WaterVerge

Is Monroe, NC Tap Water Safe to Drink?

Graded B- — but Chlorate was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

211K residents served 2 water systems PWSID: NC0190413
Overall Score
73.8 / 100
Violations
14 active
Last Updated
May 2026
Source
Surface water
#221 of 417 in North Carolina Top 64% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
B-GRADE
Water Quality Grade
73.8/100
waterverge.com
B- 73.8/100

Monroe, NC — Water Quality Report

Monroe's drinking water received a grade of B- (73.8 out of 100), indicating fair water quality. The city's 2 water systems serve approximately 210,635 residents using surface water.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 6 PFAS compounds, with levels exceeding EPA maximum contaminant levels in the water supply.

The system has 38 violations on record, including 10 health-based violations. 14 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Monroe's water

Monroe ranks #221 out of 417 cities in North Carolina for water quality, placing it below average in the state.

The city draws from surface water sources, which are more susceptible to seasonal runoff and agricultural contamination, requiring extensive multi-barrier treatment including coagulation, filtration, and disinfection.

Of particular concern: PFAS "forever chemical" levels exceed the 2024 EPA maximum contaminant levels. These synthetic compounds don't break down naturally and require specialized filtration such as reverse osmosis or granular activated carbon.

Hexavalent chromium (chromium-6) was detected at 0.20 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

Quality Breakdown

Water quality score

See methodology →
73.8 out of 100 Grade B-
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
32.2/45
C
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.0 ppb (90th percentile).
Contaminants
12.6/20
C
6 PFAS compounds detected.
Compliance
5/10
D
Monitoring and reporting compliance with EPA regulations.
Source Risk
4/5
B
Water source: Surface water.
Water Safety

Is Monroe, NC water safe to drink?

Concerns Identified

Monroe's drinking water has significant quality concerns based on EPA testing data. With a grade of B- (73.8/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 2 water systems serve approximately 210,635 residents using surface water (rivers, lakes, or reservoirs).

14
Active Violations
0.0 ppb
Lead (90th %ile)
6 compounds
PFAS Detected
7 events
Disaster History

Recent water quality updates for Monroe

A timeline of significant water quality events, violations, and data updates.

PFAS
6 PFAS "forever chemical" compounds detected

PFAS levels exceed EPA maximum contaminant levels. Reverse osmosis or activated carbon filtration recommended.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Monroe's water quality assessment. Grade: B- (73.8/100).

Violation
1 drinking water violation recorded

1 health-based. Contaminants: Revised Total Coliform Rule.

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Violation
3 drinking water violations recorded

Contaminants: Total Haloacetic Acids (HAA5), TTHM, Consumer Confidence Rule.

Disaster
HURRICANE IAN

Federal disaster declaration (FEMA DR-3586). Hurricane event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Monroe's water supply.

Lead Within Limits
Detected: 0.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (6 compounds) Elevated
Detected: Highest: PFPeA at 0.0100 µg/L Limit: 0.004 µg/L (EPA MCL)

PFAS "forever chemicals" exceed EPA maximum contaminant levels. Reverse osmosis or granular activated carbon filtration strongly recommended.

PFAS "forever chemicals" detected

UCMR 5 testing found 6 PFAS compounds in Monroe's water supply. PFAS are synthetic chemicals that persist indefinitely in the environment and the human body.

Compound Level EPA MCL Status
PFPeA 0.0100 µg/L 0.004 µg/L Within Limit
PFHxA 0.0074 µg/L 0.004 µg/L Within Limit
PFBA 0.0069 µg/L 0.004 µg/L Within Limit
PFBS 0.0056 µg/L 0.004 µg/L Within Limit

Violation history

Monroe's water system has 38 total violations on record, including 10 health-based violations. 14 remain unresolved. 5 violations were issued in the last 5 years.

MCLRPTMROther
Most recent violations:
Aug 2025 Revised Total Coliform Rule Resolved
Apr 2025 Revised Total Coliform Rule Open
Jul 2024 Total Haloacetic Acids (HAA5) Resolved
Jul 2024 TTHM Resolved
Jul 2024 Consumer Confidence Rule Open

Flood & environmental risk

Union County has experienced 7 federally declared disasters since 2004. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Goose, Goose Creek.

HURRICANE IAN
Hurricane FEMA DR-3586
HURRICANE ISAIAS
Hurricane FEMA DR-3534
HURRICANE DORIAN
Hurricane FEMA DR-3423

Where does Monroe's water come from?

Monroe's drinking water comes from surface water (rivers, lakes, or reservoirs), supplied by 2 water systems serving approximately 210,635 people. Surface water sources are more susceptible to contamination from runoff, industrial discharge, and algal blooms, requiring extensive treatment. Nearby water bodies include Goose (river), Goose Creek (river).

