WaterVerge

Is Prior Lake, MN Tap Water Safe to Drink?

Graded B+ — but Chlorate was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

51K residents served 3 water systems PWSID: MN1700007
Overall Score
81.5 / 100
Violations
6 active
Last Updated
May 2026
Source
Groundwater
#405 of 466 in Minnesota Top 47% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
B+GRADE
Water Quality Grade
81.5/100
waterverge.com
B+ 81.5/100

Prior Lake, MN — Water Quality Report

Prior Lake's drinking water received a grade of B+ (81.5 out of 100), indicating good water quality. The city's 3 water systems serve approximately 50,541 residents using groundwater.

Lead levels were measured at 0.7 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 83 violations on record, including 1 health-based violation. 6 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Prior Lake's water

Prior Lake ranks #405 out of 466 cities in Minnesota for water quality, placing it among the lowest-rated in the state.

Prior Lake relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Quality Breakdown

Water quality score

See methodology →
81.5 out of 100 Grade B+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
33.2/45
C
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.7 ppb (90th percentile).
Contaminants
15.3/20
B
1 PFAS compound detected.
Compliance
8/10
B
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Prior Lake, MN water safe to drink?

Concerns Identified

Prior Lake's drinking water has significant quality concerns based on EPA testing data. With a grade of B+ (81.5/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 3 water systems serve approximately 50,541 residents using groundwater (wells).

6
Active Violations
0.7 ppb
Lead (90th %ile)
1 compound
PFAS Detected
10 events
Disaster History

Recent water quality updates for Prior Lake

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Prior Lake's water quality assessment. Grade: B+ (81.5/100).

Disaster
SEVERE WINTER STORM, STRAIGHT-LINE WINDS, AND FLOODING

Federal disaster declaration (FEMA DR-4442). Flood event — may have impacted local water infrastructure.

Violation
2 drinking water violations recorded

Contaminants: Nitrate.

Violation
66 drinking water violations recorded

Contaminants: Aldicarb sulfoxide, Aldicarb sulfone, Aldicarb.

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Prior Lake's water supply.

Lead Within Limits
Detected: 0.7 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (1 compound) Elevated
Detected: Highest: lithium at 18.6000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Prior Lake's water system has 83 total violations on record, including 1 health-based violation. 6 remain unresolved.

MRMONMCL
Most recent violations:
Jan 2019 Nitrate Resolved
Jan 2019 Nitrate Resolved
Jan 2017 Aldicarb sulfoxide Resolved
Jan 2017 Aldicarb sulfone Resolved
Jan 2017 Aldicarb Resolved

Flood & environmental risk

Scott County has experienced 10 federally declared disasters since 1965. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies.

SEVERE WINTER STORM, STRAIGHT-LINE WINDS, AND FLOODING
Flood FEMA DR-4442
SEVERE STORMS, STRAIGHT-LINE WINDS, FLOODING, LANDSLIDES, AND MUDSLIDES
Flood FEMA DR-4182
SEVERE STORMS AND FLOODING
Flood FEMA DR-1982

Where does Prior Lake's water come from?

Prior Lake's drinking water comes from groundwater (wells), supplied by 3 water systems serving approximately 50,541 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate.

What Prior Lake residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Prior Lake's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Prior Lake's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.7 ppb
EPA Action Level: 15 ppb · 5% of limit
Safe Level
lithium
PFAS / Forever Chemical
Near MCL
18.6000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
1.9 µg/L
EPA MCL: 60 µg/L · 3% of limit
Within LimitUCMR 4 DataHAA6Br: 1.6 µg/LHAA9: 3.2 µg/L
Strontium
Inorganic
Detected
260.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 17% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
1.1 µg/L
EPA Secondary MCL: 50 µg/L · 2% of limit
DetectedUCMR 4 Data
Chlorate
Disinfection Byproduct
Over HA
297.0 µg/L
EPA Lifetime HA: 210 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
Molybdenum
Inorganic
Detected
2.70 µg/L
EPA Lifetime HA: 40 µg/L · 7% of limit
DetectedUCMR 3 Data
Lithium
Inorganic
Detected
18.6 µg/L
State screening level: 60 µg/L · 31% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

83
Total violations
1
Health-based
6
Active / unresolved
Jan 2019
Most recent violation
Compliance Record

Violations & advisories

83 Total
6 Active
1 Health-based
77 Resolved
Violations by category
Synthetic Organic Chemicals
66
Total Coliform Rule
6
Nitrate Rule
4
Lead and Copper Rule
4
Revised Total Coliform Rule
1
Jan 1996 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jul 1995 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jan 1995 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jul 1994 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Active
Compliance Violation
Monitoring 0
Jan 2019 Resolved
Nitrate
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2019 Resolved
Nitrate
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Aldicarb sulfoxide
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Aldicarb sulfone
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Aldicarb
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Atrazine
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
2,3,7,8-TCDD
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
HEXACHLOROBENZENE
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Total Polychlorinated Biphenyls (PCB)
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
1,2-DIBROMO-3-CHLOROPROPANE
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Chlordane
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Endrin
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
BHC-GAMMA
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Jan 2017 Resolved
Methoxychlor
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2019
Showing 20 of 83 violations
Industrial pollution

Top industrial polluters within 10 miles of Prior Lake

Industrial polluters nearby

Reported releases to surface water by facilities near Prior Lake, ranked by pounds discharged annually.

