is sourced from Purchased surface water. The city has 6 water systems serving approximately 73,148 residents.

What health violations has Medina's water system had?

Medina has 15 health-based violations on record. The most recent violation was recorded in January 2024. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 25 violations remain unresolved.

How does Medina's water compare to other cities?

Medina ranks #424 out of 511 cities in Ohio (better than 17% of state cities) and #11027 out of 15744 cities nationally (30th percentile). The grade of C+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.