WaterVerge

Is Manti, UT Tap Water Safe to Drink?

Graded B+ — but Copper was detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

3K residents served 1 water system PWSID: UTAH20005
Overall Score
82.7 / 100
Violations
3 active
Last Updated
May 2026
Source
Ground water under influence
#63 of 177 in Utah Top 43% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
B+GRADE
Water Quality Grade
82.7/100
waterverge.com
B+ 82.7/100

Manti, UT — Water Quality Report

Manti's drinking water received a grade of B+ (82.7 out of 100), indicating good water quality. The city's 1 water system serves approximately 3,429 residents using ground water under influence.

Lead levels were measured at 1.9 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 1 PFAS compound in the water supply.

The system has 45 violations on record, including 1 health-based violation. 3 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Manti's water

Manti ranks #63 out of 177 cities in Utah for water quality, placing it mid-range in the state.

Manti relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

PFAS compounds were detected in testing, though levels remain within current EPA limits. Residents seeking extra precaution may consider an activated carbon or reverse osmosis filter.

Quality Breakdown

Water quality score

See methodology →
82.7 out of 100 Grade B+
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
40.9/45
A
Historical violation record including health-based and monitoring violations.
Lead & Copper
16/20
B
Lead at 1.9 ppb (90th percentile).
Contaminants
14.2/20
C
1 PFAS compound detected.
Compliance
8/10
B
Monitoring and reporting compliance with EPA regulations.
Source Risk
3.5/5
C
Water source: Ground water under influence.
Water Safety

Is Manti, UT water safe to drink?

Concerns Identified

Manti's drinking water has significant quality concerns based on EPA testing data. With a grade of B+ (82.7/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 1 water system serves approximately 3,429 residents using groundwater (wells).

3
Active Violations
1.9 ppb
Lead (90th %ile)
1 compound
PFAS Detected
5 events
Disaster History

Recent water quality updates for Manti

A timeline of significant water quality events, violations, and data updates.

PFAS
1 PFAS "forever chemical" compound detected

Detected at levels within current EPA limits. PFAS persist indefinitely in the environment.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Manti's water quality assessment. Grade: B+ (82.7/100).

Violation
1 drinking water violation recorded

Contaminants: Nitrate.

Disaster
FLOODING

Federal disaster declaration (FEMA DR-4752). Flood event — may have impacted local water infrastructure.

Violation
3 drinking water violations recorded

Contaminants: Radium-226, Radium-228, Gross Alpha, Excl. Radon and U.

Violation
1 drinking water violation recorded

Contaminants: Revised Total Coliform Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Manti's water supply.

Lead Within Limits
Detected: 1.9 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

Copper Exceeds Limit
Detected: 1.63 mg/L Limit: 1.3 mg/L (EPA Action Level)

Exceeds EPA action level. Copper can leach from household plumbing — flush taps for 30 seconds before drinking.

PFAS (1 compound) Elevated
Detected: Highest: lithium at 24.9000 µg/L Limit: 0.004 µg/L (EPA MCL)

Detected but within current EPA limits. PFAS do not break down in the environment and can accumulate in the body over time. An activated carbon filter can reduce exposure.

Violation history

Manti's water system has 45 total violations on record, including 1 health-based violation. 3 remain unresolved. 1 violation was issued in the last 5 years.

MRRPTOtherTT
Most recent violations:
Jan 2025 Nitrate Resolved
Jan 2017 Radium-226 Resolved
Jan 2017 Radium-228 Resolved
Jan 2017 Gross Alpha, Excl. Radon and U Resolved
Jun 2016 Revised Total Coliform Rule Open

Flood & environmental risk

Sanpete County has experienced 5 federally declared disasters since 1983. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Manti Creek.

FLOODING
Flood FEMA DR-4752
FLOODING
Flood FEMA DR-4011
HURRICANE KATRINA EVACUATION
Coastal Storm FEMA DR-3223

Where does Manti's water come from?

Manti's drinking water comes from groundwater (wells), supplied by 1 water system serving approximately 3,429 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Manti Creek (river).

What Manti residents can do

Install a water filter

Recommended: Activated carbon or reverse osmosis filter. This addresses the specific contaminants found in Manti's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Manti's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
1.9 ppb
EPA Action Level: 15 ppb · 13% of limit
Safe Level
Copper (90th percentile)
Inorganic
Over Limit
1.63 mg/L
EPA Action Level: 1.3 mg/L · +20% over limit
Exceeds Limit
lithium
PFAS / Forever Chemical
Near MCL
24.9000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
Lithium
Inorganic
Detected
24.9 µg/L
State screening level: 60 µg/L · 42% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
1
Detected
0
Exceed EPA MCL
Compliance Record

