Is Dania Beach, FL Tap Water Safe to Drink?

Graded D — but PFOS was detected above EPA limits. Here's what's in the water and how to remove it. What to do ↓

1 contaminant over a legal limit
1.1 ppb lead, 90th percentile · low
12 unresolved violations
30K people served by 1 water system

PWSID FL4060253 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
D 45.8 / 100

#296 of 366Florida cities
How we grade →

01The verdict: is Dania Beach water safe?

Dania Beach's drinking water has significant quality concerns based on EPA testing data. With a grade of D (45.8/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 30,000 residents using groundwater (wells).

The concern

PFOS is over its legal limit

Measured at 0.0139 µg/L against the EPA MCL of 0.004 µg/L. The ledger below shows how far over — and which filter removes it.

See the measurement ↓
The good news

Lead is well under the limit

90th-percentile lead is 1.1 ppb — beneath the 15 ppb federal action level and under the 5 ppb watch threshold.

See the trend ↓
Keep watching

35 violations in the last five years

Recent compliance history is the best predictor of future problems — the year-by-year record is below.

See the record ↓

Dania Beach's drinking water received a grade of D (45.8 out of 100), indicating poor water quality. The city's 1 water system serves approximately 30,000 residents using groundwater.

Lead levels were measured at 1.1 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 8 PFAS compounds, with levels exceeding EPA maximum contaminant levels in the water supply. The system has 58 violations on record, including 9 health-based violations. 12 remain unresolved.

Dania Beach ranks #296 out of 366 cities in Florida for water quality, placing it among the lowest-rated in the state. Dania Beach relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff. Of particular concern: PFAS "forever chemical" levels exceed the 2024 EPA maximum contaminant levels. These synthetic compounds don't break down naturally and require specialized filtration such as reverse osmosis or granular activated carbon. Hexavalent chromium (chromium-6) was detected at 0.13 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration. The system has seen 35 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

How the 45.8/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
5.8 / 45F
Lead & CopperLead at 1.1 ppb (90th percentile).
20 / 20A
Contaminants8 PFAS compounds detected.
10 / 20D
ComplianceMonitoring and reporting compliance with EPA regulations.
5 / 10D
Source RiskWater source: Groundwater.
5 / 5A

02What's in Dania Beach's water

Every contaminant flagged in Dania Beach, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

7 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%

Over MCL — EPA MCL: 0.004 µg/L

PFAS "forever chemicals" exceed the 2024 EPA maximum contaminant levels, which utilities must meet by 2029. These compounds don't break down in the body or the environment. Reverse osmosis (NSF/ANSI 58) or certified granular activated carbon (NSF/ANSI 53) removes them at the tap.
Exceeds MCL What to do →
Strontium Inorganic
203.0 µg/L 14% of limit
Vanadium Inorganic
0.89 µg/L 4% of limit
Manganese Inorganic
0.8 µg/L 2% of limit
36 contaminants tested under EPA SDWIS, LCR and UCMR programs · 14 detected · 2 PFAS over EPA MCL · PFAS hazard index 4.92 (above the 1.0 threshold) Contaminants without a federal MCL are shown against the strictest state or advisory level named in each row.

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.1 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.005 HI µg/L PFAS Detected
PFBS 0.004 HI µg/L PFAS Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA 0.003 HI µg/L PFAS Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA 0.006 HI µg/L PFAS Detected
PFHxS 0.005 HI µg/L PFAS Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA 0.006 0.004 µg/L PFAS Over MCL
PFOS 0.014 0.004 µg/L PFAS Over MCL
PFPeA 0.009 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Dania Beach's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 58 violations on record, including 9 health-based violations. 12 remain unresolved.

4 of the last ten years were clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

1 health-based in 10 yrs 39 monitoring & paperwork 6 still unresolved
PFAS8 PFAS "forever chemical" compounds detectedPFAS levels exceed EPA maximum contaminant levels. Reverse osmosis or activated carbon filtration recommended.
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Dania Beach's water quality assessment. Grade: D (45.8/100).
Violation1 drinking water violation recordedContaminants: Revised Total Coliform Rule.Resolved
Violation1 drinking water violation recordedContaminants: Consumer Confidence Rule.Open
Violation2 drinking water violations recordedContaminants: E. COLI, Revised Total Coliform Rule.Resolved
DisasterHURRICANE MILTONFederal disaster declaration (FEMA DR-4834). Hurricane event — may have impacted local water infrastructure.
Lead, 90th percentileppb · lower is better
020406080100EPA action level · 15 ppb1992 — 78 ppb1993 — 10 ppb1994 — 5 ppb1995 — 6 ppb1996 — 1 ppb1997 — 3 ppb2000 — 0 ppb2003 — 0 ppb2006 — 1.5 ppb2009 — 2 ppb2011 — 7.8 ppb2012 — 4 ppb2013 — 1.8 ppb2014 — 1.7 ppb2015 — 2.1 ppb2017 — 7.2 ppb2018 — 1.4 ppb2019 — 1.2 ppb2020 — 1.3 ppb2023 — 1.1 ppb781.1199219962006201320182023

Down 77 ppb since 1992. Latest reading: 1.1 ppb (2023) — 7% of the action level. Sampled at higher-risk homes (90th percentile).

