WaterVerge

Is Minot, ND Tap Water Safe to Drink?

Graded B+ — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

60K residents served 5 water systems PWSID: ND5100660
Overall Score
83.2 / 100
Violations
6 active
Last Updated
May 2026
Source
Groundwater
#74 of 103 in North Dakota Top 42% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
B+GRADE
Water Quality Grade
83.2/100
waterverge.com
B+ 83.2/100

Minot, ND — Water Quality Report

Minot's drinking water received a grade of B+ (83.2 out of 100), indicating good water quality. The city's 5 water systems serve approximately 59,713 residents using groundwater.

Lead levels were measured at 1.4 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 2 PFAS compounds in the water supply.

The system has 24 violations on record, including 2 health-based violations. 6 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Minot's water

Minot ranks #74 out of 103 cities in North Dakota for water quality, placing it below average in the state.

Minot relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Hexavalent chromium (chromium-6) was detected at 1.57 µg/L in UCMR 3 testing. While below California's 10 µg/L limit and with no federal MCL set, residents sensitive to this contaminant may consider reverse osmosis filtration.

The system has seen 6 violations in the past five years, suggesting a pattern of compliance challenges that residents should monitor closely.

Quality Breakdown

Water quality score

See methodology →
83.2 out of 100 Grade B+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
39.2/45
B
Historical violation record including health-based and monitoring violations.
Lead & Copper
16/20
B
Lead at 1.4 ppb (90th percentile).
Contaminants
17.9/20
B
2 PFAS compounds detected.
Compliance
5/10
D
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Minot, ND water safe to drink?

Concerns Identified

Minot's drinking water has significant quality concerns based on EPA testing data. With a grade of B+ (83.2/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 5 water systems serve approximately 59,713 residents using groundwater (wells).

6
Active Violations
1.4 ppb
Lead (90th %ile)
2 compounds
PFAS Detected
10 events
Disaster History

Recent water quality updates for Minot

A timeline of significant water quality events, violations, and data updates.

PFAS
2 PFAS "forever chemical" compounds detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Minot's water quality assessment. Grade: B+ (83.2/100).

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Violation
1 drinking water violation recorded

Contaminants: Chloramine.

Violation
1 drinking water violation recorded

Contaminants: E. COLI.

Disaster
SEVERE STORMS AND FLOODING

Federal disaster declaration (FEMA DR-4190). Flood event — may have impacted local water infrastructure.

Key contaminant findings

Based on the most recent EPA sampling data for Minot's water supply.

Lead Within Limits
Detected: 1.4 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Copper Exceeds Limit
Detected: 1.47 mg/L Limit: 1.3 mg/L (EPA Action Level)

Exceeds EPA action level. Copper can leach from household plumbing — flush taps for 30 seconds before drinking.

PFAS (2 compounds) Elevated
Detected: Highest: lithium at 78.0000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

PFAS "forever chemicals" detected

UCMR 5 testing found 2 PFAS compounds in Minot's water supply. PFAS are synthetic chemicals that persist indefinitely in the environment and the human body.

Compound Level EPA MCL Status
lithium 78.0000 µg/L 0.004 µg/L Within Limit
PFPeA 0.0030 µg/L 0.004 µg/L Within Limit

Violation history

Minot's water system has 24 total violations on record, including 2 health-based violations. 6 remain unresolved. 6 violations were issued in the last 5 years.

MONMRTTMCL
Most recent violations:
Mar 2023 Revised Total Coliform Rule Resolved
Jan 2023 Chloramine Resolved
Nov 2022 E. COLI Open
Sep 2021 Revised Total Coliform Rule Resolved
Aug 2021 Lead and Copper Rule Open

Flood & environmental risk

Ward County has experienced 10 federally declared disasters since 1976. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Souris River Above Minot, Souris River.

SEVERE STORMS AND FLOODING
Flood FEMA DR-4190
FLOODING
Flood FEMA DR-1981
FLOODING
Flood FEMA DR-3318

Where does Minot's water come from?

Minot's drinking water comes from groundwater (wells), supplied by 5 water systems serving approximately 59,713 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Souris River Above Minot (river), Souris River (river).

What Minot residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Minot's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Minot's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
1.4 ppb
EPA Action Level: 15 ppb · 9% of limit
Safe Level
Copper (90th percentile)
Inorganic
Over Limit
1.47 mg/L
EPA Action Level: 1.3 mg/L · +13% over limit
Exceeds Limit
lithium
PFAS / Forever Chemical
Near MCL
78.0000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
13.4 µg/L
EPA MCL: 60 µg/L · 22% of limit
Within LimitUCMR 4 DataHAA6Br: 22.5 µg/LHAA9: 26.6 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Detected
1.57 µg/L
CA MCL (no federal MCL): 10 µg/L · 16% of limit
DetectedUCMR 3 Data
Strontium
Inorganic
Detected
188.7 µg/L
EPA Health Ref Level: 1,500 µg/L · 13% of limit
DetectedUCMR 3 Data
Vanadium
Inorganic
Detected
4.10 µg/L
EPA Short-term HA: 21 µg/L · 20% of limit
DetectedUCMR 3 Data
Molybdenum
Inorganic
Detected
8.10 µg/L
EPA Lifetime HA: 40 µg/L · 20% of limit
DetectedUCMR 3 Data
Lithium
Inorganic
Above state screening
78.0 µg/L
State screening level: 60 µg/L · +20% over limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
2
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

