Skip to main content
WaterVerge

Water quality report · updated Jul 2026

Is Anson, ME Tap Water Safe to Drink?

Graded B — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do ↓

1 contaminant over a legal limit
4.3 ppb lead, 90th percentile · low
8 unresolved violations
6K people served by 1 water system

PWSID ME0090930 · high data confidence · local government utility

Reviewed by WaterVerge Editorial Team · Last updated July 2026
B 77.5 / 100

#111 of 156Maine cities
How we grade →

01The verdict: is Anson water safe?

Anson's drinking water has significant quality concerns based on EPA testing data. With a grade of B (77.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 5,568 residents using surface water (rivers, lakes, or reservoirs).

The concern

Copper is over its legal limit

Measured at 2.08 mg/L against the EPA Action Level of 1.3 mg/L. The ledger below shows how far over — and which filter removes it.

See the measurement ↓
The good news

Lead is well under the limit

90th-percentile lead is 4.3 ppb — beneath the 15 ppb federal action level and under the 5 ppb watch threshold.

See the trend ↓
Keep watching

8 violations in the last five years

Recent compliance history is the best predictor of future problems — the year-by-year record is below.

See the record ↓

Anson's drinking water received a grade of B (77.5 out of 100), indicating good water quality. The city's 1 water system serves approximately 5,568 residents using surface water.

Lead levels were measured at 4.3 ppb (90th percentile), well within EPA limits. PFAS testing under UCMR 5 found no detectable forever chemicals. The system has 51 violations on record, including 34 health-based violations. 8 remain unresolved.

Anson ranks #111 out of 156 cities in Maine for water quality, placing it below average in the state. The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection. The system has seen 8 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

How the 77.5/100 breaks down Methodology →
ViolationsHistorical violation record including health-based and monitoring violations.
31.5 / 45C
Lead & CopperLead at 4.3 ppb (90th percentile).
14 / 20C
ContaminantsNo PFAS compounds detected.
20 / 20A
ComplianceMonitoring and reporting compliance with EPA regulations.
8 / 10B
Source RiskWater source: Surface water.
4 / 5B

02What's in Anson's water

Every contaminant flagged in Anson, on one shared scale: distance to its own legal limit. The red line is the limit — anything past it is out of compliance, and the closer a bar gets, the less headroom the system has.

2 detections · sorted by % of legal limit
Over the limit Elevated — watch Within limits
0 50% LEGAL LIMIT 150%

Over Limit — EPA Action Level: 1.3 mg/L

Exceeds the EPA action level. Copper leaches from household plumbing — flush taps for 30 seconds before drinking, and consider a certified filter.
Exceeds Limit What to do →
32 contaminants tested under EPA SDWIS, LCR and UCMR programs · 2 detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 4.3 15 ppb Inorganic Safe
Copper (90th percentile) 2.08 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

03Anson's ten-year track record

Each box is one year. A green check means no EPA violations; a numbered badge counts that year's violations — red if any were health-based, amber if they were monitoring or paperwork issues. The system has 51 violations on record, including 34 health-based violations. 8 remain unresolved.

4 of the last ten years were clean. The numbered years had EPA violations — red when any were health-based, amber when they were paperwork or missed-testing issues.

13 monitoring & paperwork 6 still unresolved
UpdateWater quality data updatedLatest EPA compliance and testing data incorporated into Anson's water quality assessment. Grade: B (77.5/100).
Violation1 drinking water violation recordedContaminants: Lead and Copper Rule.Open
DisasterHURRICANE LEEFederal disaster declaration (FEMA DR-3598). Hurricane event — may have impacted local water infrastructure.
DisasterSEVERE STORM AND FLOODINGFederal disaster declaration (FEMA DR-4719). Flood event — may have impacted local water infrastructure.
Violation1 drinking water violation recordedContaminants: Consumer Confidence Rule.Open
Violation1 drinking water violation recordedContaminants: Public Notice.Open
Lead, 90th percentileppb · lower is better
05101520EPA action level · 15 ppb1992 — 10 ppb1996 — 12 ppb1997 — 13 ppb1998 — 13 ppb1999 — 6 ppb2002 — 8 ppb2005 — 10 ppb2009 — 6 ppb2013 — 4.7 ppb2015 — 3.4 ppb2016 — 3.4 ppb2018 — 4.9 ppb2021 — 2.2 ppb2024 — 4.3 ppb104.3199219982005201520212024

Down 5.7 ppb since 1992. Latest reading: 4.3 ppb (2024) — 29% of the action level. Sampled at higher-risk homes (90th percentile).