Violation summary

45
Total violations
1
Health-based
3
Active / unresolved
Jan 2025
Most recent violation
Compliance Record

Violations & advisories

45 Total
3 Active
1 Health-based
42 Resolved
Violations by category
Inorganic Chemicals
23
Nitrate Rule
5
Radionuclides and Revised Rad Rule
5
Total Coliform Rule
4
Arsenic Rule
3
Jun 2016 Active
Revised Total Coliform Rule
Reporting
Reporting 0
Oct 2010 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Active
Compliance Violation
Monitoring 0
Jan 2025 Resolved
Nitrate
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2025
Jan 2017 Resolved
Radium-226
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2017
Jan 2017 Resolved
Radium-228
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2017
Jan 2017 Resolved
Gross Alpha, Excl. Radon and U
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2017
Jul 2013 Resolved
Chlorine
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2013
Jul 2008 Resolved
Nitrate
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 2008
Mar 2002 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Mar 2002
Sep 1998 Resolved
Coliform (TCR)
Other Violation Resolved Sep 1998
Sep 1998 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 1998
Jul 1997 Resolved
Surface Water Treatment Rule
Treatment Technique
Health-Based Health Resolved Aug 1997
Nov 1994 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Nov 1994
Jan 1993 Resolved
Nitrite
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1993
Jan 1992 Resolved
Gross Beta Particle Activity
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1995
Jan 1992 Resolved
Gross Alpha, Excl. Radon and U
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1995
Jan 1991 Resolved
CYANIDE
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1993
Jan 1991 Resolved
Cadmium
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1993
Jan 1991 Resolved
Nickel
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 1993
Showing 20 of 45 violations
Environmental Risk

Drought conditions

D3 — extreme drought

Sanpete County is currently in D3 (extreme drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

14
Weeks at D2+ (current streak)
22.0%
Months in D2+ (last 30y)
14
Weeks at D2+ (last 5y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

5
Declared disasters
Dec 2023
Most recent
Flood
Most common type

Sanpete County has experienced 5 federally declared disasters since 1983. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Dec 2023
FLOODING
Flood FEMA #4752
Aug 2011
FLOODING
Flood FEMA #4011
Sep 2005
HURRICANE KATRINA EVACUATION
Coastal Storm FEMA #3223
Aug 1984
SEVERE STORMS, MUDSLIDES, LANDSLIDES & FLOODING
Flood FEMA #720
Apr 1983
SEVERE STORMS, LANDSLIDES & FLOODING
Flood FEMA #680

Recommended water filters

Based on contaminants detected in Manti's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
1 PFAS compound detected
🔧
For Copper
Reverse Osmosis or KDF Filter
Copper exceeds the EPA action level of 1.3 mg/L

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 1.9 15 ppb Inorganic Safe
Copper (90th percentile) 1.63 1.3 mg/L Inorganic Over Limit
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS ND HI µg/L PFAS Not Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 24.900 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA ND HI µg/L PFAS Not Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA ND HI µg/L PFAS Not Detected
PFHxS ND HI µg/L PFAS Not Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA ND 0.004 µg/L PFAS Not Detected
PFOS ND 0.004 µg/L PFAS Not Detected
PFPeA ND HI µg/L PFAS Not Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 1.3 ppb from 1993 (3.0 ppb) to 2025 (1.7 ppb).

Copper level trend (90th percentile)

EPA action level: 1.3 mg/L
Copper has decreased by 0.000 mg/L from 2023 (1.631 mg/L) to 2025 (1.631 mg/L).
Infrastructure

Water source & infrastructure

Primary Source
Ground Water Under Influence
Operator
Local Government
Population Served
3,429
Water Systems
1
Water Source

Where Manti's water comes from

Ground Water Under Influence

Manti's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 3,429 people through 1 water system.

Local Hydrology

Water bodies near Manti

Manti is located near 1 notable water body. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Manti Creek
river
Infrastructure

Water systems serving Manti

System Name PWSID Population Source
MANTI CITY UTAH20005 3,429 GU
Regional Comparison

How Manti compares

Full Utah rankings →

Manti's score of 82.7/100 is above the average of 50/100 among major Utah cities. It outscores 10 of 10 nearby cities.

Manti (this city)
82.7
Orem
40.7
Sandy
39.5
Lehi
44.9
Utah avg
50
City Profile

About Manti, UT

Wikipedia →

Manti is a city in and the county seat of Sanpete County, Utah, United States. The population was 3,429 at the 2020 United States Census.

Economic Profile
$53,750
Median Income
$236,611
Median Home Value
$1,042/mo
Median Rent
1.7%
Unemployment
Community
36.2
Median Age
425
People / sq mi
24.3%
College Educated
75.3%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Manti, UT tap water safe to drink?

Manti's water quality earned a grade of B+ (82.7/100). The water generally meets EPA standards and is considered safe for consumption. The city ranks #63 out of 177 cities tested in Utah.

What contaminants are in Manti's water?

Lead was measured at 1.9 ppb (90th percentile). 1 PFAS compound was detected. 45 violations are on record.

How is Manti's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Manti?

PFAS compounds have been detected. A filter with activated carbon can help reduce exposure.

Where does Manti's water come from?

Manti's water is sourced from Ground water under influence. The city has 1 water system serving approximately 3,429 residents.

What health violations has Manti's water system had?

Manti has 1 health-based violation on record. The most recent violation was recorded in January 2025. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 3 violations remain unresolved.

Is Manti's groundwater at risk of contamination?

Manti uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 45 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

How does Manti's water compare to other cities?

Manti ranks #63 out of 177 cities in Utah (better than 64% of state cities) and #6813 out of 15744 cities nationally (57th percentile). The grade of B+ reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.