24
Total violations
2
Health-based
6
Active / unresolved
Mar 2023
Most recent violation
Compliance Record

Violations & advisories

24 Total
6 Active
2 Health-based
18 Resolved
Violations by category
Total Coliform Rule
7
Stage 1 Disinfectants and Disinfection Byproducts Rule
6
Revised Total Coliform Rule
3
Lead and Copper Rule
3
Ground Water Rule
1
Nov 2022 Active
E. COLI
Monitoring & Reporting
Monitoring & Reporting 0
Aug 2021 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Oct 2012 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jan 2010 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Active
Compliance Violation
Monitoring 0
Mar 2023 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Mar 2023
Jan 2023 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2023
Sep 2021 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Sep 2021
Jul 2021 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2021
Apr 2019 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2019
Apr 2017 Resolved
Revised Total Coliform Rule
Monitoring
Monitoring Resolved Apr 2017
Apr 2017 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2017
May 2015 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved May 2015
Apr 2015 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2015
Jun 2012 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2012
Apr 2012 Resolved
Chloramine
Monitoring & Reporting
Monitoring & Reporting Resolved Jun 2012
Jan 2009 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Jan 2009
May 2008 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved May 2008
Oct 2007 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Oct 2007
Showing 20 of 24 violations
Environmental Risk

Flood & disaster history

10
Declared disasters
Aug 2014
Most recent
Flood
Most common type

Ward County has experienced 10 federally declared disasters since 1976. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Aug 2014
SEVERE STORMS AND FLOODING
Flood FEMA #4190
May 2011
FLOODING
Flood FEMA #1981
Apr 2011
FLOODING
Flood FEMA #3318
Apr 2010
FLOODING
Flood FEMA #1907
Sep 2005
HURRICANE KATRINA EVACUATION
Coastal Storm FEMA #3247
Jun 1999
SEVERE STORMS, FLOODING, SNOW, ICE, GROUND SATURATION, LANSLIDES, MUDSLIDES, AND TOR
Flood FEMA #1279

Recommended water filters

Based on contaminants detected in Minot's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
2 PFAS compounds detected
🔧
For Copper
Reverse Osmosis or KDF Filter
Copper exceeds the EPA action level of 1.3 mg/L

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.4 15 ppb Inorganic Safe
Copper (90th percentile) 1.47 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 78.000 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA 0.003 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 6.0 ppb from 1992 (7.4 ppb) to 2025 (1.4 ppb).

Copper level (90th percentile)

Latest reading: 1.470 mg/L (2009)

EPA action level: 1.3 mg/L

Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Local Government
Population Served
59,713
Water Systems
5
Source breakdown
Groundwater
2
Purchased Groundwater
2
Purchased Surface Water
1
Water Source

Where Minot's water comes from

Groundwater

Minot's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 59,713 people through 5 water systems.

Local Hydrology

Water bodies near Minot

Minot is located near 2 notable water bodies. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Souris River Above Minot
river
Souris River
river
Infrastructure

Water systems serving Minot

System Name PWSID Population Source
MINOT CITY OF ND5100660 48,743 GW
NORTH PRAIRIE RWD-SYSTEM 1&2 ND5101125 7,748 GWP
NORTH PRAIRIE RWD-SYSTEM III ND5101065 2,742 GW
WEST RIVER WATER AND SEWER ND5101447 450 GWP
NORTH PRAIRIE RWD SYSTEM IV ND3101807 30 SWP
Regional Comparison

How Minot compares

Full North Dakota rankings →

Minot's score of 83.2/100 is on par with the average of 83/100 among major North Dakota cities. It outscores 4 of 10 nearby cities. 6 of 10 nearby cities score higher.

Minot (this city)
83.2
Fargo
91.5
Bismarck
85.7
West Fargo
92.2
North Dakota avg
83
City Profile

About Minot, ND

Wikipedia →

Minot is a city in and the county seat of Ward County, North Dakota, United States. With a population of 48,377 at the 2020 census, Minot is the state's fourth-most populous city. The Minot metropolitan area in north-central North Dakota covers McHenry, Renville, and Ward counties and had a combined population of 77,546 at the 2020 census.

Economic Profile
$75,545
Median Income
$238,495
Median Home Value
$937/mo
Median Rent
3.7%
Unemployment
Community
33
Median Age
670
People / sq mi
30%
College Educated
56.6%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Minot, ND tap water safe to drink?

Minot's water quality earned a grade of B+ (83.2/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #74 out of 103 cities tested in North Dakota.

What contaminants are in Minot's water?

Lead was measured at 1.4 ppb (90th percentile). 2 PFAS compounds were detected. 24 violations are on record.

How is Minot's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Minot?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Minot's water come from?

Minot's water is sourced from Groundwater. The city has 5 water systems serving approximately 59,713 residents.

What health violations has Minot's water system had?

Minot has 2 health-based violations on record. The most recent violation was recorded in March 2023. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 6 violations remain unresolved.

Is Minot's groundwater at risk of contamination?

Minot uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 24 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Minot's water compare to other cities?

Minot ranks #74 out of 103 cities in North Dakota (better than 28% of state cities) and #6516 out of 15744 cities nationally (59th percentile). The grade of B+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.