WaterVerge

Is Hesperia, CA Tap Water Safe to Drink?

Graded B — but Chromium-6 and Vanadium were detected above EPA limits. Here's what's in the water and how to remove it. What to do next ↓

101K residents served 2 water systems PWSID: CA3610024
Overall Score
76.2 / 100
Violations
5 active
Last Updated
May 2026
Source
Groundwater
#442 of 694 in California Top 60% nationally
Local Government
High data confidence
Reviewed by WaterVerge Editorial Team · Last updated May 2026
BGRADE
Water Quality Grade
76.2/100
waterverge.com
B 76.2/100

Hesperia, CA — Water Quality Report

Hesperia's drinking water received a grade of B (76.2 out of 100), indicating good water quality. The city's 2 water systems serve approximately 100,894 residents using groundwater.

Lead levels were measured at 0.0 ppb (90th percentile), well within EPA limits. UCMR 5 testing detected 8 PFAS compounds, with levels exceeding EPA maximum contaminant levels in the water supply.

The system has 9 violations on record, including 2 health-based violations. 5 remain unresolved.

Data last updated: May 2026 · Source: EPA SDWIS, UCMR 5
Analysis

What to know about Hesperia's water

Hesperia ranks #442 out of 694 cities in California for water quality, placing it below average in the state.

Hesperia relies on groundwater, which is generally less vulnerable to surface contamination but can be affected by naturally occurring minerals like arsenic and nitrate, as well as agricultural and industrial runoff.

Of particular concern: PFAS "forever chemical" levels exceed the 2024 EPA maximum contaminant levels. These synthetic compounds don't break down naturally and require specialized filtration such as reverse osmosis or granular activated carbon.

Hexavalent chromium (chromium-6) was detected at 18.00 µg/L, above California's 10 µg/L limit. There is no federal MCL, but the EPA is reviewing evidence linking long-term exposure to cancer risk.

Quality Breakdown

Water quality score

See methodology →
76.2 out of 100 Grade B
A: 90-100
B: 74-89
C: 60-73
F: <50
How is this calculated?
Violations
37.6/45
B
Historical violation record including health-based and monitoring violations.
Lead & Copper
20/20
A
Lead at 0.0 ppb (90th percentile).
Contaminants
10.6/20
D
8 PFAS compounds detected.
Compliance
3/10
F
Monitoring and reporting compliance with EPA regulations.
Source Risk
5/5
A
Water source: Groundwater.
Water Safety

Is Hesperia, CA water safe to drink?

Concerns Identified

Hesperia's drinking water has significant quality concerns based on EPA testing data. With a grade of B (76.2/100), the system has issues across multiple categories. A water filter is recommended for all residents. The city's 2 water systems serve approximately 100,894 residents using groundwater (wells).

5
Active Violations
0.0 ppb
Lead (90th %ile)
8 compounds
PFAS Detected
10 events
Disaster History

Recent water quality updates for Hesperia

A timeline of significant water quality events, violations, and data updates.

PFAS
8 PFAS "forever chemical" compounds detected

PFAS levels exceed EPA maximum contaminant levels. Reverse osmosis or activated carbon filtration recommended.

Update
Water quality data updated

Latest EPA compliance and testing data incorporated into Hesperia's water quality assessment. Grade: B (76.2/100).

Violation
2 drinking water violations recorded

1 health-based. Contaminants: LEAD AND COPPER RULE REVISIONS.

Disaster
SEVERE WINTER STORMS, FLOODING, LANDSLIDES, AND MUDSLIDES

Federal disaster declaration (FEMA DR-3592). Flood event — may have impacted local water infrastructure.

Disaster
SEVERE WINTER STORMS, FLOODING, AND MUDSLIDES

Federal disaster declaration (FEMA DR-3591). Flood event — may have impacted local water infrastructure.

Violation
1 drinking water violation recorded

Contaminants: Consumer Confidence Rule.

Key contaminant findings

Based on the most recent EPA sampling data for Hesperia's water supply.

