Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is Lafayette, CO Tap Water Safe to Drink?

Graded F — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do ↓

1 contaminant over a legal limit
0.0 ppb lead, 90th percentile · low
53 unresolved violations
32K people served by 9 water systems

PWSID CO0107473 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
F 42.6 / 100

#216 of 244Colorado cities
How we grade →

01The verdict: is Lafayette water safe?

Lafayette's drinking water has significant quality concerns based on EPA testing data. With a grade of F (42.6/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 9 water systems serve approximately 32,346 residents using surface water (rivers, lakes, or reservoirs).

The concern

Copper is over its legal limit

Measured at 1.98 mg/L against the EPA Action Level of 1.3 mg/L. The ledger below shows how far over — and which filter removes it.

See the measurement ↓
The good news

Lead is well under the limit

90th-percentile lead is 0.0 ppb — beneath the 15 ppb federal action level and under the 5 ppb watch threshold.

See the trend ↓
Keep watching

Chlorate is approaching its limit

Measured at 120.0 µg/L — 57% of the 210 µg/L limit. Within the rules, but with less headroom than you'd want.

See the ledger ↓

Lafayette's drinking water received a grade of F (42.6 out of 100), indicating failing water quality. The city's 9 water systems serve approximately 32,346 residents using surface water.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. PFAS testing under UCMR 5 found no detectable forever chemicals. The system has 461 violations on record, including 19 health-based violations. 53 remain unresolved.

Lafayette ranks #216 out of 244 cities in Colorado for water quality, placing it among the lowest-rated in the state. The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection. Hexavalent chromium (chromium-6) was detected at 0.05 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration. The system has seen 90 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

How the 42.6/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
0 / 45F
Lead & CopperLead at 0.0 ppb (90th percentile).
16 / 20B
ContaminantsNo PFAS compounds detected.
14.7 / 20C
ComplianceMonitoring and reporting compliance with EPA regulations.
8 / 10B
Source RiskWater source: Surface water.
4 / 5B

02What's in Lafayette's water

Every contaminant flagged in Lafayette, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

8 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%

Over Limit — EPA Action Level: 1.3 mg/L

Exceeds the EPA action level. Copper leaches from household plumbing — flush taps for 30 seconds before drinking, and consider a certified filter.
Exceeds Limit What to do →
Chlorate Disinfection Byproduct
120.0 µg/L 57% of limit
Strontium Inorganic
270.0 µg/L 18% of limit
Manganese Inorganic
2.2 µg/L 4% of limit
Molybdenum Inorganic
1.30 µg/L 3% of limit
38 contaminants tested under EPA SDWIS, LCR and UCMR programs · 8 detected Contaminants without a federal MCL are shown against the strictest state or advisory level named in each row.

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
Copper (90th percentile) 1.98 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Lafayette's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 461 violations on record, including 19 health-based violations. 53 remain unresolved.

1 of the last ten years was clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

4 health-based in 10 yrs 214 monitoring & paperwork 36 still unresolved
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Lafayette's water quality assessment. Grade: F (42.6/100).
Violation3 drinking water violations recordedContaminants: Public Notice, Surface Water Treatment Rule, Interim Enhanced Surface Water Treatment Rule.Open
Violation3 drinking water violations recordedContaminants: Revised Total Coliform Rule, Public Notice, Lead and Copper Rule.Open
Violation8 drinking water violations recordedContaminants: Revised Total Coliform Rule, Surface Water Treatment Rule, Chlorine.Open
DisasterSEVERE STORMS, TORNADOES, FLOODING, LANDSLIDES, AND MUDSLIDESFederal disaster declaration (FEMA DR-4229). Flood event — may have impacted local water infrastructure.
DisasterSEVERE STORMS, FLOODING, LANDSLIDES, AND MUDSLIDESFederal disaster declaration (FEMA DR-4145). Flood event — may have impacted local water infrastructure.
Lead, 90th percentileppb · lower is better
0255075100125EPA action level · 15 ppb1992 — 5 ppb1993 — 8 ppb1994 — 5 ppb1995 — 1 ppb1996 — 2 ppb1998 — 5 ppb1999 — 2 ppb2001 — 2 ppb2002 — 4 ppb2003 — 7 ppb2004 — 1 ppb2005 — 8 ppb2006 — 4 ppb2007 — 5.5 ppb2010 — 91 ppb2011 — 0 ppb2013 — 2 ppb2014 — 1.4 ppb2015 — 6.1 ppb2016 — 0 ppb2017 — 2 ppb2018 — 0.87 ppb2019 — 0.50 ppb2020 — 3 ppb2021 — 0 ppb2022 — 0 ppb2023 — 3 ppb2024 — 0 ppb2025 — 0 ppb50199219992006201520212025

Down 5 ppb since 1992. Latest reading: 0 ppb (2025) — 0% of the action level. Sampled at higher-risk homes (90th percentile).

Copper, 90th percentilemg/L

2.0mg/L(2020)

One sampling round on record — 152% of the 1.3mg/L EPA action level. Sampled at higher-risk homes (90th percentile).

04Where Lafayette's water comes from

Lafayette's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Source

Surface Water

Rivers, lakes, or reservoirs — more exposed to runoff, agriculture, and seasonal swings than groundwater.

