WaterVerge

Is Franklin Furnace, OH Tap Water Safe to Drink?

Graded D — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

18K residents served 13 water systems PWSID: OH7300303
Overall Score
47.1 / 100
Violations
31 active
Last Updated
May 2026
Source
Groundwater
#488 of 511 in Ohio Top 87% nationally
Private
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
DGRADE
Water Quality Grade
47.1/100
waterverge.com
D 47.1/100

Franklin Furnace, OH — Water Quality Report

Franklin Furnace's drinking water received a grade of D (47.1 out of 100), indicating poor water quality. The city's 13 water systems serve approximately 17,749 residents using groundwater.

Lead levels were measured at 4.6 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 91 violations on record, including 8 health-based violations. 31 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Franklin Furnace's water

Franklin Furnace ranks #488 out of 511 cities in Ohio for water quality, placing it among the lowest-rated in the state.

Franklin Furnace relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 0.05 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

The system has seen 19 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
47.1 out of 100 Grade D
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
5.6/45
F
Historical violation record including health-based and monitoring violations.
Lead & Copper
14/20
C
Lead at 4.6 ppb (90th percentile).
Contaminants
17.5/20
B
1 PFAS compound detected.
Compliance
5/10
D
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Franklin Furnace, OH water safe to drink?

Concerns Identified

Franklin Furnace's drinking water has significant quality concerns based on EPA testing data. With a grade of D (47.1/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 13 water systems serve approximately 17,749 residents using groundwater (wells).

31
Active Violations
4.6 ppb
Lead (90th %ile)
1 compound
PFAS Detected
6 events
Disaster History

Recent water quality updates for Franklin Furnace

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Franklin Furnace's water quality assessment. Grade: D (47.1/100).

Violation
12 drinking water violations recorded

Contaminants: LEAD AND COPPER RULE REVISIONS, Consumer Confidence Rule.

Violation
1 drinking water violation recorded

Contaminants: Public Notice.

Violation
6 drinking water violations recorded

Contaminants: TTHM, Total Haloacetic Acids (HAA5).

Disaster
SEVERE STORMS, FLOODING, AND LANDSLIDES

Federal disaster declaration (FEMA DR-4424). Flood event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Franklin Furnace's water supply.

Lead Within Limits
Detected: 4.6 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Copper Exceeds Limit
Detected: 491.00 mg/L Limit: 1.3 mg/L (EPA Action Level)

Exceeds EPA action level. Copper can leach from household plumbing — flush taps for 30 seconds before drinking.

PFAS (1 compound) Elevated
Detected: Highest: PFHxS at 0.0042 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Franklin Furnace's water system has 91 total violations on record, including 8 health-based violations. 31 remain unresolved. 19 violations were issued in the last 5 years.

RPTOtherMRMCL
Most recent violations:
Jul 2025 LEAD AND COPPER RULE REVISIONS Open
Jul 2025 LEAD AND COPPER RULE REVISIONS Open
Jul 2025 LEAD AND COPPER RULE REVISIONS Open
Jul 2025 LEAD AND COPPER RULE REVISIONS Open
Jul 2025 LEAD AND COPPER RULE REVISIONS Open

Flood & environmental risk

Scioto County has experienced 6 federally declared disasters since 1968. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Ohio River, Tygarts Creek.

SEVERE STORMS, FLOODING, AND LANDSLIDES
Flood FEMA DR-4424
SEVERE STORMS, LANDSLIDES, AND MUDSLIDES
Flood FEMA DR-4360
HURRICANE KATRINA EVACUATION
Hurricane FEMA DR-3250

Where does Franklin Furnace's water come from?

Franklin Furnace's drinking water comes from groundwater (wells), supplied by 13 water systems serving approximately 17,749 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Ohio River (river), Tygarts Creek (river).

What Franklin Furnace residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Franklin Furnace's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Flush your taps

Run cold water for 30 seconds before drinking, especially in the morning. Lead and copper leach from household plumbing when water sits in pipes.