Lead Within Limits
Detected: 0.0 ppb Limit: 15 ppb (EPA Action Level)

Well within EPA limits.

PFAS (8 compounds) Elevated
Detected: Highest: lithium at 10.2000 µg/L Limit: 0.004 µg/L (EPA MCL)

PFAS "forever chemicals" exceed EPA maximum contaminant levels. Reverse osmosis or granular activated carbon filtration strongly recommended.

Chromium-6 (Hexavalent Chromium) Exceeds Limit
Detected: 18.00 µg/L Limit: 10 µg/L (California MCL — no federal limit)

The "Erin Brockovich" chemical. There is no federal MCL, but California has set a limit of 10 µg/L. Reverse osmosis filtration is effective at removing hexavalent chromium.

PFAS "forever chemicals" detected

UCMR 5 testing found 8 PFAS compounds in Hesperia's water supply. PFAS are synthetic chemicals that persist indefinitely in the environment and the human body.

Compound Level EPA MCL Status
lithium 10.2000 µg/L 0.004 µg/L Within Limit
6:2 FTS 0.0503 µg/L 0.004 µg/L Within Limit
PFOS 0.0111 µg/L 0.004 µg/L Over MCL
PFHxS 0.0105 µg/L 0.004 µg/L Within Limit

Violation history

Hesperia's water system has 9 total violations on record, including 2 health-based violations. 5 remain unresolved. 4 violations were issued in the last 5 years.

RPTTTOtherMRMCL
Most recent violations:
Oct 2024 LEAD AND COPPER RULE REVISIONS Open
Oct 2024 LEAD AND COPPER RULE REVISIONS Open
Jul 2022 Consumer Confidence Rule Open
Jan 2021 Nitrite Resolved
Jul 2020 Consumer Confidence Rule Open

Flood & environmental risk

San Bernardino County has experienced 10 federally declared disasters since 1980. Flooding and severe storms can overwhelm water treatment plants, cause sewage overflows, and introduce agricultural runoff, bacteria, and sediment into drinking water supplies. Local water sources include Deep C Nr Hesperia, Wf Mojave R Ab Mojave R Forks Res Nr Hesperia.

SEVERE WINTER STORMS, FLOODING, LANDSLIDES, AND MUDSLIDES
Flood FEMA DR-3592
SEVERE WINTER STORMS, FLOODING, AND MUDSLIDES
Flood FEMA DR-3591
SEVERE WINTER STORMS, FLOODING, AND DEBRIS AND MUD FLOWS
Flood FEMA DR-1952

Where does Hesperia's water come from?

Hesperia's drinking water comes from groundwater (wells), supplied by 2 water systems serving approximately 100,894 people. Groundwater is generally less susceptible to surface contamination but can contain naturally occurring contaminants like arsenic, radon, and nitrate. Nearby water bodies include Deep C Nr Hesperia (river), Wf Mojave R Ab Mojave R Forks Res Nr Hesperia (river).

What Hesperia residents can do

Install a water filter

Recommended: Reverse osmosis system. This addresses the specific contaminants found in Hesperia's water.

Request your utility's CCR

Your water utility is required to publish an annual Consumer Confidence Report (CCR) with detailed testing results. Ask for the latest copy or check your utility's website.

Monitor alerts during storms

Hesperia's area has a history of flooding. After severe weather, watch for boil water advisories from your local utility.

Data: EPA SDWIS, UCMR 5 (PFAS), FEMA, NOAA. Last updated May 2026.