Treatment

Local treatment

Multi-barrier treatment: coagulation, sedimentation, filtration, and disinfection to meet EPA standards.

Distribution

9 systems

9 water systems, operated under local government ownership.

Delivery

32,346 people

Residents served across Lafayette's service area.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards. These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge. The system is operated by local government ownership and serves approximately 32,346 people through 9 water systems.

System namePWSIDPopulationSource
LAFAYETTE CITY OF CO0107473 28,700 Surface Water
ARBORDALE ACRES MHP CO0107118 901 Purchased Surface Water
BOULDER RIDGE MHP CO0107153 897 Purchased Surface Water
SAN LAZARO MFCTD HOUSING COMMUNITY CO0107701 844 Surface Water
CHEYENNE MOUNTAIN ESTATES MHP CO0121176 472 Purchased Surface Water
SKYLARK MOBILE HOME COMMUNITY CO0107712 342 Purchased Surface Water
FORTUNE BRANCH VILLAGE MHP OR4105734 80 Groundwater
LARK MEADOWS WA CO0107489 75 Groundwater
MAPLE GROVE WD CO0107502 35 Groundwater

Water bodies near Lafayette

Big Dry Creek · river Left Hand Creek · river Boulder Creek · river

As a surface-water system, these water bodies may directly influence Lafayette's drinking water supply.

05Pressure on Lafayette's watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Industrial discharge

Present — monitored

5 facilities within 10 miles reported 0 lb released to surface water in the latest EPA Toxics Release Inventory. Proximity doesn't equal tap contamination — treatment and hydrology decide — but it's pressure on the watershed.

HOLCIM WCR INC BROOMFIELD READY MIX PLANT 0 lb · 4.6 mi
HUNTER DOUGLAS WINDOW FASHIONS INC 0 lb · 4.7 mi
DHARMACON INC 0 lb · 2.1 mi
+ 2 more facilities

Flood & storm history

Recurring — declared disasters

6 federal disaster declarations on record for Boulder County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

SEVERE STORMS, TORNADOES, FLOODING, LANDSLIDES, AND MUDSLIDES Jul 2015 · DR-4229
SEVERE STORMS, FLOODING, LANDSLIDES, AND MUDSLIDES Sep 2013 · DR-4145
SEVERE STORMS, FLOODING, LANDSLIDES, AND MUDSLIDES Sep 2013 · DR-3365

Superfund proximity

Multiple tracked sites nearby

2 National Priorities List sites within 10 miles. Proximity does not necessarily indicate tap-water contamination — the connection depends on hydrology and treatment.

Drought

D3 — extreme drought

Boulder County is in D3 (extreme drought) per the U.S. Drought Monitor (week of Jul 2026). Drought can raise disinfection-byproduct levels and taste/odor issues as utilities draw from lower reservoirs.

Current streak at D2+ severity23 wks
Weeks at D2+ in the last 5 years23 wks
Months in D2+ over the last 30 years17.5%

06How Lafayette compares

Scores for nearby Colorado cities on one line, with the average marked.

Fort Collins
46.8 · D
Lafayette (this city)
42.6 · F
Denver
39.6 · F
Aurora
38.1 · F
Lakewood
36.9 · F

dashed line = Colorado average (45/100)

Lafayette scores 42.6/100on par with the Colorado average of 45/100. It outscores 5 of 10 nearby cities. Full Colorado rankings →

Boulder water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Lafayette's water — not generic advice.

Because of copper

Filter drinking & cooking water

NSF-certified water filter. Copper exceeds the EPA action level of 1.3 mg/L

Compare tested filters →
Know your report

Read your utility's annual report

Every utility must publish a yearly Consumer Confidence Report with its own testing results. It pairs well with the independent data on this page.

How to read a CCR →
Stay informed

Watch for Lafayette alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Lafayette, CO tap water safe to drink?

Lafayette's water quality earned a grade of F (42.6/100). Significant issues have been found. A water filter is strongly recommended. The city ranks #216 out of 244 cities tested in Colorado.

What contaminants are in Lafayette's water?

Lead was measured at 0.0 ppb (90th percentile). No PFAS compounds were detected. 461 violations are on record.

How is Lafayette's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Lafayette?

Based on current data, basic filtration should suffice for additional peace of mind.

Where does Lafayette's water come from?

Lafayette's water is sourced from Surface water. The city has 9 water systems serving approximately 32,346 residents.

What health violations has Lafayette's water system had?

Lafayette has 19 health-based violations on record. The most recent violation was recorded in December 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 53 violations remain unresolved.

How does Lafayette's water compare to other cities?

Lafayette ranks #216 out of 244 cities in Colorado (better than 11% of state cities) and #14452 out of 15382 cities nationally (6th percentile). The grade of F reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Lafayette, CO: The City of Lafayette is a home rule municipality located in southeastern Boulder County, Colorado, United States. The city population was 30,411 at the 2020 United States census. Median household income $105,819 · median home value $606,081 · median age 38.7 · 67.9% homeowners · 63.1% college educated. Wikipedia → Service area: 1 ZIP code across Boulder.
Show ZIP codes 80026
Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.