Monitor alerts during storms

Franklin Furnace's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
4.6 ppb
EPA Action Level: 15 ppb · 31% of limit
Safe Level
Copper (90th percentile)
Inorganic
Over Limit
491.00 mg/L
EPA Action Level: 1.3 mg/L · +20% over limit
Exceeds Limit
PFHxS
PFAS / Forever Chemical
Near MCL
0.0042 µg/L
EPA MCL: 0.004 µg/L · +5% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
6.1 µg/L
EPA MCL: 60 µg/L · 10% of limit
Within LimitUCMR 4 DataHAA6Br: 6.5 µg/LHAA9: 11.0 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.05 µg/L
CA MCL (no federal MCL): 10 µg/L · 1% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
183.8 µg/L
EPA Health Ref Level: 1,500 µg/L · 12% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
3.1 µg/L
EPA Secondary MCL: 50 µg/L · 6% of limit
DetectedUCMR 4 Data
Molybdenum
Inorganic
Detected
1.76 µg/L
EPA Lifetime HA: 40 µg/L · 4% of limit
DetectedUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

91
Total violations
8
Health-based
31
Active / unresolved
Jul 2025
Most recent violation
Compliance Record

Violations & advisories

91 Total
31 Active
8 Health-based
60 Resolved
12 SNC
Violations by category
Total Coliform Rule
25
Volatile Organic Chemicals
21
Consumer Confidence Rule
14
Stage 2 Disinfectants and Disinfection Byproducts Rule
14
Lead and Copper Rule Revisions
11
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Jul 2025 Active
Consumer Confidence Rule
Other Violation 0
Nov 2021 Active
Public Notice
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Feb 2020 Active
Consumer Confidence Rule
Other Violation 0
Showing 20 of 91 violations
Industrial pollution

Top industrial polluters within 10 miles of Franklin Furnace

Industrial polluters nearby

Reported releases to surface water by facilities near Franklin Furnace, ranked by pounds discharged annually.

Total reported releases to surface water: 8,382 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
ALTIVIA PETROCHEMICALS, LLC
Chemicals · ALTIVIA CORP
HAVERHILL, OH45636
Formic acid8,3733.1 mi
HARBISONWALKER INTERNATIONAL INC
Nonmetallic Mineral Product · PLATINUM EQUITY ADVISORS LLC
SOUTH SHORE, KY41175
Chromium and Chromium Compounds(except for chromite ore mined in the Transvaal Region)57.0 mi
AMERICAS STYRENICS LLC - HANGING ROCK
Chemicals · AMERICAS STYRENICS LLC
IRONTON, OH45638
Zinc compounds35.0 mi
OSCO INDUSTRIES INC NEW BOSTON DIV
Primary Metals · OSCO INDUSTRIES INC
NEW BOSTON, OH45662
Lead compounds19.7 mi
HAVERHILL COKE CO LLC
Petroleum · SUNCOKE ENERGY INC
FRANKLIN FURNACE, OH45629
2.2 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Site context

Superfund sites within 10 miles of Franklin Furnace

Superfund sites nearby

Federally tracked hazardous-waste sites on the EPA National Priorities List. Proximity does not necessarily indicate tap-water contamination — the connection depends on hydrology and treatment.

Source: EPA Superfund National Priorities List

Environmental Risk

Drought conditions

D1 — moderate drought

Scioto County is currently in D1 (moderate drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

12.5%
Months in D2+ (last 30y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

6
Declared disasters
Apr 2019
Most recent
Flood
Most common type

Scioto County has experienced 6 federally declared disasters since 1968. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Apr 2019
SEVERE STORMS, FLOODING, AND LANDSLIDES
Flood FEMA #4424
Apr 2018
SEVERE STORMS, LANDSLIDES, AND MUDSLIDES
Flood FEMA #4360
Sep 2005
HURRICANE KATRINA EVACUATION
Hurricane FEMA #3250
Jun 1996
FLOODING
Flood FEMA #1122
Jan 1996
SEVERE STORMS AND FLOODING
Flood FEMA #1097
Jun 1968
HEAVY RAINS & FLOODING
Flood FEMA #243

Recommended water filters

Based on contaminants detected in Franklin Furnace's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected
🔧
For Copper
Reverse Osmosis or KDF Filter
Copper exceeds the EPA action level of 1.3 mg/L

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 4.6 15 ppb Inorganic Safe
Copper (90th percentile) 491.00 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS 0.004 HI µg/L PFAS Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 4.3 ppb from 1992 (4.3 ppb) to 2025 (0.0 ppb).