Copper, 90th percentilemg/L

2.1mg/L(1992)

One sampling round on record — 160% of the 1.3mg/L EPA action level. Sampled at higher-risk homes (90th percentile).

04Where Anson's water comes from

Anson's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Source

Surface Water

Rivers, lakes, or reservoirs — more exposed to runoff, agriculture, and seasonal swings than groundwater.

Treatment

Local treatment

Multi-barrier treatment: coagulation, sedimentation, filtration, and disinfection to meet EPA standards.

Distribution

1 system

1 water system, operated under local government ownership.

Delivery

5,568 people

Residents served across Anson's service area.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards. These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge. The system is operated by local government ownership and serves approximately 5,568 people through 1 water system.

System namePWSIDPopulationSource
ANSON AND MADISON WATER DISTRICT ME0090930 5,568 Surface Water

Water bodies near Anson

Cobbosseecontee Stream At Gardiner, Maine · river Kennebec River At Gardiner, Maine · stream

As a surface-water system, these water bodies may directly influence Anson's drinking water supply.

05Pressure on Anson's watershed

Outside forces that shape what reaches the treatment plant. None of these is a verdict on the tap by itself — but each adds pressure worth knowing about.

Flood & storm history

Recurring — declared disasters

9 federal disaster declarations on record for Sagadahoc County. Flooding and severe storms can overwhelm treatment plants, cause sewage overflows, and push runoff into supplies.

HURRICANE LEE Sep 2023 · DR-3598
SEVERE STORM AND FLOODING Jul 2023 · DR-4719
HURRICANE KATRINA EVACUATION Sep 2005 · DR-3256

06How Anson compares

Scores for nearby Maine cities on one line, with the average marked.

Cumberland
93.8 · A
Portland
93.2 · A
Falmouth
92.8 · A
Anson (this city)
77.5 · B
Raymond
55.9 · C-

dashed line = Maine average (85/100)

Anson scores 77.5/100below the Maine average of 85/100. It outscores 3 of 10 nearby cities. Full Maine rankings →

Somerset water quality rankings
Compare all cities in the county — grades, violations, and contaminant data side by side.

07What to do at home

Steps matched to what testing actually found in Anson's water — not generic advice.

Because of copper

Filter drinking & cooking water

NSF-certified water filter. Copper exceeds the EPA action level of 1.3 mg/L

Compare tested filters →
Because lead was detected

Flush taps & check your service line

Lead leaches from pipes as water sits. Run cold water 30 seconds before drinking (especially mornings), and ask the utility whether your address still has a lead service line.

Lead risks explained →
Stay informed

Watch for Anson alerts

This area has a history of flood declarations — after severe weather, watch for boil-water advisories from the utility, and check the live alerts on this page.

All water alerts →

Frequently asked questions

Is Anson, ME tap water safe to drink?

Anson's water quality earned a grade of B (77.5/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #111 out of 156 cities tested in Maine.

What contaminants are in Anson's water?

Lead was measured at 4.3 ppb (90th percentile). No PFAS compounds were detected. 51 violations are on record.

How is Anson's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Anson?

Based on current data, basic filtration should suffice for additional peace of mind.

Where does Anson's water come from?

Anson's water is sourced from Surface water. The city has 1 water system serving approximately 5,568 residents.

What health violations has Anson's water system had?

Anson has 34 health-based violations on record. The most recent violation was recorded in December 2024. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 8 violations remain unresolved.

How does Anson's water compare to other cities?

Anson ranks #111 out of 156 cities in Maine (better than 29% of state cities) and #8867 out of 15382 cities nationally (42th percentile). The grade of B reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.

Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail
About Anson, ME: Richmond is a town in Sagadahoc County, Maine, United States. The population was 3,522 at the 2020 census. The town contains the census-designated place of the same name. It is part of the Portland-South Portland-Biddeford metropolitan area, situated at the head of Merrymeeting Bay. Median household income $48,712 · median home value $114,083 · median age 43.3 · 76.1% homeowners · 12.5% college educated. Wikipedia → Service area: 2 ZIP codes across Somerset.
Show ZIP codes 0491104958
Sources: EPA SDWIS & ECHO · UCMR 3–5 · Lead & Copper Rule samples · EPA TRI · U.S. Drought Monitor · FEMA declarations. Data last updated Jul 2026. Analysis by the WaterVerge Editorial Team · methodology.