Contaminant Alerts

Top contaminants to know

View all ↓
Lead (90th percentile)
Inorganic / Heavy Metal
Safe
0.0 ppb
EPA Action Level: 15 ppb · 0% of limit
Safe Level
lithium
PFAS / Forever Chemical
Near MCL
10.2000 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
6:2 FTS
PFAS / Forever Chemical
Near MCL
0.0503 µg/L
EPA MCL: 0.004 µg/L · +20% over limit
Detected
HAA5 (Disinfection Byproducts)
Disinfection Byproduct
Safe
0.1 µg/L
EPA MCL: 60 µg/L · 0% of limit
Within LimitUCMR 4 DataHAA6Br: 0.1 µg/LHAA9: 0.1 µg/L
Chromium-6 (Hexavalent Chromium)
Inorganic
Over CA Limit
18.00 µg/L
CA MCL (no federal MCL): 10 µg/L · +20% over limit
Over CA MCLUCMR 3 Data
Strontium
Inorganic
Detected
390.0 µg/L
EPA Health Ref Level: 1,500 µg/L · 26% of limit
DetectedUCMR 3 Data
1,4-Dioxane
Organic
Detected
0.10 µg/L
EPA Health Advisory: 0.35 µg/L · 28% of limit
DetectedUCMR 3 Data
Manganese
Inorganic
Detected
9.5 µg/L
EPA Secondary MCL: 50 µg/L · 19% of limit
DetectedUCMR 4 Data
Vanadium
Inorganic
Over HA
48.00 µg/L
EPA Short-term HA: 21 µg/L · +20% over limit
Over Health AdvisoryUCMR 3 Data
Chlorate
Disinfection Byproduct
Detected
21.0 µg/L
EPA Lifetime HA: 210 µg/L · 10% of limit
DetectedUCMR 3 Data
Molybdenum
Inorganic
Detected
2.20 µg/L
EPA Lifetime HA: 40 µg/L · 6% of limit
DetectedUCMR 3 Data
Lithium
Inorganic
Detected
10.2 µg/L
State screening level: 60 µg/L · 17% of limit
DetectedNo federal MCLUCMR 5 Data (2023–2025)
PFAS Testing

Forever chemicals overview

National PFAS report →
30
Compounds tested
8
Detected
2
Exceed EPA MCL
5.33
Hazard Index
PFOS max: 0.0111 µg/L PFOA max: 0.0102 µg/L
Compliance Record

Violation summary

9
Total violations
2
Health-based
5
Active / unresolved
Oct 2024
Most recent violation
Compliance Record

Violations & advisories

9 Total
5 Active
2 Health-based
4 Resolved
Violations by category
Total Coliform Rule
3
Lead and Copper Rule Revisions
2
Consumer Confidence Rule
2
Nitrate Rule
1
Lead and Copper Rule
1
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Reporting
Reporting 0
Oct 2024 Active
LEAD AND COPPER RULE REVISIONS
Treatment Technique
Health-Based Health 0
Jul 2022 Active
Consumer Confidence Rule
Other Violation 0
Jul 2020 Active
Consumer Confidence Rule
Other Violation 0
Jul 1993 Active
Lead and Copper Rule
Monitoring & Reporting
Monitoring & Reporting 0
Jan 2021 Resolved
Nitrite
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2023
Dec 2010 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Dec 2010
Feb 2005 Resolved
Coliform (TCR)
Max Contaminant Level
Health-Based Health Resolved Feb 2005
Sep 1999 Resolved
Coliform (TCR)
Monitoring & Reporting
Monitoring & Reporting Resolved Sep 1999
Industrial pollution

Top industrial polluters within 10 miles of Hesperia

Industrial polluters nearby

Reported releases to surface water by facilities near Hesperia, ranked by pounds discharged annually.

Total reported releases to surface water: 0 lbs

FacilityTop chemicalTo surface water (lbs/yr)Distance
CHURCH & DWIGHT CO. INC.
Chemicals · CHURCH & DWIGHT CO INC
VICTORVILLE, CA92395
Lead06.3 mi
SHERWIN-WILLIAMS CO
Chemicals · THE SHERWIN-WILLIAMS CO
VICTORVILLE, CA92395
5.8 mi
3M OAK HILLS
Nonmetallic Mineral Product · 3M CO
OAK HILLS, CA92344
5.0 mi
W. R. GRACE
Chemicals · W R GRACE & CO
HESPERIA, CA92345
3.2 mi
HESPERIA PLANT 31
Nonmetallic Mineral Product · NA
HESPERIA, CA92345
2.3 mi

Source: EPA Toxic Release Inventory (TRI) 2023

Environmental Risk

Drought conditions

D1 — moderate drought

San Bernardino County is currently in D1 (moderate drought) per the U.S. Drought Monitor (week of May 5, 2026). Drought can elevate disinfection-byproduct (TTHM/HAA5) levels and taste/odor issues as utilities draw from lower reservoirs.