Copper level (90th percentile)

Latest reading: 491.000 mg/L (2004)

EPA action level: 1.3 mg/L

Contaminant Rankings

See how Franklin Furnace compares by contaminant

Explore where Franklin Furnace ranks among all Ohio cities for specific contaminants.

Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Private
Population Served
17,749
Water Systems
13
Source breakdown
Purchased Surface Water
10
Groundwater
2
Purchased Groundwater
1
Water Source

Where Franklin Furnace's water comes from

Groundwater

Franklin Furnace's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by private ownership and serves approximately 17,749 people through 13 water systems.

Local Hydrology

Water bodies near Franklin Furnace

Franklin Furnace is located near 2 notable water bodies. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Ohio River
river
Tygarts Creek
river
Infrastructure

Water systems serving Franklin Furnace

System Name PWSID Population Source
SCIOTO WATER INC.-ROSE HILL OH7300303 8,861 GW
SCIOTO WATER INC.-SUGAR CAMP OH7300903 6,458 GW
SCIOTO WATER INC. - POND RUN OH7301303 845 SWP
SCIOTO WATER INC.-SR125 OH7301203 537 SWP
SCIOTO WATER INC.-CAREYS RUN OH7301703 352 SWP
SCIOTO WATER INC - STONY RUN OH7300803 178 SWP
SCIOTO WATER, INC.-DAVIS CAMP OH7302503 134 GWP
SCIOTO WATER INC.-SLAB RUN OH7301603 115 SWP
SCIOTO WATER INC. - ZEIGLER LANE OH7301503 76 SWP
SCIOTO WATER INC.-HYGEAN RUN OH7301903 64 SWP
SCIOTO WATER INC.-NACE'S RUN OH7302103 59 SWP
SCIOTO WATER INC.-OAKWOOD OH7302203 36 SWP
SCIOTO WATER INC.- SHEILA BLVD OH7302403 34 SWP
Regional Comparison

How Franklin Furnace compares

Full Ohio rankings →

Franklin Furnace's score of 47.1/100 is below the average of 58/100 among major Ohio cities. It outscores 4 of 10 nearby cities. 6 of 10 nearby cities score higher.

Franklin Furnace (this city)
47.1
Columbus
35.5
Cleveland
85.5
Cincinnati
36.8
Toledo
78
Kent
38.2
Ohio avg
58
City Profile

About Franklin Furnace, OH

Wikipedia →

Franklin Furnace is a census-designated place (CDP) in Scioto County, Ohio, United States, along the Ohio River. The population was 1,525 at the 2020 census.

Economic Profile
$49,200
Median Income
$118,309
Median Home Value
$660/mo
Median Rent
2.5%
Unemployment
Community
38.9
Median Age
311
People / sq mi
15%
College Educated
83.1%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Franklin Furnace, OH tap water safe to drink?

Franklin Furnace's water quality earned a grade of D (47.1/100). Significant issues have been found. A water filter is strongly recommended. The city ranks #488 out of 511 cities tested in Ohio.

What contaminants are in Franklin Furnace's water?

Lead was measured at 4.6 ppb (90th percentile). 1 PFAS compound was detected. 91 violations are on record.

How is Franklin Furnace's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Franklin Furnace?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Franklin Furnace's water come from?

Franklin Furnace's water is sourced from Groundwater. The city has 13 water systems serving approximately 17,749 residents.

What health violations has Franklin Furnace's water system had?

Franklin Furnace has 8 health-based violations on record. The most recent violation was recorded in July 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 31 violations remain unresolved.

Is Franklin Furnace's groundwater at risk of contamination?

Franklin Furnace uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 91 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Franklin Furnace's water compare to other cities?

Franklin Furnace ranks #488 out of 511 cities in Ohio (better than 5% of state cities) and #13662 out of 15744 cities nationally (13th percentile). The grade of D reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.