What Monroe residents can do

Install a water filter

Recommended: Reverse osmosis system. This addresses the specific contaminants found in Monroe's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Monroe's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.0 ppb
EPA Action Level: 15 ppb · 0% of limit
Safe Level
PFPeA
PFAS / Forever Chemical
Near MCL
0.0100 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
PFHxA
PFAS / Forever Chemical
Near MCL
0.0074 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
25.0 µg/L
EPA MCL: 60 µg/L · 42% of limit
Within LimitUCMR 4 DataHAA6Br: 6.0 µg/LHAA9: 30.6 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
0.20 µg/L
CA MCL (no federal MCL): 10 µg/L · 2% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
130.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 9% of limit
DetectedUCMR 3 Data
1,4-Dioxane
Organic
Elevated
0.27 µg/L
EPA Health Advisory: 0.35 µg/L · 77% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
12.0 µg/L
EPA Secondary MCL: 50 µg/L · 24% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Detected
1.30 µg/L
EPA Short-term HA: 21 µg/L · 6% of limit
DetectedUCMR 3 Data
Chlorate
Disinfection Byproduct
Over HA
526.0 µg/L
EPA Lifetime HA: 210 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
6
Detected
2
Exceed EPA MCL
2.27
Hazard Index
PFOS max: 0.0049 µg/L PFOA max: 0.0042 µg/L
Compliance Record

Violation summary

38
Total violations
10
Health-based
14
Active / unresolved
Aug 2025
Most recent violation
Compliance Record

Violations & advisories

38 Total
14 Active
10 Health-based
24 Resolved
1 SNC
Violations by category
Stage 1 Disinfectants and Disinfection Byproducts Rule
9
Public Notice Rule and Revised PN Rule
7
Revised Total Coliform Rule
5
Synthetic Organic Chemicals
5
Stage 2 Disinfectants and Disinfection Byproducts Rule
3
Apr 2025 Active
Revised Total Coliform Rule
Reporting
Reporting 0
Jul 2024 Active
Consumer Confidence Rule
Other Violation 0
May 2020 Active
Revised Total Coliform Rule
Reporting
Reporting 0
Oct 2018 Active
Revised Total Coliform Rule
Reporting
Reporting 0
Oct 2010 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Mar 2010 Active
Public Notice
Other Violation 0
Apr 2007 Active
Public Notice
Other Violation 0
Oct 2005 Active
Public Notice
Other Violation 0
Feb 2004 Active
Public Notice
Other Violation 0
Oct 2003 Active
Public Notice
Other Violation 0
Nov 2002 Active
Public Notice
Other Violation 0
Nov 2002 Active
Public Notice
Other Violation 0
Active
Compliance Violation
Monitoring 0
Active
Compliance Violation
Monitoring 0
Aug 2025 Resolved
Revised Total Coliform Rule
Max Contaminant Level
Health-Based Health Resolved Aug 2025
Jul 2024 Resolved
Total Haloacetic Acids (HAA5)
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2024
Jul 2024 Resolved
TTHM
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2024
Mar 2020 Resolved
Revised Total Coliform Rule
Max Contaminant Level
Health-Based Health Resolved Mar 2020
Jul 2017 Resolved
Total Haloacetic Acids (HAA5)
Max Contaminant Level
SNC Health Resolved Sep 2017
May 2009 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved May 2009
Showing 20 of 38 violations
Industrial pollution

Top industrial polluters within 10 miles of Monroe

Industrial polluters nearby

Reported releases to surface water by facilities near Monroe, ranked by pounds discharged annually.

Total reported releases to surface water: 23 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
ATI SPECIALTY MATERIALS - BAKERS SITE
Primary Metals · ATI INC
MONROE, NC28110
Copper103.1 mi
ATI SPECIALTY MATERIALS - MONROE PLANT
Primary Metals · ATI INC
MONROE, NC28110
Chromium42.7 mi
CONCRETE SUPPLY CO - MATTHEWS
Nonmetallic Mineral Product · CONCRETE SUPPLY CO LLC
MATTHEWS, NC28104
Nitrate compounds (water dissociable; reportable only when in aqueous solution)49.7 mi
CIRCOR PUMPS N.A. LLC
Machinery · CIRCOR INTERNATIONAL INC
MONROE, NC28110
Lead23.7 mi
YALE SECURITY INC.,NORTON DOOR CONTROLS
Fabricated Metals · ASSA ABLOY INC
MONROE, NC28112
Copper25.9 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Environmental Risk