50.7%
Months in D2+ (last 30y)

Source: U.S. Drought Monitor, updated weekly by NDMC, USDA, and NOAA.

Environmental Risk

Flood & disaster history

10
Declared disasters
Mar 2023
Most recent
Flood
Most common type

San Bernardino County has experienced 10 federally declared disasters since 1980. Flooding and severe weather can compromise water treatment infrastructure and introduce contaminants into drinking water supplies.

Mar 2023
SEVERE WINTER STORMS, FLOODING, LANDSLIDES, AND MUDSLIDES
Flood FEMA #3592
Jan 2023
SEVERE WINTER STORMS, FLOODING, AND MUDSLIDES
Flood FEMA #3591
Jan 2011
SEVERE WINTER STORMS, FLOODING, AND DEBRIS AND MUD FLOWS
Flood FEMA #1952
Sep 2005
HURRICANE KATRINA EVACUATION
Hurricane FEMA #3248
Feb 1993
SEVERE WINTER STORM, MUD & LAND SLIDES, & FLOODING
Flood FEMA #979
Feb 1992
RAIN/SNOW/WIND STORMS, FLOODING, MUDSLIDES
Flood FEMA #935

Recommended water filters

Based on contaminants detected in Hesperia's water supply, we recommend the following filter types.

🧪
For PFAS
Reverse Osmosis or Activated Carbon Block
PFAS compounds exceed EPA maximum contaminant levels

Full contaminants report

Contaminant Detected Level EPA Limit Unit Category Status
Lead (90th percentile) 0.0 15 ppb Inorganic Safe
11Cl-PF3OUdS ND HI µg/L PFAS Not Detected
4:2 FTS ND HI µg/L PFAS Not Detected
6:2 FTS 0.050 HI µg/L PFAS Detected
8:2 FTS ND HI µg/L PFAS Not Detected
9Cl-PF3ONS ND HI µg/L PFAS Not Detected
ADONA ND HI µg/L PFAS Not Detected
HFPO-DA ND 0.01 µg/L PFAS Not Detected
lithium 10.200 HI µg/L PFAS Detected
NEtFOSAA ND HI µg/L PFAS Not Detected
NFDHA ND HI µg/L PFAS Not Detected
NMeFOSAA ND HI µg/L PFAS Not Detected
PFBA ND HI µg/L PFAS Not Detected
PFBS ND HI µg/L PFAS Not Detected
PFDA ND HI µg/L PFAS Not Detected
PFDoA ND HI µg/L PFAS Not Detected
PFEESA ND HI µg/L PFAS Not Detected
PFHpA 0.003 HI µg/L PFAS Detected
PFHpS ND HI µg/L PFAS Not Detected
PFHxA 0.005 HI µg/L PFAS Detected
PFHxS 0.011 HI µg/L PFAS Detected
PFMBA ND HI µg/L PFAS Not Detected
PFMPA ND HI µg/L PFAS Not Detected
PFNA ND HI µg/L PFAS Not Detected
PFOA 0.010 0.004 µg/L PFAS Over MCL
PFOS 0.011 0.004 µg/L PFAS Over MCL
PFPeA 0.004 HI µg/L PFAS Detected
PFPeS ND HI µg/L PFAS Not Detected
PFTA ND HI µg/L PFAS Not Detected
PFTrDA ND HI µg/L PFAS Not Detected
PFUnA ND HI µg/L PFAS Not Detected
Data source: EPA SDWIS, UCMR 5, local utility CCR.

Lead level trend (90th percentile)

EPA action level: 15 ppb
Lead has decreased by 5.0 ppb from 1992 (5.0 ppb) to 2025 (0.0 ppb).
Infrastructure

Water source & infrastructure

Primary Source
Groundwater
Operator
Local Government
Population Served
100,894
Water Systems
2
Water Source

Where Hesperia's water comes from

Groundwater

Hesperia's drinking water is drawn from underground aquifers through wells.