Total reported releases to surface water: 0 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
OLDCASTLE APG - SHAKOPEE
Nonmetallic Mineral Product · CRH AMERICAS INC
SHAKOPEE, MN55379
Lead07.4 mi
CEMSTONE - BURNSVILLE
Nonmetallic Mineral Product · CEMSTONE PRODUCTS CO
BURNSVILLE, MN55337
7.4 mi
ROSEMOUNT AEROSPACE INC.
Computers and Electronic Products · RTX CORP
BURNSVILLE, MN55306
6.4 mi
EMERSON AUTOMATION SOLUTIONS ROSEMOUNT INC
Computers and Electronic Products · EMERSON ELECTRIC CO
EDEN PRAIRIE, MN55344
9.4 mi
CEMSTONE - JORDAN
Nonmetallic Mineral Product · CEMSTONE PRODUCTS CO
JORDAN, MN55352
7.4 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Site context

Superfund sites within 10 miles of Prior Lake

Superfund sites nearby

Federally tracked hazardous-waste sites on the EPA National Priorities List. Proximity does not necessarily indicate tap-water contamination — the connection depends on hydrology and treatment.

Source: EPA Superfund National Priorities List

Environmental Risk

Flood & disaster history

10
Declared disasters
Jun 2019
Most recent
Flood
Most common type

Scott County has experienced 10 federally declared disasters since 1965. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Jun 2019
SEVERE WINTER STORM, STRAIGHT-LINE WINDS, AND FLOODING
Flood FEMA #4442
Jul 2014
SEVERE STORMS, STRAIGHT-LINE WINDS, FLOODING, LANDSLIDES, AND MUDSLIDES
Flood FEMA #4182
May 2011
SEVERE STORMS AND FLOODING
Flood FEMA #1982
Apr 2010
FLOODING
Flood FEMA #1900
Mar 2010
FLOODING
Flood FEMA #3310
Sep 2005
HURRICANE KATRINA EVACUATION
Hurricane FEMA #3242

Recommended water filters

Based on contaminants detected in Prior Lake's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.7 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 18.600 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 11.0 ppb from 1992 (11.0 ppb) to 2025 (0.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Local Government
Population Served
50,541
Water Systems
3
Water Source

Where Prior Lake's water comes from

Groundwater

Prior Lake's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 50,541 people through 3 water systems.

Infrastructure

Water systems serving Prior Lake

System Name PWSID Population Source
Prior Lake MN1700007 25,282 GW
SOUTH WATER TREATMENT PLANT (SWTP) 055294506 24,959 GW
NORTH WATER TREATMENT PLANT (NWTP) 055294501 300 GW
Regional Comparison

How Prior Lake compares

Full Minnesota rankings →

Prior Lake's score of 81.5/100 is on par with the average of 82/100 among major Minnesota cities. It outscores 4 of 10 nearby cities. 5 of 10 nearby cities score higher.

Prior Lake (this city)
81.5
St. Paul
73.3
Rochester
69.7
Minnesota avg
82
Service Area

ZIP codes served by Prior Lake

The water systems serving Prior Lake cover 1 ZIP code. Select any ZIP to see which water systems serve that area.

City Profile

About Prior Lake, MN

Economic Profile
$129,539
Median Income
$400,819
Median Home Value
$1,447/mo
Median Rent
1.5%
Unemployment
Community
39.4
Median Age
654
People / sq mi
51.7%
College Educated
86.2%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Prior Lake, MN tap water safe to drink?

Prior Lake's water quality earned a grade of B+ (81.5/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #405 out of 466 cities tested in Minnesota.

What contaminants are in Prior Lake's water?

Lead was measured at 0.7 ppb (90th percentile). 1 PFAS compound was detected. 83 violations are on record.

How is Prior Lake's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Prior Lake?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Prior Lake's water come from?

Prior Lake's water is sourced from Groundwater. The city has 3 water systems serving approximately 50,541 residents.

What health violations has Prior Lake's water system had?

Prior Lake has 1 health-based violation on record. The most recent violation was recorded in January 2019. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 6 violations remain unresolved.

Is Prior Lake's groundwater at risk of contamination?

Prior Lake uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 83 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Prior Lake's water compare to other cities?

Prior Lake ranks #405 out of 466 cities in Minnesota (better than 13% of state cities) and #7422 out of 15744 cities nationally (53th percentile). The grade of B+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.