Drought conditions

D4 — exceptional drought

Union County is currently in D4 (exceptional drought) per the U.S. Drought Monitor (week of May 5, 2026). 46.2% of the county is in D4 (exceptional) drought. Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

14
Weeks at D2+ (current streak)
31.8%
Months in D2+ (last 30y)
14
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

7
Declared disasters
Oct 2022
Most recent
Hurricane
Most common type

Union County has experienced 7 federally declared disasters since 2004. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Oct 2022
HURRICANE IAN
Hurricane FEMA #3586
Aug 2020
HURRICANE ISAIAS
Hurricane FEMA #3534
Sep 2019
HURRICANE DORIAN
Hurricane FEMA #3423
Sep 2018
HURRICANE FLORENCE
Hurricane FEMA #4393
Sep 2018
HURRICANE FLORENCE
Hurricane FEMA #3401
Sep 2005
HURRICANE KATRINA EVACUATION
Hurricane FEMA #3222

Recommended water filters

Based on contaminants detected in Monroe's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
PFAS compounds exceed EPA maximum contaminant levels

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium ND HI µg/L PFAS Not Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA 0.007 HI µg/L PFAS Detected
PFBS 0.006 HI µg/L PFAS Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA 0.007 HI µg/L PFAS Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA 0.004 0.004 µg/L PFAS Over MCL
PFOS 0.005 0.004 µg/L PFAS Over MCL
PFPeA 0.010 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 11.0 ppb from 1992 (11.0 ppb) to 2025 (0.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Surface Water
Operator
Local Government
Population Served
210,635
Water Systems
2
Water Source

Where Monroe's water comes from

Surface Water

Monroe's drinking water comes primarily from surface water sources such as rivers, lakes, or reservoirs.

Surface water systems require multi-stage treatment including coagulation, sedimentation, filtration, and disinfection to meet EPA Safe Drinking Water Act standards.

These sources can be impacted by seasonal changes, stormwater runoff, upstream agriculture, and industrial discharge.

The system is operated by local government ownership and serves approximately 210,635 people through 2 water systems.

Local Hydrology

Water bodies near Monroe

Monroe is located near 2 notable water bodies. As a surface water system, these water bodies may directly influence the city's drinking water supply.

Goose
river
Goose Creek
river
Infrastructure

Water systems serving Monroe

System Name PWSID Population Source
UNION COUNTY WATER SYSTEM NC0190413 167,554 SW
MONROE, CITY OF NC0190010 43,081 SW
Regional Comparison

How Monroe compares

Full North Carolina rankings →

Monroe's score of 73.8/100 is above the average of 42/100 among major North Carolina cities. It outscores 9 of 10 nearby cities.

Monroe (this city)
73.8
Charlotte
36.5
Raleigh
30.7
Durham
36.6
Greensboro
33.5
North Carolina avg
42
City Profile

About Monroe, NC

Wikipedia →

Monroe is a city in and the county seat of Union County, North Carolina, United States. The population increased from 32,797 in 2010 to 34,551 in 2020, and the 28th most populous city in North Carolina. It is within the rapidly growing Charlotte metropolitan area. Monroe has a council-manager form of government.

Economic Profile
$63,982
Median Income
$232,779
Median Home Value
$1,115/mo
Median Rent
6.2%
Unemployment
Community
36.1
Median Age
436
People / sq mi
20.9%
College Educated
59.5%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Monroe, NC tap water safe to drink?

Monroe's water quality earned a grade of B- (73.8/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #221 out of 417 cities tested in North Carolina.

What contaminants are in Monroe's water?

Lead was measured at 0.0 ppb (90th percentile). 6 PFAS compounds were detected. 38 violations are on record.

How is Monroe's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Monroe?

PFAS compounds exceed EPA limits — a reverse osmosis or activated carbon filter is recommended.

Where does Monroe's water come from?

Monroe's water is sourced from Surface water. The city has 2 water systems serving approximately 210,635 residents.

What health violations has Monroe's water system had?

Monroe has 10 health-based violations on record. The most recent violation was recorded in August 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 14 violations remain unresolved.

Why does Monroe have so many PFAS compounds in its water?

6 different PFAS "forever chemical" compounds were detected in Monroe's water supply during UCMR 5 testing. PFAS contamination often originates from proximity to military installations (AFFF firefighting foam), airports, industrial manufacturing sites, or wastewater treatment facilities. Some levels exceed the 2024 EPA maximum contaminant levels — a reverse osmosis or NSF-certified activated carbon filter is strongly recommended.

How does Monroe's water compare to other cities?

Monroe ranks #221 out of 417 cities in North Carolina (better than 47% of state cities) and #9997 out of 15744 cities nationally (37th percentile). The grade of B- reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.