04Where Dania Beach's water comes from

Dania Beach's drinking water is drawn from underground aquifers through wells.

Source

Groundwater

Underground aquifers reached by wells — naturally filtered, but can carry minerals like arsenic and nitrate.

Treatment

Local treatment

Groundwater generally needs less treatment — typically disinfection and, where needed, mineral removal.

Distribution

1 system

1 water system, operated under local government ownership.

Delivery

30,000 people

Residents served across Dania Beach's service area.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals. Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds. The system is operated by local government ownership and serves approximately 30,000 people through 1 water system.

System namePWSIDPopulationSource
DANIA BEACH, CITY OF FL4060253 30,000 Groundwater

05Pressure on Dania Beach's watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Industrial discharge

Present — monitored

5 facilities within 10 miles reported 7 lb released to surface water in the latest EPA Toxics Release Inventory. Proximity doesn't equal tap contamination — treatment and hydrology decide — but it's pressure on the watershed.

GLOBAL PORT EVERGLADES EAST TERMINAL — xylene (mixed isomers) 4 lb · 3.2 mi
FPL-LAUDERDALE POWER PLANT — ammonia 2 lb · 2.4 mi
FPL PORT EVERGLADES ENERGY CENTER — ammonia 1 lb · 3.2 mi
+ 2 more facilities

Flood & storm history

Recurring — declared disasters

10 federal disaster declarations on record for Broward County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

HURRICANE MILTON Oct 2024 · DR-4834
HURRICANE MILTON Oct 2024 · DR-3622
SEVERE STORMS, TORNADOES, AND FLOODING Apr 2023 · DR-4709

Superfund proximity

Multiple tracked sites nearby

5 National Priorities List sites within 10 miles. Proximity does not necessarily indicate tap-water contamination — the connection depends on hydrology and treatment.

Drought

D3 — extreme drought

Broward County is in D3 (extreme drought) per the U.S. Drought Monitor (week of Jul 2026). Drought can raise disinfection-byproduct levels and taste/odor issues as utilities draw from lower reservoirs.

Current streak at D2+ severity23 wks
Weeks at D2+ in the last 5 years23 wks
Months in D2+ over the last 30 years20.5%

06How Dania Beach compares

Scores for nearby Florida cities on one line, with the average marked.

West Palm Beach
59.2 · C-
Dania Beach (this city)
45.8 · D
Jacksonville
39.7 · F
Orlando
36.8 · F
Miami
35 · F
Tampa
34.4 · F

dashed line = Florida average (49/100)

Dania Beach scores 45.8/100on par with the Florida average of 49/100. It outscores 6 of 10 nearby cities. Full Florida rankings →

Broward water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Dania Beach's water — not generic advice.

Because of pfas

Filter drinking & cooking water

Reverse osmosis system. PFAS compounds exceed EPA maximum contaminant levels

Compare tested filters →
Know your report

Read your utility's annual report

Every utility must publish a yearly Consumer Confidence Report with its own testing results. It pairs well with the independent data on this page.

How to read a CCR →
Stay informed

Watch for Dania Beach alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Dania Beach, FL tap water safe to drink?

Dania Beach's water quality earned a grade of D (45.8/100). Significant issues have been found. A water filter is strongly recommended. The city ranks #296 out of 366 cities tested in Florida.

What contaminants are in Dania Beach's water?

Lead was measured at 1.1 ppb (90th percentile). 8 PFAS compounds were detected. 58 violations are on record.

How is Dania Beach's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Dania Beach?

PFAS compounds exceed EPA limits — a reverse osmosis or activated carbon filter is recommended.

Where does Dania Beach's water come from?

Dania Beach's water is sourced from Groundwater. The city has 1 water system serving approximately 30,000 residents.

What health violations has Dania Beach's water system had?

Dania Beach has 9 health-based violations on record. The most recent violation was recorded in August 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 12 violations remain unresolved.

Is Dania Beach's groundwater at risk of contamination?

Dania Beach uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 58 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

Why does Dania Beach have so many PFAS compounds in its water?

8 different PFAS "forever chemical" compounds were detected in Dania Beach's water supply during UCMR 5 testing. PFAS contamination often originates from proximity to military installations (AFFF firefighting foam), airports, industrial manufacturing sites, or wastewater treatment facilities. Some levels exceed the 2024 EPA maximum contaminant levels — a reverse osmosis or NSF-certified activated carbon filter is strongly recommended.

How does Dania Beach's water compare to other cities?

Dania Beach ranks #296 out of 366 cities in Florida (better than 19% of state cities) and #13815 out of 15382 cities nationally (10th percentile). The grade of D reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Dania Beach, FL: Dania Beach is a city in Broward County, Florida, United States. It is part of the Miami metropolitan area. As of the 2020 census, the city's population was 31,723. Median household income $46,330 · median home value $263,151 · median age 42 · 47.8% homeowners · 33.2% college educated. Wikipedia → Service area: 2 ZIP codes across Broward.
Show ZIP codes 3300433312
Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.