Groundwater is naturally filtered through rock and soil layers, generally requiring less treatment than surface water. However, it can contain naturally occurring contaminants like arsenic, radon, and minerals.

Agricultural activity, septic systems, and industrial operations near well fields can introduce nitrates, pesticides, and volatile organic compounds.

The system is operated by local government ownership and serves approximately 100,894 people through 2 water systems.

Local Hydrology

Water bodies near Hesperia

Hesperia is located near 2 notable water bodies. These water bodies contribute to the regional watershed and may indirectly affect groundwater quality.

Deep C Nr Hesperia
river
Wf Mojave R Ab Mojave R Forks Res Nr Hesperia
river
Infrastructure

Water systems serving Hesperia

System Name PWSID Population Source
HESPERIA WD CA3610024 100,744 GW
CALICO LAKE HOMEOWNERS CA3601036 150 GW
Regional Comparison

How Hesperia compares

Full California rankings →

Hesperia's score of 76.2/100 is above the average of 57/100 among major California cities. It outscores 7 of 10 nearby cities.

Hesperia (this city)
76.2
Oakland
77.9
San Diego
39.7
Sacramento
31.2
California avg
57
City Profile

About Hesperia, CA

Economic Profile
$67,698
Median Income
$337,619
Median Home Value
$1,436/mo
Median Rent
9.8%
Unemployment
Community
32.2
Median Age
531
People / sq mi
10.9%
College Educated
63.5%
Homeownership
Share this reportHelp others learn about their water quality
WhatsAppXFacebookLinkedInEmail

Frequently asked questions

Is Hesperia, CA tap water safe to drink?

Hesperia's water quality earned a grade of B (76.2/100). Some concerns have been identified. Consider a water filter for an extra layer of protection. The city ranks #442 out of 694 cities tested in California.

What contaminants are in Hesperia's water?

Lead was measured at 0.0 ppb (90th percentile). 8 PFAS compounds were detected. 9 violations are on record.

How is Hesperia's water quality grade calculated?

The grade is based on four factors: violation history (40%), lead and copper levels (25%), PFAS contamination (25%), and regulatory compliance (10%). The score is also adjusted based on how complete the available data is. See our methodology page for full details.

Do I need a water filter in Hesperia?

PFAS compounds exceed EPA limits — a reverse osmosis or activated carbon filter is recommended.

Where does Hesperia's water come from?

Hesperia's water is sourced from Groundwater. The city has 2 water systems serving approximately 100,894 residents.

What health violations has Hesperia's water system had?

Hesperia has 2 health-based violations on record. The most recent violation was recorded in October 2024. Health-based violations mean the water exceeded EPA maximum contaminant levels (MCLs) for a regulated substance. 5 violations remain unresolved.

Is Hesperia's groundwater at risk of contamination?

Hesperia uses groundwater, which can be affected by naturally occurring contaminants like arsenic, radon, and nitrate, as well as agricultural runoff and industrial activity. The system has 9 violations on record that may relate to groundwater quality. Groundwater systems are generally less susceptible to surface contamination but should be monitored for emerging contaminants like PFAS.

Why does Hesperia have so many PFAS compounds in its water?

8 different PFAS "forever chemical" compounds were detected in Hesperia's water supply during UCMR 5 testing. PFAS contamination often originates from proximity to military installations (AFFF firefighting foam), airports, industrial manufacturing sites, or wastewater treatment facilities. Some levels exceed the 2024 EPA maximum contaminant levels — a reverse osmosis or NSF-certified activated carbon filter is strongly recommended.

How does Hesperia's water compare to other cities?

Hesperia ranks #442 out of 694 cities in California (better than 36% of state cities) and #9348 out of 15744 cities nationally (41th percentile). The grade of B reflects the combined assessment of violation history, lead and copper levels, PFAS contamination, and regulatory compliance.